 |                __________________________________                              |
 |                           IBM ServeRAID BIOS                                   |
 |                      Copyright IBM Corp. 1995,1998                             |
 |                       Ver: 3.00.12         08/14/1998                          |
 |                __________________________________                              |
 |     << Press Ctrl+I to access the Mini-Configuration Program. >>               |
 |                                                                                |
 | Initializing ServeRAID Controller 1 in Slot 1.                                 |
 | Power-on self-test can take up to 59 Second(s) - test Passed.                  |
 | Drive configuration can take up to 6 Minute(s) 0 Second(s) - test Passed.      |
 | ServeRAID Firmware Version:2.82.00                                             |
 | No logical drives found, none are installed.                                   |
 | Non-Disk SCSI Devices Found: CD-ROM 0, Tape 0, Removable-media 0, Other 1.     |
 |                                                                                |
 | BIOS not loaded no devices found - Installation stopped.                       |
 |                                                                                |
 +--------------------------------------------------------------------------------+
If there is a POST Error message, the BIOS screen resembles the sample shown below.
Refer to POST (ISPR) Error Codes and correct the problem.
The characters XXXX indicate the POST (ISPR) error.
 +--------------------------------------------------------------------------------+
 |                                                                                |
 |                __________________________________                              |
 |                           IBM ServeRAID BIOS                                   |
 |                      Copyright IBM Corp. 1995,1998                             |
 |                       Ver: 3.00.12         08/14/1998                          |
 |                __________________________________                              |
 |    << Press Ctrl+I to access the Mini-Configuration Program. >>                |
 | Initializing ServeRAID Controller 1 in Slot 1.                                 |
 | Power-on self-test can take up to 59 Second(s) - test Failed.                  |
 | Controller is not responding properly - Run Diagnostics.                       |
 |                                                                                |
 | Error Code: XXXX-YY                                                            |
 |                                                                                |
 | BIOS not loaded no devices found - Installation stopped.                       |
 |                                                                                |
 +--------------------------------------------------------------------------------+
The BIOS screen below shows Configuration Status and/or Error information.
Refer to Drive Configuration Conflict Resolution.
 +--------------------------------------------------------------------------------+
 |                                                                                |
 |                __________________________________                              |
 |                           IBM ServeRAID BIOS                                   |
 |                      Copyright IBM Corp. 1995,1998                             |
 |                       Ver: 3.00.12         08/14/1998                          |
 |                __________________________________                              |
 |    << Press Ctrl+I to access the Mini-Configuration Program. >>                |
 | Initializing ServeRAID Controller 1 in Slot 1.                                 |
 | Power-on self-test can take up to 59 Second(s) - test Passed.                  |
 | Drive configuration-can take up to 6 Minute(s) 0Second(s) - test Failed.       |
 | Controller POST and Config Error Codes: ISPR = EF10 BCS = 09 ECS = 20.         |
 | Following drives not responding(old state: new state: ch SID)                  |
 | (RDY:EMP: 2:0)                                                                 |
 | Your system has a configuration error due to above condition(s).               |
 |                                                                                |
 | Press: F4 - Retry the command                                                  |
 |        F5 - Update Controller configuration to exclude NON-RESPONDING drives   |
 |             Warning:NON-RESPONDING drives will be set to DDD, DHS, or EMP state|
 |        F10 - Exit without change                                               |
 |                                                                                |
 +--------------------------------------------------------------------------------+
Note: Do not replace a PC ServeRAID Adapter or a system board containing an
imbedded ServeRAID controller for ServeRAID problems unless replacing the adapter/controller is listed in the Symptom-to-FRU Index.
Please see the LEGAL  -  Trademark notice.
Feel free - send a 
  for any BUG on this page found - Thank you.