Environment Minimum Maximum
----------------------------------------------------
Operating 0°C (32°F) 55°C (131°F)
temperature
Storage -20°C (-4°F) 70°C (158°F)
temperature
Relative humidity 10% 90%
(noncondensing)
Storage humidity 5% 95%
(noncondensing)
Type | Specification |
---|---|
Host bus | Conforms to PCI Local Bus Specification, revision 2.1 |
PCI signaling environment | 3.3 V and 5.0 V buses supported |
PCI transfer rate | 264 MB per second maximum burst rate for 33 MHz operation |
(ISP2100 chip) | |
Fibre Channel specifications | Bus type: fibre optic media (QLA2100F) |
Bus transfer rate: 100 MB per second maximum | |
Central processing unit (CPU) | Single chip design that includes a RISC processor, Fibre Channel |
protocol manager, PCI DMA controller, and 1-gigabit transceivers | |
Host data transfer | 64-bit, bus master DMA data transfers to 264 MB per second |
RAM | 128KB of SRAM |
BIOS ROM | 128KB of flash ROM in two 64KB, software selectable banks. |
The flash is field programmable. | |
NVRAM | 256 bytes, field programmable |
Onboard DMA | Three independent DMA channels: two data and one command. |
Integrated 4KB frame buffer FIFO for each data channel | |
Connectors (external) | SC-style connector that supports non-OFC, multimode fibre optic |
cabling using 1 x 9 fibre optic transceiver module. | |
Total cable length cannot exceed 500 meters. | |
Form factor | 17.78 cm x 10.67 cm (7.0 in. x 4.2 in.) |
Operating power | Less than 15 watts |
Please see the LEGAL - Trademark notice.