| POST Error | FRU/Action |
|---|---|
| Code/Symptom | |
| 101 | 1. System Board |
| System board interrupt failure. | |
| 102 | 1. System Board |
| System board timer error. | |
| 106 | 1. System Board |
| 110 | 1. Memory Module |
| System board memory parity error. | 2. System Board |
| 111 | 1. Reseat adapters |
| I/O channel parity error. | 2. Any Adapter |
| 3. System Board | |
| 114 | 1. Adapter Memory |
| Adapter ROM error. | 2. System Board |
| 151 | 1. System Board |
| Real-time clock failure. | |
| 161 | 1. Run Setup |
| Bad CMOS battery. | 2. CMOS Backup Battery |
| 3. System Board | |
| 162 | 1. Run Setup and verify Configuration |
| Configuration mismatch. | 2. Had a device been added, removed, changed location? |
| If not, suspect that device. | |
| 3. Power-on external devices first, then power-on computer. | |
| 4. CMOS Backup Battery | |
| 5. System Board | |
| 163 | 1. Time and Date Set? |
| Clock not updating | 2. CMOS Backup Battery |
| or invalid time set. | 3. System Board |
| 164 | 1. Run Setup. Check System Summary menu for memory size change. |
| POST detected a base memory or | 2. Run the Extended Memory Diagnostic tests. |
| extended memory size mismatch error. | |
| 167 | 1. Update the Flash BIOS to the latest level |
| Microprocessor installed that is not | 2. Processor |
| supported by the current POST/BIOS. | |
| 168 | 1. Run Setup. Check to see that Ethernet and Alert on LAN are enabled. |
| Alert on LAN error | 2. System Board |
| 3. Riser Card, if installed. | |
| 175 | 1. Run Configuration |
| 2. System Board | |
| 176 | 1. Covers were removed from the computer. |
| 177 | 1. System Board |
| Corrupted | |
| Administrator Password. | |
| 17X not listed above | 1. C2 Security |
| 183 | 1. Enter the administrator password |
| 184 | 1. Make sure Asset Care and Asset ID are disabled in |
| RFID Antenna Installed | Configuration/Setup. An RFID Antenna should not be installed. |
| 186 | 1. System Board |
| 187 | 1. Clear Administration password |
| 2. System Board | |
| 18X not listed above | 1. C2 Security |
| 190 | 1. System Board |
| Chassis intrusion detector | 2. Riser Card, if installed |
| was cleared. | |
| This is information only, | |
| no action required. | |
| If this code does not clear: | |
| 20X | 1. Run Enhanced Diag. Memory Test |
| Memory data error. | 2. Memory Module |
| 3. System Board | |
| 301 | 1. Keyboard |
| 2. Keyboard Cable | |
| 3. System Board | |
| 303 | 1. Mouse |
| With an 8603 error. | 2. Keyboard |
| 3. Keyboard Cable | |
| 4. System Board | |
| 303 | 1. Keyboard |
| With no 8603 error. | 2. Keyboard Cable |
| 3. System Board | |
| 601 | 1. Diskette Drive A |
| 2. Diskette Drive Cable | |
| 3. Riser Card, if installed | |
| 4. System Board | |
| 602 | 1. Bad Diskette |
| 2. Verify Diskette and retry. | |
| 604 | 1. Run Setup and verify diskette configuration settings |
| 2. Diskette Drive A/B | |
| 3. Diskette Drive Cable | |
| 4. Riser Card if drive cable connected | |
| 5. System Board | |
| 662 | 1. Diskette drive configuration error or wrong diskette drive type, |
| run Setup Configuration. | |
| 762 | 1. Run Setup |
| Math coprocessor | 2. Processor |
| configuration error. | 3. System Board |
| 11XX | 1. Serial Cable |
| Serial port error | 2. Serial device |
| 3. System Board | |
| 1762 | 1. Run Configuration |
| Hard disk drive | |
| configuration error. | |
| 1780 (Disk Drive 0) | 1. See Power Supply |
| 1781 (Disk Drive 1) | 2. Hard Disk Drive |
| 1782 (Disk Drive 2) | 3. Riser Card, if hard disk cable connected |
| 1783 (Disk Drive 3) | 4. System Board |
| 5. Hard Disk Cable | |
| 6. Power Supply | |
| 180X, 188X | 1. Run Setup and verify PCI/ISA configuration settings. |
| PCI configuration | 2. If necessary, set ISA adapters to 'Not available' to allow |
| or resource error. | PCI adapters to properly configure. |
| 3. Remove any suspect ISA adapters. | |
| 4. Rerun diagnostics. | |
| 5. PCI Adapter | |
| 6. PCI Riser Card | |
| 1962 | 1. Run Configuration/Setup, check Boot Sequence. |
| Boot sequence error. | 2. Check cable connections. |
| 3. Run Diagnostics. | |
| 4. Hard Disk Drive | |
| 5. System Board | |
| 2462 | 1. Check cable connections. |
| Video memory configuration | 2. Run Setup and verify video configuration settings. |
| error. | 3. Video Memory Modules |
| 4. Video Adapter (if installed) | |
| 5. System Board | |
| 5962 | 1. Run Configuration |
| An IDE device (other than | 2. CD-ROM Drive |
| hard drive) configuration | 3. CD-ROM Adapter |
| error. | 4. ZIP or other ATAPI device |
| 5. System Board | |
| 8601, 8602 | 1. Pointing Device (Mouse) |
| 2. System Board | |
| 8603, 8604 | 1. System Board |
| 2. Pointing Device (Mouse) | |
| 86XX | 1. Mouse |
| Not listed above | 2. System Board |
| I999030X | Possible hard disk drive problem |
| Hard disk reset failure | |
| Error not listed above | Follow the instructions on the screen |