Error Code | FRU/Action. |
---|---|
0002 | 1. Cables |
(Primary boot device not found) | 2. Primary Boot Device |
0010 | 1. Processor Module |
(Cache memory failure, | 2. Processor Board |
do not enable cache) | |
0015 | 1. Primary Output Device |
(Primary output device | |
not found) | |
0016 | 1. Primary Input Device |
(Primary input device | |
not found) | |
0041 | 1. Reseat EISA Adapter |
(EISA ID mismatch for slot) | 2. Run SCU program |
3. EISA Adapter | |
0043 | 1. Reseat EISA Adapter |
(EISA invalid configuration | 2. Run SCU program |
for slot) | |
0044 | 1. Reseat EISA Adapter |
(EISA configuration not assured) | 2. Run SCU program |
0045 | 1. Reseat EISA Adapter |
(EISA expansion board not | 2. EISA Adapter |
ready in slot) | 3. System Board |
0047 | 1. Run SCU program |
(EISA CMOS configuration not set) | 2. EISA Adapter |
3. System Board | |
0048 | 1. Run SCU program |
(EISA CMOS checksum failure) | 2. System Board |
0049 | 1. Run SCU program |
(EISA NVRAM invalid) | 2. System Board |
0060 | 1. Unlock keyboard |
(Keyboard is locked - | 2. Keyboard |
- please unlock it) | 3. System Board |
0070 | 1. Set time and date |
(CMOS time and date not set) | 2. Real-Time Clock Module |
0080 | 1. Reseat adapter |
(Option ROM has bad checksum) | 2. Adapter |
0083 | 1. Reseat adapter |
(Shadow of PCI ROM failed) | 2. Adapter |
0084 | 1. Reseat adapter |
(Shadow of EISA ROM failed) | 2. Adapter |
0085 | 1. Reseat adapter |
(Shadow of ISA ROM failed) | 2. Remove adapter |
0131 | 1. Cable |
(Floppy Drive A:) | 2. Drive |
0132 | 1. Cable |
(Floppy Drive B:) | 2. Drive |
0135 | 1. System Board |
(Floppy disk controller | |
failed) | |
0140 | 1. Reboot system |
(Shadow of system BIOS | 2. System Board |
failed) | |
0171 | 1. Reseat processor module |
(CPU failure - | 2. Processor Module |
- Slot 1, CPU # 1) | 3. Processor Board |
0172 | 1. Reseat processor module |
(CPU failure - | 2. Processor Module |
- Slot 1, CPU # 2) | 3. Processor Board |
0173 | 1. Reseat processor module |
(CPU failure - | 2. Processor Module |
- Slot 2, CPU # 1) | 3. Processor Board |
0174 | 1. Reseat processor module |
(CPU failure - | 2. Processor Module |
- Slot 2, CPU # 2) | 3. Processor Board |
0175 | 1. Use compatible processor modules |
(CPU modules are | |
incompatible) | |
0176 0178 0180 | 1. see FALSE CPU FAILURE AT POST |
0177 0179 0181 | |
0180 | 1. Processor Module |
(Attempting to boot | |
with failed CPU) | |
0191 | 1. Real-Time Clock Module |
(CMOS battery failed) | 2. System Board |
0195 | 1. Run SCU program |
(CMOS system options not set) | |
0198 | 1. Run SCU program |
(CMOS checksum invalid) | |
0289 | 1. Run System Setup |
(System memory size mismatch) | 2. Memory SIMM |
3. Memory Board | |
0295 | 1. Memory SIMM |
(Address line short detected) | 2. Memory Board |
0297 | 1. Run System Setup |
(Memory size decreased) | 2. Memory SIMM |
3. Memory Board | |
0299 | 1. Reseat memory and memory board |
(ECC error correction failure) | 2. Memory Board |
3. System Board | |
0301 | 1. Reseat memory and memory board |
(ECC single bit correction | 2. Memory Board |
