LED | STATE |
---|---|
1 0 | On |
OK | On |
1 - 4 | see Note |
Wrap RI | On - If RI module is optical fiber Off - If RI module is copper |
Wrap RO | On - If RO module is optical fiber Off - If RO module is copper |
RI Module | On |
RO Module | On |
Error Code Display | Off |
Note If the base unit has an Optical Fiber Module installed, make sure that the optical fiber test
cable is inserted in the receptacles.
The green LED will be lit next to the number of each LAM that is connected to the base unit and is operating correctly.
The yellow LED will be lit next to the number of each LAM that is defective or incorrectly connected to the base unit.
+---+
|001|
+---+
Has the customer used the IBM Token-Ring Network Determination Guide
to isolate the problem to this IBM 8230 Base Unit ?
+---+
Yes No-+002|Refer the network administrator to the IBM Token-Ring
| +---+Network Problem Determination Guide to isolate the
| problem.
| Continue with Step 003 if you have isolated the
| problem to this IBM 8230.
+-+-+
|003|
+---+
- Check the 4/16 Mbps switch setting on the front of the base unit.
- Be sure that the setting matches the data rate of the ring.
- Turn on the power of the IBM 8230, and wait 60 seconds.
Note : DO NOT turn off the power of the base unit unless you
are instructed to do so. Turning off the power of the base unit
will disrupt all users connected to this base unit.
IS an X'8X' status code displayed in the error code display ?
+---+
Yes No-+004| Go to Step 006
| +---+
+-+-+
|005|
+---+
- Replace the Processor Board
- Test the IBM 8230 as described in this chapter (above the MAP)
+---+
|006|
+---+
Is an error code displayed ?
+---+
Yes No-+007| Go to Step 011
| +---+
+-+-+
|008|
+---+
Is the error code one of the following codes ?
20 2A 30 3A 31 3B
22 2C 32 3C 33 3D
24 2E 34 3E 35 3F
26 36 37
28 38 39
+---+
Yes No-+009| Locate the displayed Error Code in the below Table.
| +---+ Perform the action provided.
+-+-+
|010|
+---+
- LAM is not correctly connected to the base unit.
- LAM is defective.
- Processor Board is defective
- Power connector card is defective.
+---+
|011|
+---+
Are any of the LEDs lit ?
+---+
Yes No-+012| - Base units power switch is off.
| +---+ - AC voltage is missing at the wall outlet.
| - Power cord is not connected correctly.
| - AC voltage switch setting is incorrect.
| - Power Supply cable is not plugged into the
| Processor Board.
| - Display Card cable is not plugged into the
| Processor Board.
| - Power Supply is defective.
| - Processor Board is defective.
+-+-+ - Display card is defective.
|013|
+---+
Is the OK LED lit ?
+---+
Yes No-+014| Go to Step 018
+---+ +---+
|015|
+---+
Is the IBM 8230 Base Unit in a wrap state ?
Locate the RI and RO Wrap LEDs. If one or both of this LEDs is lit,
then the IBM 8230 Base Unit is in a wrap state of Wrap RI, Wrap RO,
or Wrap RI/RO.
+---+
Yes No-+016| Go to Step 021
+---+ +---+
|017|
+---+
- There is a problem with the token-ring network segment on the RI
or RO side of the IBM 8230 Base Unit.
- There is a problem with the Copper or Optical Fiber Module.
- There is a problem with the Processor Board.
- The IBM LAN Network Manager or Maintenance Facility has issued a
wrap command.
+---+
|018|
+---+
Are the Copper or Optical Fiber Module LEDs lit and no other LEDs lit ?
+---+
Yes No-+019| - Replace the Processor Board.
| +---+ - Test the IBM 8230 as described in this chapter
| (above the MAP)
+-+-+
|020|
+---+
- Replace the Display card
- Test the IBM 8230 as described in this chapter (above the MAP)
+---+
|021|
+---+
Is the LAM connected to the base unit, and is the LAM LED on the
front of the base unit off ?
+---+
Yes No-+022| Have soft errors been detected (e.g. by Ring Diags
| +---+ IBM LAN Manager, or some other program) ?
| +---+
| Yes No-+023| Notify the network administrator
| | +---+ that the IBM 8230 Base Unit is
| | operational.
| +-+-+
| |024| Anything internal to the IBM 8230 Base Unit
| +---+ but most likely the Processor Board is defective.
