Size | Depth 448 mm (17.6 in.)
| Height 160 mm (6.3 in.)
| Width 420 mm (16.5 in.)
Weight | Min. configuration 12.7 kg (28.0 lb.)
| Max. configuration 14.1 kg (31.0 lb.) 1
Environment |
| Air temperature
| - System on 10° to 32°C (50° to 90° F)
| - System off 10° to 43°C (50° to 110° F)
| Humidity
| - System on 8% to 80%
| - System off 8% to 80%
| - Max. altitude 2134m (7000 ft.)
Heat Output |
| Appr. heat output in BTUs per hour.
| - Min. Configuration 120 BTU (35 watts)
| - Max. Configuration 1060 BTU (310 watts) 2
| - Deep sleep 15 BTU (4 watts)
Electrical |
Input | Sine-wave Input (50 to 60 Hz) required.
| Low range input voltage
| - Min. 110 Vac
| - Max. 125 Vac
| High range input voltage
| - Min. 200 Vac
| - Max. 240 Vac
| Input kVA (appr.)
| - Min. configuration as shipped 0.08kVA
| - Max. configuration 0.52 kVA
Airflow |
| Appr. 0.56 cubic meters/minute (20 CFM)
|
Acoustical |
Noise | Average sound pressure levels
Emmission | - At operator position
Values | - 43 dB operating
| - 43 dB idle
| - At bystander position (1 meter)
| - 40 dB operating
| - 40 dB idle
| Declared (upper limit) sound power levels
| - 5.0 bels operating
| - 4.8 bels idle
1 Maximum configuration weight depends on options installed.
Figures above are a system fully populated with options.
2 Maximum power and heat specifications are based on the
200-watt maximum capacity of the system power supply.
For additional information,
see the ISO Supplier's Declaration
available from IBM.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.