Symptom/Error: | FRU/Action. |
---|---|
00010000 | 1. System Board |
0001500X | 1. Perform the Update Firmware |
procedure. (Firmware update | |
was not completed.) | |
2. System Board | |
0001550X | 1. System Board |
00016000 | 1. Battery |
2. System Board | |
00016002 | 1. System Board |
00016003 | CMOS locked during set/reset |
unattended mode. This procedure | |
must be done when computer is | |
first powered on. | |
1. Power off computer | |
2. Power on and load System | |
Management Services Diskette | |
3. Set or reset unattended mode. | |
00016004 | CMOS locked when attemting to |
set or reset Supervisor password. | |
This procedure must be done when | |
computer is first powered on. | |
1. Power off computer | |
2. Power on and load System | |
Management Services Diskette | |
3. Set or reset Supervisor password. | |
00016005 | CMOS locked when attemting to |
set or reset Power on password. | |
This procedure must be done when | |
computer is first powered on. | |
1. Power off computer | |
2. Power on and load System | |
Management Services Diskette | |
3. Set or reset Power on password. | |
00016006 | Supervisory password CRC bad |
1. Battery | |
2. System Board | |
00017001 00017002 | 1. Battery |
2. System Board | |
00017003 | Boot sequence bad, reselect |
Boot Sequence from SMS diskette | |
If problem persists: | |
1. Battery from SMS diskette | |
2. System Board | |
00017006 | Tamper evident or new battery. |
1. The battery was tampered with. | |
or a new battery has been | |
installed, reconfigure ROM with | |
date, time, password and | |
configuration information | |
00017007 00017008 | Computer stopping maximum number of |
password attempts reached. | |
1. Verify password with customer. | |
2. Turn the computer power off and | |
then on. | |
3. Retry password. If the correct password | |
is unknown, the CMOS must be cleared, | |
see 'Removing a Power on Password' | |
00017013 | Power on Password not entered, |
unattended mode can not be set, set | |
password and then set unattended mode. | |
00018000 | Flash ROM image bad |
1. Recover Flash or Reflash | |
system board | |
2. System Board | |
00020000 | 1. See 'Memory' |
000210X0 | 1. See 'Memory' |
2. Memory Module | |
3. System Board | |
000300XX | 1. Keyboard |
NOTE: If XX is 50, you might | |
have pressed a key during testing. | |
Rerun the test. If the problem. | |
persists, replace the keyboard. | |
2. System Board | |
00031100 | 1. Keyboard plugged into wrong port |
(mouse port) | |
00031200 | 1. Keyboard not attached, attach |
keyboard | |
2. Keyboard Cable | |
3. Keyboard | |
4. System Board | |
00061XX0 | 1. System Board |
2. Diskette Drive | |
00062XX0 | 1. Diskette Drive |
2. Diskette Drive Cable | |
3. System Board | |
00063XX0 | 1. Diskette Media |
2. Diskette Drive | |
3. Diskette Drive Cable | |
4. System Board | |
0011XXXX | 1. System Board |
0014XXXX | 1. See 'Printer' |
0017XXXX | 1. EIDE Device |
2. EIDE Cable | |
3. System Board | |
0037XXX0 | 1. see SCSI Symptoms and Error Codes |
008600XX | 1. Mouse |
NOTE: If XX is 50, you might | |
have moved the mouse during testing. | |
Rerun the test. If the problem. | |
persists, replace the mouse. | |
2. System Board | |
01291000 | 1. L2 Cache Memory |
2. System Board | |
0166XXXX | 1. ISA Token Ring Adapter |
0208XXXX to 0209XXXX | 1. see SCSI Symptoms and Error Codes |
0210XXXX to 0219XXXX | 1. see SCSI Symptoms and Error Codes |
02430250 | 1. Video Adapter |
2. Riser Card | |
3. System Board | |
0250100X | 1. System Board |
0265XXXX | 1. ISA Ethernet Adapter |
0267XXXX | 1. System Board |
(PCI Ethernet Controller) | |
0849XXXX | 1. ISA X.25 Adapter |
0942042X | 1. Video Adapter |
2. Riser Card | |
3. System Board | |
50001100 | 1. Firmware does not match System |
Management Service diskette, update | |
system firmware | |
5333000X | 1. Video Adapter |
2. Riser Card | |
3. System Board |