The IBM PS/2 ServerGuard Adapter is supported in the following systems:
7546-411/640/641, 8580, 8590, 8595, 9577, 9585, 9590 and 9595
IBM PS/2 ServerGuard Adapter FRU P/N :
FRU P/N 61G3628 ServerGuard Adapter
FRU P/N 33F8354 Backup Battery (3V Lithium)
FRU P/N 71G6222 External Power Control Box (used also with Adv.Syst.Mgmt. Adapter)
ServerGuard Country-specific FRU P/Ns :
| Country | Battery Pack 7.2V NiCad |
External DAA to Modem Cable |
External DAA to PSTN Cable |
PCMCIA Modem |
|---|---|---|---|---|
| Australia | 58G4343 | |||
| Austria | 58G4386 | |||
| Belgium | 82G4776 | 58G4346 | ||
| Brazil | 82G4776 | |||
| Canada | 43G3398 | |||
| Chile | 43G3398 | |||
| China | 58G4332 | |||
| Czechoslovakia | 43G3398 | |||
| Denmark | 58G4333 | |||
| Finland | 58G4334 | |||
| France | 58G4335 | |||
| Germany | 58G4347 | |||
| Greece | 43G3398 | |||
| Hong Kong | 58G4332 | |||
| Hungary | 43G3398 | |||
| Iceland | 58G4336 | |||
| Israel | 58G4338 | |||
| Italy | 58G4339 | |||
| Japan | N.A. | 48G9594 | 66G0901 | |
| Luxembourg | 82G4776 | 43G3398 | ||
| Malaysia | 43G3398 | |||
| Netherlands | 82G4776 | 58G4340 | ||
| Norway | 58G4334 | |||
| New Zealand | 58G4332 | |||
| Poland | 43G3398 | |||
| Portugal | 43G3398 | |||
| Romania | 43G3398 | |||
| Singapore | 43G3398 | |||
| South Africa | 58G3444 | |||
| Spain | 43G3398 | |||
| Sweden | 58G4336 | |||
| Switzerland | 58G4348 | |||
| Taiwan | 82G4776 | 43G3398 | ||
| United Kingdom | 58G4345 | |||
| United States | 43G3398 | |||
| Yugoslavia | 43G3398 | |||
| All other Countries |
61G3629 | 92F0287 | 92F0289 |
About the ServerGuard Adapter
The rechargeable battery pack is designed to keep the ServerGuard Adapter operational in the absence of computer power.
When the computer power is off, the external power control box charges the battery pack. When the computer is on, the computer
charges the battery pack. When the computer power goes down, the IBM ServerGuard Adapter:
Power Control Box LED Indicator Status
| Power status LED |
Cable attached LED |
Indicates | Action |
|---|---|---|---|
| On | The system is turned on and is functioning |
No action is required | |
| Blinking | The adapter is monitoring the system |
No action is required | |
| Off | One of the following: The computer power was turned off for an extended period of time. The battery failed. |
Recharge the battery. Push the power override button and leave the computer power turned on for 24 hours. Replace the battery pack. |
|
| On | Cable attached | No action is required | |
| Off | One of the following: The cable is not attached. The cable is defective. Power Control box is unplugged. |
Attach the cable. Replace the cable. Plug power control box into wall outlet. |
Please see the LEGAL - Trademark notice.