Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Error Codes (8640 - 300)



Error Codes

Error Code/Symptom    FRU/Action
  
0000 1. Be sure the adapter Device
SCSI Adapter not enabled     Device and Bus Master fiels are enabled
      in the PCI configuration program.
      Refer to the docomentation that was
      shipped with the computer.
  
002X 1. SCSI Adapter
  
008X 1. Check SCSI terminators for proper installation
Check for proper installation 2. SCSI Cable
of SCSI terminators 3. SCSI Terminator
  4. SCSI Device
  5. SCSI Adapter
  
0115 1. System Board
Protected mode cannot
be enabled.
0164 1. Run Setup and ensure the memory sice
POST detected a base     is correct see 'Setup (BIOS Utility)'
memory or expansion memory 2. Run the Expanded Memory Diagnostic tests.
size mismatch.
0601 1. Set Configuration
Diskette configuration error
0610 1. Diskette Drive
Cannot find diskette 2. Diskette Drive Cable
controller for drive A. 3. Diskette Drive Adapter, if installed
  4. System Board
  
0612 1. Diskette Drive
Cannot find diskette 2. Diskette Drive Cable
controller for drive B. 3. Diskette Drive Adapter, if installed
  4. System Board
  
0616 1. Diskette Drive Adapter
Diskette Drive reset failed.
0632 1. Diskette Drive A
Diskette Drive 0 seek failure.
0642 1. Diskette Drive B
Diskette Drive 1 seek failure.
0653 1. Format diskette
Diskette not formatted or defective 2. Diskette
  
0655 1. Diskette Drive
Diskette Drive controller failed 2. Diskette Drive Cable
  3. Diskette Drive Adapter, if installed
  4. System Board
  
107X 1. Check SCSI Terminators for proper installation
Check for proper installation 2. SCSI Cable
of SCSI terminators 3. SCSI Terminator
  4. SCSI Device
  5. SCSI Adapter
  
1701 1. Hard Disk Drive
Hard disk drive failed.
Press F1 to restart the system.
1702 1. Hard Disk Drive Adapter, if installed
Hard disk drive controller error 2. System Board
  
1704 1. Hard Disk Drive Adapter, if installed
Hard disk configuration
error, controller failed.
1715 1. Run Setup and enter the correct hard disk
The Hard Disk drive     drive information.
Configuration information is     (see 'Setup (BIOS Utility)')
not correct.
1726 1. Hard Disk Drive
Hard Disk drive read error
Press F1 to restart the system.
182X 1. SCSI Adapter
  
190X 1. SCSI Cable
Ensure that each SCSI device 2. SCSI Terminator
is properly installed 3. SCSI Device
and powered-on. 4. SCSI Adapter
  
1XXX 1. SCSI Adapter
(not listed above)
221X 1. SCSI Cable
Ensure that each SCSI device 2. SCSI Terminator
is properly installed 3. SCSI Device
and powered-on. 4. SCSI Adapter
  
222X 224X 1. SCSI Adapter
  
2401 1. Correct the Switch setting
The monochrome/color 2. Display Adapter
switch is not set correctly
3XXX 1. Check SCSI terminators for proper installation
Check for proper installation 2. SCSI Cable
of SCSI terminators 3. SCSI Terminator
  4. SCSI Device
  5. SCSI Adapter
  
4XXX 1. SCSI Cable
Ensure that each SCSI 2. SCSI Terminator
is properly installed and 3. SCSI Device
powered-on. 4. SCSI Adapter
  
6XXX 1. SCSI Device
  
GP_COM 1. System Board
The serial port test detected
an error
GP_FDU 1. Diskette Drive
The diskette drive test detected 2. System Board
an error 3. Diskette Drive Cable
  4. Diskette
  
GP_HDU 1. Hard Disk Drive
The hard disk drive test detected 2. Hard Disk Drive Cable
an error 3. Hard Disk Drive Adapter (if installed)
  4. System Board
  
GP_KBD 1. Keyboard
The keyboard test detected 2. System Board
an error
GP_MBD 1. System Board
The system board test detected 2. Processor
an error 3. Real-Time Clock Assembly
  
GP_MEM 1. Memory Module Kit
The memory test detected 2. System Board
an error
GP_PDV 1. Mouse
The mouse test failed. 2. System Board
  
GP_PRT 1. Printer
The printer test detected 2. Printer Cable
an error 3. System Board
  
GP_VID 1. Video Adapter
The video test detected 2. System Board
an error 3. Color Display
  
GRPCDR 1. CD-ROM
The CD-ROM test detected 2. System Board
an error


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.