Beeps | Description |
---|---|
1-2-3 | ° One beep |
° A pause (or break) | |
° Two beeps | |
° A pause (or break) | |
° Three beeps | |
4 | Four continuous beeps |
Beep/Symptom | FRU/Action |
1-1-2 | 1. Optional Processor |
(Processor register | (if installed) |
test failed) | 2. Processor |
1-1-3 | 1. Battery |
(CMOS write/read | 2. System Board |
test failed) | |
1-1-4 | 1. DIMM |
(BIOS ROM checksum | 2. System Board |
failed) | |
1-2-1 | 1. System Board |
(Programmable Interval | |
Timer failed) | |
1-2-2 | 1. System Board |
(DMA initialization | |
failed) | |
1-2-3 | 1. System Board |
(DMA page register | |
write/read failed) | |
1-2-4 | 1. System Board |
RAM refresh verification | |
failed | |
1-3-1 | 1. DIMM |
(1st 64K RAM test failed) | |
1-3-2 | 1. DIMM |
(1st 64K RAM parity test | 2. System Board |
failed) | |
2-1-1 | 1. System Board |
(Secondary DMA register | |
failed) | |
2-1-2 | 1. System Board |
(Primary DMA register | |
failed) | |
2-1-3 | 1. System Board |
(Primary interrupt mask | |
register failed) | |
2-1-4 | 1. System Board |
(Secondary interrupt mask | |
register failed) | |
2-2-1 | 1. System Board |
(Interrupt vector loading | |
failed) | |
2-2-2 | 1. System Board |
(Keyboard controller failed) | |
2-2-3 | 1. Battery |
(CMOS power failure and | 2. System Board |
checksum checks failed) | |
2-2-4 | 1. Battery |
(CMOS configuration info | 2. System Board |
validation failed) | |
2-3-1 | 1. System Board |
(Screen initialization failed) | |
2-3-2 | 1. System Board |
(Screen memory failed) | |
2-3-3 | 1. System Board |
(Screen retrace failed) | |
2-3-4 | 1. System Board |
(Search for video ROM | |
failed) | |
2-4-1 | 1. System Board |
(Video failed, screen | |
believed operable) | |
3-1-1 | 1. System Board |
(Timer tick interrupt failed) | |
3-1-2 | 1. System Board |
(Interval timer channel 2 | |
failed) | |
3-1-3 | 1. DIMM |
(RAM test failed above | 2. System Board |
address 0FFFFH) | |
3-1-4 | 1. Battery |
(Time-Of-Day clock failed) | 2. System Board |
3-2-1 | 1. System Board |
(Serial port failed) | |
3-2-2 | 1. System Board |
(Parallel port failed) | |
3-2-3 | 1. Optional Processor (if installed) |
(Math coprocessor failed) | 2. Processor |
3-2-4 | 1. DIMM |
(Failure comparing CMOS | 2. Battery |
memory size against actual) | |
3-3-1 | 1. DIMM |
(Memory size mismatch | 2. Battery |
occurred) | |
3-3-2 | 1. Disconnect the server power cord from outlet, |
(Critical SMBUS error | wait 30 seconds and retry. |
occurred) | 2. Memory DIMMs |
3-3-3 | 1. Install or reseat the memory modules |
(No memory in system) | 2. DIMMs |
3. System Board | |
Two Short Beeps | 1. Run Diagnostics |
(Information only, the | 2. Run Configuration/Setup |
configuration has changed) | |
Three Short Beeps | 1. DIMM |
2. System Board | |
One Continuous Beep | 1. Processor |
2. Optional Processor (if installed) | |
3. System Board | |
Repeating Short Beeps | 1. Keyboard |
2. System Board | |
One Long and One Short | 1. Video adapter (if present) |
Beep | 2. System Board |
One Long and Two Short | 1. Video adapter (if present) |
Beeps | 2. System Board |
Two Long and Two Short | 1. Video adapter (if present) |
Beeps |
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.