| DRIVEVER | Use the DRIVEVER command to display the vendor ID, microcode version, and serial |
|---|---|
| number of a SCSI device. The IPSSEND program retrieves this information directly | |
| from the device. | |
| Supported operating systems: Windows NT, OS/2, NetWare, | |
| OpenServer, UnixWare, and DOS | |
| Command: | |
| IPSSEND DRIVEVER Controller Channel SID | |
| Replace: | |
| ° Controller with the ServeRAID controller number (1 to 8) | |
| ° Channel with the channel number for the device (1, 2, or 3) | |
| ° SID with the SCSI ID for the device (0 to 15) | |
| GETCONFIG | Use the GETCONFIG command to display the ServeRAID adapter or controller |
| configuration information. This includes information about the firmware version, | |
| initiator ID and rebuild rate, logical drive status, RAID level, and size, and | |
| physical device type, SCSI ID, and PFA error. | |
| Supported operating systems: Windows NT, OS/2, NetWare, | |
| OpenServer, UnixWare, and DOS | |
| Command: | |
| IPSSEND GETCONFIG Controller Options | |
| Replace: | |
| ° Controller with the ServeRAID controller number (1 to 8) | |
| ° Options with one of the following: | |
| AD for adapter or controller information, LD for logical drive information, | |
| PD for physical device information, AL (default) for all information. | |
| HSREBUILD | Use the HSREBUILD command to set the ServeRAID adapter or controller hot-swap |
| rebuild feature on. Use a question mark (?) to display the current status of the | |
| hot-swap rebuild feature. | |
| Supported operating systems: Windows NT, OS/2, NetWare, | |
| OpenServer, UnixWare, and DOS | |
| Command: | |
| IPSSEND HSREBUILD Controller Options | |
| Replace: | |
| ° Controller with the ServeRAID controller number (1 to 8) | |
| ° Options with ON to enable the hot-swap rebuild feature, or ? | |
| to display the status of the hot-swap rebuild feature. |