Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Checkpoint Codes (CP)



Checkpoint Codes (CP)

The following checkpoints are be displayed on the information panel during early portions of the Power-On Self-Test (POST) code. If the system hangs with one of these checkpoints displayed, the FRU replacement should be as listed with the first FRU being the first item and so on.

The checkpoint code information is displayed on the information panel in the following format:

CP:1XX 1XX  = Checkpoint values

NOTE:

CP Code    FRU
141 1. System Board
Start of COM 1 Test 2. Bridge Card
  3. Default Processor Card
  
142 1. Memory Card
Start of SRAM Test 2. Bridge Card
  3. Default Processor Card
  4. System Board
  
143 1. Memory Card
SRAM Test 2. Default Processor Card
  3. System Board
  
144 1. Memory Card
SRAM Test 2. Default Processor Card
  3. System Board
  
145 1. Memory Card
SRAM Test 2. Default Processor Card
  3. System Board
  
146 1. Default Processor Card
Transition to Protected Mode 2. Bridge Card
  3. System Board
  
147 1. Default Processor Card
Port Initialization 2. Bridge Card
  3. System Board
  
148 1. Default Processor Card
Jump to 32-Bit Assembly 2. Bridge Card
Code 3. Memory Card
  4. System Board
  
149 1. Default Processor Card
Execution of 32-Bit 2. Bridge Card
Protected Mode 3. Memory Card
  4. System Board
  
14A 1. Default Processor Card
Transition to 'C' Code 2. Bridge Card
  3. System Board
  
14C 1. Default Processor Card
Default Processor Card 2. Bridge Card
Setup Routines 3. System Board
  
14D 1. Default Processor Card
Additional Default Processor 2. Bridge Card
Card Setup Routines 3. System Board
  
14E 1. Default Processor Card
Additional Default Processor 2. Bridge Card
Card Setup Routines 3. System Board
  
14F 1. Default Processor Card
Additional Default Processor 2. Bridge Card
Card Setup Routines 3. System Board
  
150 1. System Board
ROM Checksum 2. Bridge Card
  3. Default Processor Card
  
151 1. Default Processor Card
L2 Cache Flush on Default 2. Bridge Card
Processor Card 3. Memory Card
  4. System Board
  
152 1. Default Processor Card
Default Processor Card 2. Bridge Card
Configuration 3. System Board
  
153 1. Default Processor Card
Default Processor Card and 2. Bridge Card
Bridge Card Initialization 3. System Board
  
154 1. Bridge Card
Bridge DMA Initialization 2. System Board
  3. Default Processor Card
  4. Memory Card
  
155 1. Default Processor Card
Enable Fault/Error Detection 2. Bridge Card
and Enable Interrupts 3. System Board
  
156 1. Default Processor Card
Enable Default Processor 2. Bridge Card
Card Parity and L1 Cache 3. System Board
  4. Memory Card
  
157 1. Default Processor Card
Start of Test Cases 2. Bridge Card
  3. System Board
  
158 1. Default Processor Card
Video Initialization 2. System Board
  3. Bridge Card
 
159 1. Keyboard
Keyboard Initialization 2. System Board
  
15A 1. System Board
Global Initialization 2. Default Processor Card
Try removing the wrap plug
from the serial port.


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.