IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
Channel Troubleshooting Procedure
Channel Troubleshooting Procedure
This procedure should be used when there is a problem on the SCSI channel
outboard of the adapter/controller that prevents the adapter/controller from
communicating with the devices attached to that channel.
- For non-hot-swap systems, check termination of identified channel.
- Check for proper cabling configuration in systems that use DASD status cables.
- To determine if a single drive is causing the failure, disconnect one
drive at a time and reboot the system each time.
Continue until you have
disconnected all the drives, or the failure has disappeared.
- Replace SCSI cable.
- Replace SCSI backplane.
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.