- Display card is defective.
- LAM is defective
- Processor Board is defective.
Error and Status Codes
Processor Board Error or Status Code.
Error Code in Hex | Type of Error or Status | Action |
---|---|---|
80-8F | Initialization in Progress | None |
90 | Error Stack Overflow | Test the 8230 |
E0 | Control Processor Error | Proc.-Board |
E4 | Control Processor Error | Proc.-Board |
E8 | Control Processor Error | Proc.-Board Power-Supply |
EC | Control Processor Error | Proc.-Board |
F4 | Internal Hardware Error | Wrap-Plug Media-Filter |
F8 | Controlled Access Unit Check | Proc.-Board |
Remote Program Update Error or Status Codes.
Error Code in Hex | Type of Error or Status | Action |
---|---|---|
11 | Finding Microcode Loader | none |
12 | Transferring Microcode Data | none (20 minutes) |
13 | Microcode Update complete | none |
14 | Microcode Update Alert | none |
A1 | Microcode Checksum Error | correct u-code ? |
A2 | Microcode Loader Not Found | reload u-code |
A3 | Microcode Update File Not Found | correct u-code ? |
A4 | Unsuccessful Microcode Load | correct u-code ? |
Medium Access Control (MAC) Processor Error Codes.
(Reseat all Processorboard components / check Voltage)
Error Code in Hex | Type of Error or Status |
---|---|
61-63 | 8230 Adapter Error (1st MAC Error) |
65-67 | 8230 Adapter Error (1st MAC Error) |
69-6B | 8230 Adapter Error (1st MAC Error) |
6D-6F | 8230 Adapter Error (1st MAC Error) |
71-73 | 8230 Adapter Error (1st MAC Error) |
75-77 | MAC Toggle Error (1st MAC Error) |
E1-E3 | 8230 Adapter Error (2nd MAC Error) |
E5-E7 | 8230 Adapter Error (2nd MAC Error) |
E9-EB | 8230 Adapter Error (2nd MAC Error) |
ED-EF | 8230 Adapter Error (2nd MAC Error) |
F1-F3 | 8230 Adapter Error (2nd MAC Error) |
F5-F7 | MAC Toggle Error |
Lobe Attachment Module Error Codes.
(Reseat all Processorboard components / check Voltage / run Test
if still same error, then replace the Processor Board.)
Error Code in Hex | Type of Error |
---|---|
20 | Lobe Attachment Module 1 Ring Data Error |
21 | Lobe Attachment Module 1 Cable Mismatch |
22 | Lobe Attachment Module 1 Communication Error |
24 | Lobe Attachment Module 2 Ring Data Error |
25 | Lobe Attachment Module 2 Cable Mismatch |
26 | Lobe Attachment Module 2 Communication Error |
28 | Lobe Attachment Module 3 Ring Data Error |
29 | Lobe Attachment Module 3 Cable Mismatch |
2A | Lobe Attachment Module 3 Communication Error |
2C | Lobe Attachment Module 4 Ring Data Error |
2D | Lobe Attachment Module 4 Cable Mismatch |
2E | Lobe Attachment Module 4 Communication Error |
30 | Lobe Attachment Module 1 Defective |
31 | Lobe Attachment Module 1 Defective |
32 | Lobe Attachment Module 1 Defective |
33 | Lobe Attachment Module 1 Defective |
34 | Lobe Attachment Module 2 Defective |
35 | Lobe Attachment Module 2 Defective |
36 | Lobe Attachment Module 2 Defective |
37 | Lobe Attachment Module 2 Defective |
38 | Lobe Attachment Module 3 Defective |
39 | Lobe Attachment Module 3 Defective |
3A | Lobe Attachment Module 3 Defective |
3B | Lobe Attachment Module 3 Defective |
3C | Lobe Attachment Module 4 Defective |
3D | Lobe Attachment Module 4 Defective |
3E | Lobe Attachment Module 4 Defective |
3F | Lobe Attachment Module 4 Defective |
External Error Codes.
Error Code in Hex | Type of Error | Action |
---|---|---|
03 | Ring Error Not Found | Proc.-Board |
05 | Frame Buffer Congestion | none |
07 | Internal Ring Recovery in Progress | none |
B0 | Duplicate Address MAC PO | check address |
B1 | Duplicate Address MAC PI | check address |
B2 | Duplicate Address MAC S | check address |
Please see the LEGAL - Trademark notice.