Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Numeric Error Codes (8650)



Error Codes

Error Code    FRU/Action.
  
0002 1. Cables
(Primary boot device not found) 2. Primary Boot Device
  
0010 1. Processor Module
(Cache memory failure, 2. Processor Board
do not enable cache)
0015 1. Primary Output Device
(Primary output device
not found)
0016 1. Primary Input Device
(Primary input device
not found)
0041 1. Reseat EISA Adapter
(EISA ID mismatch for slot) 2. Run SCU program
  3. EISA Adapter
  
0043 1. Reseat EISA Adapter
(EISA invalid configuration 2. Run SCU program
for slot)
0044 1. Reseat EISA Adapter
(EISA configuration not assured) 2. Run SCU program
  
0045 1. Reseat EISA Adapter
(EISA expansion board not 2. EISA Adapter
ready in slot) 3. System Board
  
0047 1. Run SCU program
(EISA CMOS configuration not set) 2. EISA Adapter
  3. System Board
  
0048 1. Run SCU program
(EISA CMOS checksum failure) 2. System Board
  
0049 1. Run SCU program
(EISA NVRAM invalid) 2. System Board
  
0060 1. Unlock keyboard
(Keyboard is locked - 2. Keyboard
- please unlock it) 3. System Board
  
0070 1. Set time and date
(CMOS time and date not set) 2. Real-Time Clock Module
  
0080 1. Reseat adapter
(Option ROM has bad checksum) 2. Adapter
  
0083 1. Reseat adapter
(Shadow of PCI ROM failed) 2. Adapter
  
0084 1. Reseat adapter
(Shadow of EISA ROM failed) 2. Adapter
  
0085 1. Reseat adapter
(Shadow of ISA ROM failed) 2. Remove adapter
  
0131 1. Cable
(Floppy Drive A:) 2. Drive
  
0132 1. Cable
(Floppy Drive B:) 2. Drive
  
0135 1. System Board
(Floppy disk controller
failed)
0140 1. Reboot system
(Shadow of system BIOS 2. System Board
failed)
0171 1. Reseat processor module
(CPU failure - 2. Processor Module
- Slot 1, CPU # 1) 3. Processor Board
  
0172 1. Reseat processor module
(CPU failure - 2. Processor Module
- Slot 1, CPU # 2) 3. Processor Board
  
0173 1. Reseat processor module
(CPU failure - 2. Processor Module
- Slot 2, CPU # 1) 3. Processor Board
  
0174 1. Reseat processor module
(CPU failure - 2. Processor Module
- Slot 2, CPU # 2) 3. Processor Board
  
0175 1. Use compatible processor modules
(CPU modules are
incompatible)
0176 0178 0180 1. see FALSE CPU FAILURE AT POST
0177 0179 0181
0180 1. Processor Module
(Attempting to boot
with failed CPU)
0191 1. Real-Time Clock Module
(CMOS battery failed) 2. System Board
  
0195 1. Run SCU program
(CMOS system options not set)
0198 1. Run SCU program
(CMOS checksum invalid)
0289 1. Run System Setup
(System memory size mismatch) 2. Memory SIMM
  3. Memory Board
  
0295 1. Memory SIMM
(Address line short detected) 2. Memory Board
  
0297 1. Run System Setup
(Memory size decreased) 2. Memory SIMM
  3. Memory Board
  
0299 1. Reseat memory and memory board
(ECC error correction failure) 2. Memory Board
  3. System Board
  
0301 1. Reseat memory and memory board
(ECC single bit correction 2. Memory Board
failed, correction disabled) 3. System Board
  
0302 1. Reseat memory and memory board
(ECC double bit error) 2. Memory Board
  3. System Board
  
0310 1. Reseat memory and memory board
(ECC address failure 2. Memory Board
  3. System Board
  
0370 1. Reboot system
(Keyboard controller error) 2. System Board
  
0373 1. Ensure nothing is resting on the keyboard
(Keyboard stuck key detected) 2. Keyboard
  
0375 1. Swap keyboard and mouse
(Keyboard and mouse swapped)
0380 1. Replace memory as indicated
(ECC SIMM failure,
board is in slot 1)
0392 1. Replace memory as indicated
(ECC SIMM failure,
board is in slot 2)
0430 1. System Board
(Timer channel 2 failure)
0440 1. System Board
(Gate-A20 failure)
0441 1. Use correct device driver
(Unexpected interrupted
in protected mode)
0445 1. System Board
(Master interrupt controller
error)
0446 1. System Board
(Slave interrupt controller
error)
0450 1. System Board
(Master DMA controller error)
0451 1. System Board
(Slave DMA controller error)
0460 1. Adapter
(Fail-safe timer NMI failure) 2. System Board
  
0461 1. Check software/device driver
(Software port NMI failure)
0465 1. Check adapter
(Bus timeout NMI in slot) 2. Adapter
  3. System Board
  
0467 1. Check adapter
(Expansion board NMI in slot) 2. Adapter
  
0501 1. System Board
(PCI system error) 2. Adapter
  
0510 1. PCI device
(PCI parity error) 2. System Board
  
0710 1. Run SCU program
(System board device
resource conflict)
0711 1. Run SCU program
(Static device resource
conflict)
0800 1. Run SCU program
(PCI I/O port conflict)
0801 1. Run SCU program
(PCI memory conflict)
0802 1. Run SCU program
(PCI IRQ conflict)
0803 1. Rerun diagnostics
(PCI error log is full,
the log will be cleared
automatically)
0810 1. Run SCU program
(Floppy disk controller
resource conflict)
0811 1. Check cables
  2. System Board
  
0812 1. Check cables
  2. System Board
  
0815 1. Run SCU program
(Parallel port resource
conflict)
0816 1. Run SCU program
(Serial port 1 resource
conflict)
0817 1. Run SCU program
(Serial port 2 resource
conflict)
0820 1. Run SCU program
(Expansion board disabled 2. Adapter
in slot) 3. System Board
  
0900 1. Run SCU program
(NVRAM checksum error,
NVRAM cleared)
0903 1. Run SCU program
(NVRAM DATA invalid,
NVRAM cleared)
0905 1. Run SCU program
(NVRAM cleared by jumper)
0960 1. see FALSE CPU FAILURE AT POST
Watchdog Timeout has occurred
0982 1. Adapter
(I/O expansion board 2. System Board
NMI in slot)
0984 1. Run SCU program
(Expansion board disabled 2. Adapter
in slot) 3. System Board
  
0985 1. Adapter
(Fail-safe timer NMI) 2. System Board
  
0986 1. Adapter
(System reset caused 2. System Board
by Watchdog Timer)
0987 1. Adapter
(Bus timeout NMI in slot) 2. System Board


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.