FRU P/N
-----------------------------
Scanner FRU 01K1227
Power Adapter 01K1075
Scanner Cable 02K3367
-----------------------------
OPT P/N
-----------------------------
U.S.A 04K0061
EMEA 01K1229
Swiss 01K1230
U.K. 01K1231
Italy 01K1232
Denmark 01K1233
South Afrika 01K1234
Highlights
Installation Information
Industry-standard systems | IBM Personal Computer, Aptiva or IBM-compatible, minimum 486 DX processor, |
---|---|
16 MB RAM, 2MB hard disk drive space to load scanner drivers, 94 MB hard disk | |
drive space to load applications, enhanced parallel port, CD-ROM drive | |
Software/operating systems | Windows 3.1, Windows 95 or Windows NT 4.0 to operate scanner drivers, |
Windows 95 or Windows NT 4.0 to operate Xerox Pagis and Adobe PhotoDeluxe | |
Connectors/cables | Scanner cable (EPP port to scanner) |
Troubleshooting
Try the following for problems specific to the scanner.
Scanner Problem Solving Tips
Symptom | Solution |
---|---|
No scan image on | |
the monitor | Check the power and attachment cables. |
Scanner scans very slowly. | ° Make sure the resolution of the scanner is not set too high. |
A range between 75-200 should work fine. | |
° Set the Parallel Port Mode inside computer's BIOS to EPP | |
(enhanced parallel port). | |
No scanner power | Check for proper attachment of the scanner and the scanner cables. |
Cannot print to printer | ° Check that the printer cable is properly secured to the printer and scanner. |
° Make sure printer is turned on. | |
° Turn off the computer and the printer. | |
Make sure that the scanner is plugged into a constant power source | |
(leave scanner on at all times). | |
Turn the computer on and enter Windows. Once inside Windows turn on | |
the printer and try printing a document. | |
Scanner does not respond | ° Reset the computer (turn it off and on). |
° Enter the Scanner Utility to verify the printer port settings. | |
Poor quality scan image | Check the Windows display setting. The standard display supports 16 colors. |
on the screen | If you need more colors, install a video driver. |
Vertical lines in the | Clean the scanning glass and recheck the image. |
scan image | |
The image is too dark | Check the contrast and brightness settings on the TWAIN driver. |
or too light | Normally both contrast and brightness are set to fifty. |
Scanner does not respond | Reset the computer (turn it off and on). |
The scanned image is | Check the software brightness adjustment. |
solid black | |
Scanner does not emit | Unplug the power cable from the rear of the scanner and open the scanner lid. |
any light. | Looking at the front of the scanner while the lid is open plug the |
power cable back into the scanner. If the light turns on and off quickly, | |
the scanner is working properly. | |
Action Manager does not | ° If you have a printer connected to the scanner, it can cause the Action Manager |
pop-up after pressing the | access button not to work. |
scanner access button. | Disconnect printer cable from scanner and press access button. |
(Windows 3.X) | ° Make sure Action Manager is open. To open Action Manager, enter the Scanner |
Program Group and click on the Action Manager icon. | |
Only distorted output prints. | Purchase a shorter printer cable and try it. Sometimes when information has |
to travel a long distance it becomes distorted. Shortening the printer's cable | |
can decrease the possibility of information becoming damaged. | |
Cannot scan to | ° Look at the Scanner Setup option inside of the application and make sure |
application software | the correct scanner is chosen. |
° Check all connections and make sure they're secure and correct. | |
Unable to find scanner | Check the computer's parallel port to see if it's an EPP by entering |
computer's BIOS. If the parallel port mode is set at ECP or SPP, change to EPP. | |
Save and exit BIOS and run Windows. | |
Enter the Scanner Utility and click the proper address and EPP. Choose Verify Port. | |
If the computer does not support EPP, please purchase an EPP port. | |
The scanner light source | The scanner light source is designed to stay on all the time. |
stays on all the time. | To turn off the scanner light, enter the Scanner Utility and choose Lamp Control. |
The computer's mouse, | ° Upgrade printer port, or controller card to an EPP interface. |
keyboard, or floppy drive | ° Enter BIOS and change the printer port to EPP and its address to 278, or 378. |
do not work. |
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.