IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
General Checkout (QAPlus/PRO)
General Checkout (QAPlus/PRO)
This general checkout procedure is for computers that are supported by the QAPlus/PRO Diagnostics test.
Diagnostic error messages appear when a test program finds a problem with a hardware option. For the test program to properly
determine if a test Passed, Failed, or Aborted , the test programs check the error-return code at test completion. (See
'Return Codes').
General error messages appear if a problem or conflict is found by an application program, the operating system, or both. For an
explanation of these messages, refer to the information supplied with that software package.
NOTE:
- If multiple error codes are displayed, diagnose the first error code displayed.
- If the computer hangs with a POST error, go to the 'Symptom-to-FRU Index' for the system you are servicing. (see below table)
- If the computer hangs and no error is displayed, go to Undetermined Problems (in the PS/2 Hardware Maintenance manual).
- If a device cannot be select from the Module Test menu, that device may be defective.
- For (Server 704) Mylex RAID adapter error codes see 'Mylex RAID Adapter Error Codes'
For information on the RAID adapter messages, and for other information on troubleshooting a disk-array, see the Mylex booklets that were
shipped with the server.
See also How to Navigate - QAPlus
+---+
|001|
+---+
- Power-off the computer and all external devices.
- Check all cables and power cords.
- Set all display controls to the middle position.
- Insert the QAPlus/PRO Diagnostics diskette into drive A.
- Power-on all external devices.
- Power-on the computer
- Check for the following responses:
- One beep.
- Readable instructions or the Main Menu.
DID YOU RECEIVE THE CORRECT RESPONSES ?
+---+
Yes No-+002| Find the failure symptom in
+-+-+ +---+ the 'Symptom-to-FRU Index' for the system you
|003| are servicing. (see below table)
+---+
Run the Advanced Diagnostic Test. If necessary, refer to
'QAPlus/PRO Diagnostics'
If you receive an error, go to the 'Symptom-to-FRU Index'
for the system you are servicing. (see below table)
Symptom-to-FRU Index Table for Machine / Type:
Back to
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.