Descriptions of the information that appears on the screen are as follows:
| Adapter Number | The active adapter or controller (1 to 8). |
|---|---|
| Number of Logical Drives | The number of defined logical drives (0 to 8). |
| Unattended Mode | Off - The user chooses the recovery method when there is a |
| ServeRAID startup error. | |
| On - The adapter or controller chooses the recovery method when | |
| there is a ServeRAID startup error. | |
| Code Block Version | The current version number of the firmware loaded on the adapter or controller. |
| Boot Block Version | The current version number of the bootable microcode loaded on the |
| adapter or controller. | |
| Concurrent Commands | The maximum number of concurrent commands supported. |
| Maximum Devices Supported | The maximum number of devices supported. |
| Flash Program Count | The current number of times the flash EEPROM has been written. |
| Defunct Disk Count | The current number of defunct hard disk drives. |
| Rebuild Rate | The current setting (Low, Medium, or High) of the rebuild rate. |
| Hot-Swap Rebuild | The current state (Enabled or Disabled) of the hot-swap rebuild feature. |
| Offline Logical Drive Count | The current number of offline logical drives. |
| Configuration Update Count | The number of times that the ServeRAID configuration has been updated. |
| NVRAM Battery Backup Device | The current state of the battery-backup cache (installed, |
| not installed, or defective). |