failed, correction disabled) | 3. System Board |
0302 | 1. Reseat memory and memory board |
(ECC double bit error) | 2. Memory Board |
3. System Board | |
0310 | 1. Reseat memory and memory board |
(ECC address failure | 2. Memory Board |
3. System Board | |
0370 | 1. Reboot system |
(Keyboard controller error) | 2. System Board |
0373 | 1. Ensure nothing is resting on the keyboard |
(Keyboard stuck key detected) | 2. Keyboard |
0375 | 1. Swap keyboard and mouse |
(Keyboard and mouse swapped) | |
0380 | 1. Replace memory as indicated |
(ECC SIMM failure, | |
board is in slot 1) | |
0392 | 1. Replace memory as indicated |
(ECC SIMM failure, | |
board is in slot 2) | |
0430 | 1. System Board |
(Timer channel 2 failure) | |
0440 | 1. System Board |
(Gate-A20 failure) | |
0441 | 1. Use correct device driver |
(Unexpected interrupted | |
in protected mode) | |
0445 | 1. System Board |
(Master interrupt controller | |
error) | |
0446 | 1. System Board |
(Slave interrupt controller | |
error) | |
0450 | 1. System Board |
(Master DMA controller error) | |
0451 | 1. System Board |
(Slave DMA controller error) | |
0460 | 1. Adapter |
(Fail-safe timer NMI failure) | 2. System Board |
0461 | 1. Check software/device driver |
(Software port NMI failure) | |
0465 | 1. Check adapter |
(Bus timeout NMI in slot) | 2. Adapter |
3. System Board | |
0467 | 1. Check adapter |
(Expansion board NMI in slot) | 2. Adapter |
0501 | 1. System Board |
(PCI system error) | 2. Adapter |
0510 | 1. PCI device |
(PCI parity error) | 2. System Board |
0710 | 1. Run SCU program |
(System board device | |
resource conflict) | |
0711 | 1. Run SCU program |
(Static device resource | |
conflict) | |
0800 | 1. Run SCU program |
(PCI I/O port conflict) | |
0801 | 1. Run SCU program |
(PCI memory conflict) | |
0802 | 1. Run SCU program |
(PCI IRQ conflict) | |
0803 | 1. Rerun diagnostics |
(PCI error log is full, | |
the log will be cleared | |
automatically) | |
0810 | 1. Run SCU program |
(Floppy disk controller | |
resource conflict) | |
0811 | 1. Check cables |
2. System Board | |
0812 | 1. Check cables |
2. System Board | |
0815 | 1. Run SCU program |
(Parallel port resource | |
conflict) | |
0816 | 1. Run SCU program |
(Serial port 1 resource | |
conflict) | |
0817 | 1. Run SCU program |
(Serial port 2 resource | |
conflict) | |
0820 | 1. Run SCU program |
(Expansion board disabled | 2. Adapter |
in slot) | 3. System Board |
0900 | 1. Run SCU program |
(NVRAM checksum error, | |
NVRAM cleared) | |
0903 | 1. Run SCU program |
(NVRAM DATA invalid, | |
NVRAM cleared) | |
0905 | 1. Run SCU program |
(NVRAM cleared by jumper) | |
0960 | 1. see FALSE CPU FAILURE AT POST |
Watchdog Timeout has occurred | |
0982 | 1. Adapter |
(I/O expansion board | 2. System Board |
NMI in slot) | |
0984 | 1. Run SCU program |
(Expansion board disabled | 2. Adapter |
in slot) | 3. System Board |
0985 | 1. Adapter |
(Fail-safe timer NMI) | 2. System Board |
0986 | 1. Adapter |
(System reset caused | 2. System Board |
by Watchdog Timer) | |
0987 | 1. Adapter |
(Bus timeout NMI in slot) | 2. System Board |
Please see the LEGAL - Trademark notice.