RDDDPLSCB QEET
|--+||||| |-+|
| |||||| | |+--- Test state
| |||||| | +---- Error code Extension
| |||||| +------ Qualifier
| ||||||
| |||||+-------- Bus (0=internal 1=external)
| ||||+--------- Capacity of the device
| |||+---------- Slot number of the device
| ||+----------- LUN (usually 0)
| |+------------ PLUN (SCSI ID #)
| |
| +------------- Device Number
+---------------- Reserved Digit (usually 0)
As an example, if you have SCSI error code 021050A0, each digit decodes as follows:
Digit | Information |
---|---|
0 | Reserved digit (usually 0) |
210 | Device number 210 indicates hard disk |
5 | SCSI ID assigned is 5 |
0 | Logical Unit Number (not used, usually 0) |
A | The device capacity is 60MB (A=60MB) |
0 | The device is connected to the internal bus |
RDDD Codes for Adapters
RDDD | Device Type or Information |
---|---|
0037 | SCSI on the System board |
0096 | SCSI adapter with cache |
0112 | SCSI adapter w/o cache |
0206 | SCSI-2 adapter |
RDDD Codes for Devices
RDDD | Device Type or Information |
---|---|
0208 | Unknown device type |
0209 | Direct access - removable media, and/or other than 512 byte blocks |
0210 | Direct access - hard disk, 512 byte blocks |
0211 | Sequential access (tape) |
0212 | Printer |
0213 | Processor |
0214 | Write Once, Read Multiple (W.O.R.M.) |
0215 | Read only (CD-ROM) |
0216 | Scanner |
0217 | Optical Memory (read/write optical disk) |
0218 | Changer (multiple tray CD-ROM) |
0219 | Communications |
B Codes
B | Device Type or Information |
---|---|
0 | Dual SCSI adapter (internal bus) |
1 | Dual SCSI adapter (external bus) |
QEET 0000 Codes
PLSC | QEET | Information |
---|---|---|
0100 | 0000 | On systems with NVRAM, SCSI setup data not located, or the checksum did not verify. On systems w/o NVRAM (Model 8550 for example), setup data must be on the 1st hard disk. |
0200 | 0000 | Configuration error. No hard disk found at PUN 6, LUN 0 for 161, 162, 165 system error path. Might be an unsupported configuration. |
0300 | 0000 | No space available in extended BIOS data area for SCSI data table (possibly to many adapters installed). |
0400 | 0000 | ROM modules not found on adapter (IML based systems only). Running setup might correct it. |
0500 | 0000 | ROM checksum error on 2nd 16K portion of 32K ROM |
0600 | 0000 | ROM access control port error |
QEET Errors (other than 0000)
These are specific QEET error codes (preceded by a DDD indicating an adapter).
NOTE:
A number in slot S indicates an error on the adapter, (or device
attached to the adapter) in slot S If S is 0, suspect the system board.
QEET | Information |
---|---|
001x | 8032/80188/80C186 ROM test failure |
002x | Local RAM test failure |
003x | Bad fuse, or bad termination, or local RAM address failure on SCSI adapter if RDDD is 0112. |
004x | Internal peripheral test failure |
005x | Buffer control chip test failure, or LTB failed, (or system-board SCSI failed if RDDD is 0037. |
006x | Undefined error condition, or buffer RAM test failure on SCSI adapter if RDDD is 0096 |
007x | System interface control chip test failure |
008x | SCSI internal interface test failed |
00Ax | SCSI external interface test failed |
107x | Adapter hardware failure |
10Cx | Command failed |
10Ex | Command error (invalid command or parameter) |
10Fx | Sequencing error |
110x | Adapter internal error log contains entries. (Reported if no other errors on adapter exist.) |
180x | Time out |
181x | Adapter busy error |
182x | Unexpected interrupt presented by adapter |
183x | Adapter register test failure |
184x | Adapter reset failure |
185x | Adapter buffer test failure (on cached adapters) |
186x | Adapter reset count expired |
187x | Adapter registers not cleared on reset |
188x | Card ID in adapter microcode did not match ID in POS registers |
190x | Expected device did not respond |
19Yx | DMA arbitration level conflict (Y=assigned arbitration level) |
220x | Adapter hardware error |
221x | Global timeout on adapter (device did not respond) |
222x | Adapter DMA error |
223x | Adapter buffer defective |
224x | Command aborted by adapter |
301x | Invalid parameter in SCB |
303x | Command not supported |
304x | Command aborted by system |
305x | Command rejected (buffer not disabled) |
306x | Command rejected (Adapter diagnostic failure) |
307x | Format rejected |
308x | Assign rejected (command in process) |
309x | Assign rejected (device already assigned) |
30Ax | Command rejected (device not assigned) |
30Bx | Command rejected (maximum LBA exceeded) |
30Cx | Command rejected (16 bit card slot address range exceeded) |
