Numeric ERROR Codes Power PC


ERROR - Codes valid only for POWER PC Series products
Symptom/Error:    FRU/Action.
  
00010000 1. System Board
  
0001500X 1. Perform the Update Firmware
      procedure. (Firmware update
      was not completed.)
  2. System Board
  
0001550X 1. System Board
  
00016000 1. Battery
  2. System Board
  
00016002 1. System Board
  
00016003    CMOS locked during set/reset
     unattended mode. This procedure
     must be done when computer is
     first powered on.
  1. Power off computer
  2. Power on and load System
      Management Services Diskette
  3. Set or reset unattended mode.
  
00016004    CMOS locked when attemting to
     set or reset Supervisor password.
     This procedure must be done when
     computer is first powered on.
  1. Power off computer
  2. Power on and load System
      Management Services Diskette
  3. Set or reset Supervisor password.
  
00016005    CMOS locked when attemting to
     set or reset Power on password.
     This procedure must be done when
     computer is first powered on.
  1. Power off computer
  2. Power on and load System
      Management Services Diskette
  3. Set or reset Power on password.
  
00016006    Supervisory password CRC bad
  1. Battery
  2. System Board
  
00017001 00017002 1. Battery
  2. System Board
  
00017003    Boot sequence bad, reselect
     Boot Sequence from SMS diskette
     If problem persists:
  1. Battery from SMS diskette
  2. System Board
  
00017006    Tamper evident or new battery.
  1. The battery was tampered with.
      or a new battery has been
      installed, reconfigure ROM with
      date, time, password and
      configuration information
  
00017007 00017008    Computer stopping maximum number of
     password attempts reached.
  1. Verify password with customer.
  2. Turn the computer power off and
      then on.
  3. Retry password. If the correct password
      is unknown, the CMOS must be cleared,
      see 'Removing a Power on Password'
  
00017013    Power on Password not entered,
     unattended mode can not be set, set
     password and then set unattended mode.
  
00018000    Flash ROM image bad
  1. Recover Flash or Reflash
      system board
  2. System Board
  
00020000 1. See 'Memory'
  
000210X0 1. See 'Memory'
  2. Memory Module
  3. System Board
  
000300XX 1. Keyboard
      NOTE: If XX is 50, you might
      have pressed a key during testing.
      Rerun the test. If the problem.
      persists, replace the keyboard.
  2. System Board
  
00031100 1. Keyboard plugged into wrong port
      (mouse port)
  
00031200 1. Keyboard not attached, attach
      keyboard
  2. Keyboard Cable
  3. Keyboard
  4. System Board
  
00061XX0 1. System Board
  2. Diskette Drive
  
00062XX0 1. Diskette Drive
  2. Diskette Drive Cable
  3. System Board
  
00063XX0 1. Diskette Media
  2. Diskette Drive
  3. Diskette Drive Cable
  4. System Board
  
0011XXXX 1. System Board
  
0014XXXX 1. See 'Printer'
  
0017XXXX 1. EIDE Device
  2. EIDE Cable
  3. System Board
  
0037XXX0 1. see SCSI Symptoms and Error Codes
  
008600XX 1. Mouse
      NOTE: If XX is 50, you might
      have moved the mouse during testing.
      Rerun the test. If the problem.
      persists, replace the mouse.
  2. System Board
  
01291000 1. L2 Cache Memory
  2. System Board
  
0166XXXX 1. ISA Token Ring Adapter
  
0208XXXX to 0209XXXX 1. see SCSI Symptoms and Error Codes
  
0210XXXX to 0219XXXX 1. see SCSI Symptoms and Error Codes
  
02430250 1. Video Adapter
  2. Riser Card
  3. System Board
  
0250100X 1. System Board
  
0265XXXX 1. ISA Ethernet Adapter
  
0267XXXX 1. System Board
      (PCI Ethernet Controller)
  
0849XXXX 1. ISA X.25 Adapter
  
0942042X 1. Video Adapter
  2. Riser Card
  3. System Board
  
50001100 1. Firmware does not match System
      Management Service diskette, update
      system firmware
  
5333000X 1. Video Adapter