IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
Internal SCSI Drives (Type 8640)
Internal SCSI Drives
The server supports
small computer system interface (SCSI) drives.
You can attach multiple SCSI drives to the preinstalled
SCSI-2 adapter.
If you install additional SCSI devices in a non-disk-array model,
you must set a unique identification (ID)
for each SCSI device that you connect to the SCSI-2 Fast/Wide PCI-Bus
adapter, so that the SCSI-2 adapter can identify the devices and
ensure that different devices do not attempt to transfer data at the same time.
The SCSI IDs in disk-array models with the SCSI-2 Fast/Wide PCI-Bus Adapter are hard-coded
in the backplane of the hot-swap bay and
preset for the CD-ROM drive. Do not attempt to
change the SCSI IDs for internal SCSI devices on disk-array models .
Refer to 'Table 1' before setting SCSI IDs.
Do not set the SCSI IDs for other devices to these values.
NOTE:
Any information about SCSI drives also applies to other
SCSI devices, such as scanners and printers.
See also Termination (Internal SCSI Devices)
More INFORMATION / HELP is available at the IBM-HelpCenter