313x | Invalid device for command |
3FFx | Status not returned by adapter |
401x | Recovered error (not an error condition) |
402x | Device not ready |
403x | Device medium error |
404x | Device hardware error |
405x | Illegal request for device |
406x | Device unit attention would not clear |
407x | Device data protect error |
409x | Device vendor unique error |
40Ax | Copy operation aborted by device |
40Bx | Device command aborted |
40Cx | Device search data command satisfied |
40Dx | Device volume overview (residual data remains in buffer) |
40Ex | Device mismatch (source data did not match medium data) |
500x | Check condition on device, no sense data returned |
501x | No index or sector |
502x | Seek incomplete |
503x | Write fault |
504x | Drive not ready |
505x | Drive not selected |
506x | No track zero found |
507x | Multiple drives selected |
508x | Logical unit communication failure |
509x | Head positioning error (track following error) |
510x | CRC or ECC error in ID field |
511x | Unrecoverable read error |
512x | No address mark (ID field) |
512x | No address mark (data field) |
514x | Record not found |
515x | Seek error |
516x | Data synchronization error |
517x | Recoverable read error |
518x | ECC recovered read error |
519x | Defect list error |
51Ax | Parameter overrun |
51Bx | Synchronous transfer error |
51Cx | Primary defect list not found |
51Dx | Compare error |
520x | Invalid command |
521x | Illegal logical block address (LBA) |
522x | Illegal function for device type |
524x | Illegal command block field |
525x | Invalid LUN |
526x | Illegal field in parameter list |
528x | Media changed |
529x | Power-on or bus device reset occurred (not an error) |
52Ax | Mode select parameters changed (not an error) |
531x | Media format corrupted |
532x | Defect spare location unavailable |
540x | Device RAM failure |
541x | Data path diagnostic failure |
542x | Power-on diagnostic failure |
543x | Message rejected |
544x | Internal controller error |
545x | Device was unable to reconnect |
547x | Interface parity error |
548x | Initiator detected error |
549x | Illegal command or command out of sequence error |
5F0x | Format in progress (not an error) |
5F1x | Spinup in progress |
601x | SCSI bus reset occurred |
602x | SCSI interface fault |
610x | Selection timeout error (device not available) |
611x | Unexpected bus free |
612x | Mandatory SCSI message rejected |
613x | Invalid SCSI phase sequence |
620x | Short length record error |
702x | Device not ready (removable media devices) |
704x | Device not ready (non removable media devices) |
728x | Media changed error would not clear |
731x | Medium format corrupted (format unit interrupted - format must be issued again) |
7F0x | Format in progress (prior format unit issued being completed) |
7F1x | Spinup in progress |
Q Codes
All error codes with Q = 1 are developed using information returned by either an adapter or
device. The Q value defines the origin of the EE code that is reported.
Error codes (EE) with Q = 4 or 5 may be reported that are not listed here or can actually have
a definition other than that given, depending on the device.
Q | Information |
---|---|
2 | Command error field of command complete status block returned by the adapter |
3 | SCSI Status field of the command complete status block or command error field values indicating software problems (<20H) |
4 | Sense key value returned by a device |
5 | Additional sense byte (byte 12) of sense information from device |
6 | Device error code field of command complete status block |
7 | Device errors not normally considered an error, but considered an error based on when the code was returned (medium corrupted error on device with non removable media) |
Test Status Codes
T | Information |
---|---|
O | Not applicable for error code |
A | Adapter initialization error |
B | Adapter reset |
C | Adapter register test |
D | Adapter buffer test phase 1 (on cached adapters) |
E | Adapter buffer test phase 2 (on cached adapters) |
F | Adapter buffer test phase 3 (on cached adapters) |
G | Adapter buffer test phase 4 (on cached adapters) |
H | Adapter (buffer enable, buffer size, retry, enable) |
I | Device assignment sequence |
J | Device not ready (initial unit attention clearing) |
K | Device reset |
L | Device starting phase |
M | Device in process of starting |
N | Device block size determination |
O | Device self-test |
P | Device single block read (LBA) |
Q | Device double block read (LBA) |
S | Error occurred after device testing completed |
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.