IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
Multiprocessor Error Indication (IP and FP Codes)
Multiprocessor Error Indication (IP and FP Codes)
During the early POST code, various multiprocessor bus errors might occur, if they do, the early POST code will display error
information to the information panel in one of the following formats:
IP:1XX D SXX
FP:1XX D SXX
D Character denoting the type of board/card issuing the error as follows.
C for Processor Card
M for Memory Card
B for Bridge Card
S Slot number of the board/card issuing the error
If you receive an IP or FP error, do the following.
- Replace the board/card issuing the error.
- If replacing a FRU does not correct the problem, reinstallthe FRU you removed from the computer, then,
continue with the next step.
- Remove all cards/boards of the same type identified by the error code one at a time until you locate the
failing card/board. (Example, if the error code identified a memory card and replacing the memory card in the
slot identified by the error codedoes not correct the problem, remove all memory cards one at a time until you locate
the failing board)
If the problem remains, replace the FRUs in the following order.
- Memory Card
- Processor Card
- Bridge Card
- System Board
Back to
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.