Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Specifications (Environmental 8650)



Specifications (Environmental)

 Temperature
   - System on:    +5° to +35°C (+41° to +95°F)
                   derated 0.5° for every 1000 ft (305 m) above sea level
   - System off:   -40° to +70° C (-40° to +157° F)
 Humidity
   - System on:     85% noncondensing at +40° C <33°
                    wetbulb (at 40° C ambient) (no peripherals)
   - System off:    95% noncondensing at 55° C (131° F)
 Thermal shock
   - System-off:    -40° to 70° C (-40° to 158° F)
 Random vibration
 System off:
   - 7  to 8 Hz, 0.001 to 0.01 G2 per Hz
   - 28 to 500 Hz, 0.01 G2 per Hz Random input,
     0.01 g2/Hz at 5 Hz, sloping to 0.02 g2/Hz from 20 Hz to 500 Hz.
 Mechanical shock
   - System off:    30.0 G (with cosmetic damage)
   - System on:      2.0 G with 11 msec duration, 1/2 sine wave 50 g,
                           11 ms, 1/2 sine Not applicable
 Altitude
   - System off:    0 to 50,000 ft (15,240 m)
   - System on:     0 to 50,000 ft (15,240 m)
 Electrostatic discharge
   - System on:     Tested to 20 KV
 Acoustic noise
   - Less than 45 dBA at +65° to = 75° F
 Safety
   - UL 1950
   - CSA 22.2 No. 950 by TUV
   - IEC 950 by TUV
   - EN 60950 and Nordic deviations by NEMKO
 Electromagnetic emissions
   - Certified to FCC 47 Class B,
     Test's, CISPR 22/85 Class B, EN 55022: Registered with VCCI
 Immunity
   - Verified to comply with EN 50082-2


Back to  Jump to TOP-of-PAGE
More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.