Error Code/Symptom | FRU/Action |
---|---|
0000 | 1. Be sure the adapter Device |
SCSI Adapter not enabled | Device and Bus Master fiels are enabled |
in the PCI configuration program. | |
Refer to the docomentation that was | |
shipped with the computer. | |
002X | 1. SCSI Adapter |
008X | 1. Check SCSI terminators for proper installation |
Check for proper installation | 2. SCSI Cable |
of SCSI terminators | 3. SCSI Terminator |
4. SCSI Device | |
5. SCSI Adapter | |
0115 | 1. System Board |
Protected mode cannot | |
be enabled. | |
0164 | 1. Run Setup and ensure the memory sice |
POST detected a base | is correct see 'Setup (BIOS Utility)' |
memory or expansion memory | 2. Run the Expanded Memory Diagnostic tests. |
size mismatch. | |
0601 | 1. Set Configuration |
Diskette configuration error | |
0610 | 1. Diskette Drive |
Cannot find diskette | 2. Diskette Drive Cable |
controller for drive A. | 3. Diskette Drive Adapter, if installed |
4. System Board | |
0612 | 1. Diskette Drive |
Cannot find diskette | 2. Diskette Drive Cable |
controller for drive B. | 3. Diskette Drive Adapter, if installed |
4. System Board | |
0616 | 1. Diskette Drive Adapter |
Diskette Drive reset failed. | |
0632 | 1. Diskette Drive A |
Diskette Drive 0 seek failure. | |
0642 | 1. Diskette Drive B |
Diskette Drive 1 seek failure. | |
0653 | 1. Format diskette |
Diskette not formatted or defective | 2. Diskette |
0655 | 1. Diskette Drive |
Diskette Drive controller failed | 2. Diskette Drive Cable |
3. Diskette Drive Adapter, if installed | |
4. System Board | |
107X | 1. Check SCSI Terminators for proper installation |
Check for proper installation | 2. SCSI Cable |
of SCSI terminators | 3. SCSI Terminator |
4. SCSI Device | |
5. SCSI Adapter | |
1701 | 1. Hard Disk Drive |
Hard disk drive failed. | |
Press F1 to restart the system. | |
1702 | 1. Hard Disk Drive Adapter, if installed |
Hard disk drive controller error | 2. System Board |
1704 | 1. Hard Disk Drive Adapter, if installed |
Hard disk configuration | |
error, controller failed. | |
1715 | 1. Run Setup and enter the correct hard disk |
The Hard Disk drive | drive information. |
Configuration information is | (see 'Setup (BIOS Utility)') |
not correct. | |
1726 | 1. Hard Disk Drive |
Hard Disk drive read error | |
Press F1 to restart the system. | |
182X | 1. SCSI Adapter |
190X | 1. SCSI Cable |
Ensure that each SCSI device | 2. SCSI Terminator |
is properly installed | 3. SCSI Device |
and powered-on. | 4. SCSI Adapter |
1XXX | 1. SCSI Adapter |
(not listed above) | |
221X | 1. SCSI Cable |
Ensure that each SCSI device | 2. SCSI Terminator |
is properly installed | 3. SCSI Device |
and powered-on. | 4. SCSI Adapter |
222X 224X | 1. SCSI Adapter |
2401 | 1. Correct the Switch setting |
The monochrome/color | 2. Display Adapter |
switch is not set correctly | |
3XXX | 1. Check SCSI terminators for proper installation |
Check for proper installation | 2. SCSI Cable |
of SCSI terminators | 3. SCSI Terminator |
4. SCSI Device | |
5. SCSI Adapter | |
4XXX | 1. SCSI Cable |
Ensure that each SCSI | 2. SCSI Terminator |
is properly installed and | 3. SCSI Device |
powered-on. | 4. SCSI Adapter |
6XXX | 1. SCSI Device |
GP_COM | 1. System Board |
The serial port test detected | |
an error | |
GP_FDU | 1. Diskette Drive |
The diskette drive test detected | 2. System Board |
an error | 3. Diskette Drive Cable |
4. Diskette | |
GP_HDU | 1. Hard Disk Drive |
The hard disk drive test detected | 2. Hard Disk Drive Cable |
an error | 3. Hard Disk Drive Adapter (if installed) |
4. System Board | |
GP_KBD | 1. Keyboard |
The keyboard test detected | 2. System Board |
an error | |
GP_MBD | 1. System Board |
The system board test detected | 2. Processor |
an error | 3. Real-Time Clock Assembly |
GP_MEM | 1. Memory Module Kit |
The memory test detected | 2. System Board |
an error | |
GP_PDV | 1. Mouse |
The mouse test failed. | 2. System Board |
GP_PRT | 1. Printer |
The printer test detected | 2. Printer Cable |
an error | 3. System Board |
GP_VID | 1. Video Adapter |
The video test detected | 2. System Board |
an error | 3. Color Display |
GRPCDR | 1. CD-ROM |
The CD-ROM test detected | 2. System Board |
an error |
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.