Error Code/Symptom:
101, 102 1. System Board
(System and microprocessor error)
0103 1. System Board
(System Timer error)
106 1. System Board
(System and microprocessor error)
0110 1. Memory SIMM
(Parity Check 1 XXXX, run Setup) 2. System Board
  
111 1. Memory SIMM
(I/O channel check error) 2. System Board
  
114 1. Run Diagnostics
(Adapter read-only memory error) 2. Failing Adapter
  
0115 1. Memory SIMM
(Parity Check 1 XXXX, run Setup) 2. System Board
  
0120 1. Run Setup
(Previous boot incomplete, 2. Battery/CMOS Chip
default configuration used) 3. System Board
  
0130 1. Battery/CMOS Chip
(Invalid NVRAM media type) 1. System Board
  
151 1. Run Diagnostics
(Real time clock error) 2. System Board
  
161 1. Battery
(Real time clock battery error)
0162 (Models EXX) 1. Battery/CMOS Chip
(Configuration error for 2. System Board
slot XX, run Setup, then, run
the EISA Configuration Utility)
162 (Type 8641 Models MXX) 1. Run Configuration/Setup
(Configuration error)
0163 (Models EXX) 1. Battery/CMOS Chip
(Real-Time Clock error) 2. System Board
  
163 (Type 8641 Models MXX) 1. Run Configuration, set time and date
(Time of day not set)
164 1. Run Configuration
(Memory configuration changed)
165 1. Run Configuration,
(Micro Channel adapter 2. insert Reference diskette
configuration changed)
0171 1. Battery/CMOS Chip
(System battery is dead) 2. System Board
  
0173 1. Run Setup
(System CMOS checksum bad) 2. Battery/CMOS Chip
  3. System Board
  
0174 1. Run Setup
(Invalid ISA Configuration) 2. Look for configuration conflicts.
  3. Battery/CMOS Chip
  
0175 (Models EXX) 1. Run Setup
(EISA Configuration Error, 2. Run EISA Configuration Utility
run the configuration utility) 3. Battery/CMOS Chip
  4. System Board
  
175 (Type 8641 Models MXX) 1. Run Diagnostics
(Hardware error) 2. System Board
  
176 1. Run Configuration/Setup
(Computer cover or cable cover
was removed without a key being
used)
177, 178 1. Run Diagnostics
(Hardware error) 2. System Board
  
184 1. Run Configuration/Setup
(Power-on password corrupted)
185 1. Run Configuration/Setup
(Drive startup sequence
information corrupted)
186 1. Run Configuration/Setup
(System board or security 2. System Board
hardware error)
189 1. Run Configuration,
(An attempt was made to access     enter the administrator password
the computer with an
invalid password)
201 1. Memory SIMM
(Memory test error) 2. System Board
  
0214 1. Memory SIMM
(System RAM failed 2. System Board
at offset XXXX)
0215 1. Memory SIMM
(Failing Bits XXXX) 2. System Board
  
0216 1. Memory SIMM
(Extended RAM failed 2. System Board
at offset XXXX)
0221 1. Memory SIMM
(Shadow RAM failed at offset) 2. System Board
  
0254 1. System Board Cache
(System board Cache error, 2. System Board
Cache disabled)
229 1. Cache memory
(Cache memory test error. 2. System Board
Be sure the cache memory_pd.
is enabled.)
0301 1. Keyboard
(Keyboard or keyboard 2. System Board
controller error)
0302 1. Unlock the keyboard
(Keyboard locked) 2. Keyboard
  3. System Board
  
0303 1. Keyboard
(Keyboard Error, stuck key) 2. System Board
  
604 1. Diskette Drive
(Diskette drive error) 2. Drive Cable
  3. System Board
  
0610 1. Run Setup
(Incorrect drive A type) 2. Diskette Drive
  3. System Board
  4. Diskette Drive Cable
  
0612 1. Run Setup
(Incorrect drive B type) 2. Diskette Drive
  3. System Board
  4. Diskette Drive Cable
  
0632 1. Run Setup
(Diskette drive A error) 2. Diskette Drive
  3. System Board
  4. Diskette Drive Cable
  
0642 1. Run Setup
(Diskette drive B error) 2. Diskette Drive
  3. System Board
  4. Diskette Drive Cable
  
662 1. Run Configuration/Setup
(Diskette drive
configuration error)
762 1. Run Configuration/Setup
(Processor configuration error) 2. Run Diagnostics
  
962 1. Disconnect external cable on
(Parallel port error)     parallel port.
  2. Internal Cable
  3. System Board
  
1162 1. Disconnect ext. cable on serial port.
(System-board serial port 2. Run Configuration
1 or 2 error)
1300 1. Run Setup with known good diskette
(Operating system not found) 2. Fixed Disk Drive
  3. Fixed Disk Adapter
  4. Diskette Drive
  5. System Board
  
1701 1. Run Setup
(Fixed Disk X failed) 2. Fixed Disk Drive
  3. Fixed Disk Adapter
  4. System Board
  
1702 1. Run Setup
(Fixed Disk Drive 2. Fixed Disk Adapter
Controller failed) 3. Fixed Disk Drive
  4. System Board
  
1801 1. Run Reference Diskette
(No room for PCI option ROM) 2. Failing Adapter
  3. System Board
  
1802 1. Run Reference Diskette
(No more I/O space avail. 2. Failing Card
for PCI adapter) 3. System Board
  
1803 1. Run Reference Diskette
(No more memory 2. Failing Card
(above 1MB for PCI adapter) 3. System Board
  
1804 1. Run Reference Diskette
(No more memory 2. Failing Card
(below 1MB for PCI adapter) 3. System Board
  
1805 1. Remove Failing PCI Card
(PCI option ROM 2. System Board
checksum error)
1962 1. Run Configuration/Setup
(No valid boot device found, 2. Run Diagnostics
be sure the drive you want 3. Drive Cable
to start from is 4. Hard Disk Drive
the boot sequence) 5. System Board
  
2401 1. Run Setup and enter correct monitor type
(Monitor type does not match CMOS) 2. Video Display
  3. Video Adapter
  4. System Board
  
2462 1. Display
(Video controller error) 2. System Board
  
000247100 (Type 8641) 1. N/A
L2 processor cache was
disabled, do the following:
Boot the system diagnostics.
Run the processor tests.
When asked if you want to
turn on the processor cache,
reply, "yes," and the
error will be cleared.
I9990301 1. Install operating system
(Fixed boot sector error, 2. to hard disk drive.
no operating system installed)
8601, 8603 1. Pointing Device
(Pointing Device Error) 2. System Board


More INFORMATION / HELP is available at the  IBM-HelpCenter