| __________________________________ |
| IBM ServeRAID BIOS |
| Copyright IBM Corp. 1995,1998 |
| Ver: 3.00.12 08/14/1998 |
| __________________________________ |
| << Press Ctrl+I to access the Mini-Configuration Program. >> |
| |
| Initializing ServeRAID Controller 1 in Slot 1. |
| Power-on self-test can take up to 59 Second(s) - test Passed. |
| Drive configuration can take up to 6 Minute(s) 0 Second(s) - test Passed. |
| ServeRAID Firmware Version:2.82.00 |
| No logical drives found, none are installed. |
| Non-Disk SCSI Devices Found: CD-ROM 0, Tape 0, Removable-media 0, Other 1. |
| |
| BIOS not loaded no devices found - Installation stopped. |
| |
+--------------------------------------------------------------------------------+
If there is a POST Error message, the BIOS screen resembles the sample shown below.
Refer to POST (ISPR) Error Codes and correct the problem.
The characters XXXX indicate the POST (ISPR) error.
+--------------------------------------------------------------------------------+
| |
| __________________________________ |
| IBM ServeRAID BIOS |
| Copyright IBM Corp. 1995,1998 |
| Ver: 3.00.12 08/14/1998 |
| __________________________________ |
| << Press Ctrl+I to access the Mini-Configuration Program. >> |
| Initializing ServeRAID Controller 1 in Slot 1. |
| Power-on self-test can take up to 59 Second(s) - test Failed. |
| Controller is not responding properly - Run Diagnostics. |
| |
| Error Code: XXXX-YY |
| |
| BIOS not loaded no devices found - Installation stopped. |
| |
+--------------------------------------------------------------------------------+
The BIOS screen below shows Configuration Status and/or Error information.
Refer to Drive Configuration Conflict Resolution.
+--------------------------------------------------------------------------------+
| |
| __________________________________ |
| IBM ServeRAID BIOS |
| Copyright IBM Corp. 1995,1998 |
| Ver: 3.00.12 08/14/1998 |
| __________________________________ |
| << Press Ctrl+I to access the Mini-Configuration Program. >> |
| Initializing ServeRAID Controller 1 in Slot 1. |
| Power-on self-test can take up to 59 Second(s) - test Passed. |
| Drive configuration-can take up to 6 Minute(s) 0Second(s) - test Failed. |
| Controller POST and Config Error Codes: ISPR = EF10 BCS = 09 ECS = 20. |
| Following drives not responding(old state: new state: ch SID) |
| (RDY:EMP: 2:0) |
| Your system has a configuration error due to above condition(s). |
| |
| Press: F4 - Retry the command |
| F5 - Update Controller configuration to exclude NON-RESPONDING drives |
| Warning:NON-RESPONDING drives will be set to DDD, DHS, or EMP state|
| F10 - Exit without change |
| |
+--------------------------------------------------------------------------------+
Note: Do not replace a PC ServeRAID Adapter or a system board containing an
imbedded ServeRAID controller for ServeRAID problems unless replacing the adapter/controller is listed in the Symptom-to-FRU Index.
Please see the LEGAL - Trademark notice.