| Error Code | FRU/Action |
|---|---|
| All SCSI Errors | 1. External SCSI devices must be powered-on |
| One or more of the following | before you power on the server. |
| might be causing the Problem: | 2. The cables for all external SCSI devices are |
| ° A failing SCSI device | connected correctly. |
| (adapter, drive, controller) | 3. If you have attached an external SCSI device to |
| ° An improper SCSI configuration | the server, make sure the external SCSI termination |
| or SCSI termination jumper | is set to automatic. |
| setting. | 4. The last device in each SCSI chain is terminated |
| ° Duplicate SCSI IDs in the | correctly. |
| same SCSI chain. | 5. The SCSI devices are configured correctly. |
| ° A missing or improperly | |
| installed SCSI terminator. | |
| ° A defective SCSI terminator | |
| ° An improperly installed cable | |
| ° A defective cable |