Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

MAP 0140 Setting the Screen (9516)



  Setting the Screen

 +---+
 |001|
 +---+
 - After you replace the main board or the display is attached
   to a different system unit, a slight vertical interference
   can be seen on the screen every four pixels. To remove this
   interference, do the following:
   1. Make sure that the system unit is turned on.
   2. Turn on the display and let it warm up for a while.
   3. Push the setup switch at the rear of the display.
   4. Do the following to get the setup menu:
      Be sure to these steps within a few seconds.

 

 
      a. Press both brightness arrow buttons at the same time.
      b. Press both contrast  arrow buttons at the same time.
      c. Press the brightness arrow (-) button.
         The DEBUG MENU ENABLED message appear on the screen.
   5. Repeatedly press the brightness arrow (-) button until
      the AMP G screen appears.
   6. Using the contrast arrow (-) or (+) button, adjust the
      value (±3) until the best quality of screen is obtained.
   7. Press the brightness arrow (-) button to go to the
      SUB MENU screen.
   8. Select SAVE and press the contrast arrow (-) button to
      save the change.
   9. Push the setup switch again to exit the setup menu.
 NOTE: See the "Installation and Operation Guide"
       for more information about the setup menu.


Back to  Jump to TOP-of-PAGE