Temperature
- System on: +5° to +35°C (+41° to +95°F)
derated 0.5° for every 1000 ft (305 m) above sea level
- System off: -40° to +70° C (-40° to +157° F)
Humidity
- System on: 85% noncondensing at +40° C <33°
wetbulb (at 40° C ambient) (no peripherals)
- System off: 95% noncondensing at 55° C (131° F)
Thermal shock
- System-off: -40° to 70° C (-40° to 158° F)
Random vibration
System off:
- 7 to 8 Hz, 0.001 to 0.01 G2 per Hz
- 28 to 500 Hz, 0.01 G2 per Hz Random input,
0.01 g2/Hz at 5 Hz, sloping to 0.02 g2/Hz from 20 Hz to 500 Hz.
Mechanical shock
- System off: 30.0 G (with cosmetic damage)
- System on: 2.0 G with 11 msec duration, 1/2 sine wave 50 g,
11 ms, 1/2 sine Not applicable
Altitude
- System off: 0 to 50,000 ft (15,240 m)
- System on: 0 to 50,000 ft (15,240 m)
Electrostatic discharge
- System on: Tested to 20 KV
Acoustic noise
- Less than 45 dBA at +65° to = 75° F
Safety
- UL 1950
- CSA 22.2 No. 950 by TUV
- IEC 950 by TUV
- EN 60950 and Nordic deviations by NEMKO
Electromagnetic emissions
- Certified to FCC 47 Class B,
Test's, CISPR 22/85 Class B, EN 55022: Registered with VCCI
Immunity
- Verified to comply with EN 50082-2
Please see the LEGAL - Trademark notice.