IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
Before You Begin
Before You Begin
- You will need the following items:
- Flat-blade screwdriver
- 8-inch adjustable wrench or pliers
- Tape
- Pencil
Some of the installation procedures require two people.
- Before you begin to install the server in the rack enclosure, review the safety and handling
guidelines specified under 'Safety Information'. These guidelines will help you work
safely while working with the server and options.
- Review the documentation that comes with the rack enclosure for additional safety,
cabling, and operating considerations.
- To ensure cabinet stability, install the servers starting from the bottom of the rack enclosure.
NOTE: If you are installing different server models in the rack enclosure,
install the heaviest models in the lower part of the rack enclosure.
- Ensure that you plan the rack enclosure installation within the guidelines for:
- Heat generation
- Electrical requirements
- Air flow
- Mechanical loading
- Verify that the rack enclosure can meet the following rack model operating parameters:
Size
- Depth: 560 mm (22.05 in.)
- Height: 230 mm (9.06 in.)
- Width: 420 mm (16.54 in.)
Weight
- Typical server as shipped: 39 kg (85.8 lb)
Environment
- Air temperature:
- Server on: 10° to 35° C (50° to 95° F)
Altitude: 0 to 914 m (3000 ft.)
- Server on: 10° to 32° C (50° to 90° F)
Altitude: 914 m (3000 ft.) to 2133 m (7000 ft.)
- Server off: 10° to 43° C (50° to 110° F)
Maximum Altitude: 2133 m (7000 ft.)
- Humidity:
- Server on: 8% to 80%
- Server off: 8% to 80%
- Maximum altitude: 2133 m (7000 ft)
Electrical Input
- Sine-wave input (50 to 60 Hz) is required
- Input voltage:
- Low range:
Minimum: 90 V ac
Maximum: 137 V ac
- High range:
Minimum: 180 V ac
Maximum: 265 V ac
- Input kilovolt-amperes (kVA) approximately:
Minimum configuration as shipped: 0.08 kVA
Maximum configuration: 0.52 kVA
Total Power Available for Drives
- Nominal Operating Current allowed:
- +5 V dc line: 5.3 A
- +12 V dc line: 5.0 A
Heat Output
- Approximate heat output in British Thermal Units (Btu) per hour:
- Minimum configuration:
350 Btu (102 watts)
- Maximum configuration:
860 Btu (251 watts)
Acoustical Noise Emissions Values
- Sound power, idling
- 6.2 bel for open bay system (no hard disk drives installed)
- 6.3 bel for system with one hard disk drive installed)
- Sound power, operating
- 6.2 bel for open bay system (no hard disk drives installed)
- 6.3 bel for system with one hard disk drive installed)
- Sound pressure, idling
- 47 dBa for open bay system (no hard disk drives installed)
- 48 dBa for system with one hard disk drive installed)
- Sound pressure, operating
- 47 dBa for open bay system (no hard disk drives installed)
- 48 dBa for system with one hard disk drive installed)