A configuration file is required to configure the server for
ISA or EISA adapters. You must copy
this configuration file, which has a file-name
extension of .CFG ,
from the device diskette to the EISA Configuration Diskette
before installing the device in the server. The configuration file
reserves the system resources that the adapter needs to function
properly.
Some ISA adapters are supplied with a diskette that contains
the CFG file for the adapter. If ISA adapters are installed that were not
supplied with their own CFG files, you must use the PC Server EISA
Configuration Diskette for the system you are servicing to create a unique
CFG file for each adapter.
NOTE:
The unique .CFG files are slot sensitive . That is, they should
not be used to configure
identical adapters in multiple systems unless you
install the adapters
in the same expansion slots within each system.
To create a unique CFG file for an ISA adapter, do the following:
- Insert the IBM PC Server EISA Configuration Diskette for the system
you are servicing into diskette drive A.
- Start the configuration utility program.
- At the main menu, select Step 2, Add or remove boards.
- At the next menu, select the slot
in which you installed the adapter.
- At the next screen, select OK.
- At the next screen, press F5, then
select Create &period.CFG file&period.
- Press Enter&period.
- At the Create a board CFG file screen,
type in the adapter manufacturer and description (for
example IBM Token Ring), then press Enter&period.
- Refer to the adapter documentation for information about specific
configuration parameters (such as IRQ or DMA channel)
required for the adapter.
Then, follow the instructions on the screen to
enter the appropriate parameters on the menu.
NOTE:
- Normally, ISA adapters do not use
every parameter. Most adapters require only a PORT address.
- The SVGA video adapter in the server requires specific
memory and I/O address assignments to function properly. To
avoid configuration conflicts,
do not assign the following SVGA memory and I/O addresses
to other adapters or options in the server:
- After you type in
all of the appropriate parameters, press F10&period.
- At the next screen, carefully verify that the information is
correct, then press Enter&period.
- At the Add Confirmation window, press Enter again.
- In the next window (add),
press Enter.
The adapter description appears in the selected slot.
- Verify the installation, then press F10.
- At the next menu,
select Save and exit the configuration utility.
NOTE:
PCI devices do not require .CFG files.