Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

NetWare Run-Time Messages



NetWare Run-Time Messages

It is possible that an Unrecoverable, or recoverable, error might occur during normal operation of the adapter. The following table describes the run-time errors that might be displayed.

Recoverable Errors and Warnings

Error Message    FRU/Action
  
58: The board does not 1. If the driver is not able to recover
respond     from any of these errors after several
110: Unable to download the     minutes, replace the 10Base-T or 10Base2 adapter
the firmware
111: Invalid Pipe Command
112: The board watchdog
failed
113: Adapter resetting ...
please wait
These messages indicate that
errors have occured during
the recovery process. The driver
will attempt to recover control
of the adapter at priodic intervals
229: The adapter alert condition 1. N/A
has been corrected
This message indicates the
successful recovery from one
of the above run-time error
conditions.
388: Ethernet Media Port 1 Tx 1. Check cables, adapter cables or concentrator
Carrier Sense Errors,
check the cable
389: Ethernet Media Port 2 Tx
Carrier Sense Errors,
check the cable
390: Ethernet Media Port 3 Tx
Carrier Sense Errors,
check the cable
391: Ethernet Media Port 4 Tx
Carrier Sense Errors,
check the cable
395: Ethernet Media Port 1 Tx 1. N/A
Carrier Sense Errors,
corrected
396: Ethernet Media Port 2 Tx
Carrier Sense Errors,
corrected
397: Ethernet Media Port 3 Tx
Carrier Sense Errors,
corrected
398: Ethernet Media Port 4 Tx
Carrier Sense Errors,
corrected
Problem is solved


Unrecoverable Errors

If you receive an error that is not described in the preciding error-message lists, you might have an Unrecoverable (fatal) error. The error message indicates that the adapter has experienced an Unrecoverable run-time error.

To make the adapter functional, unload the drivers, then reload them. If unloading and reloading the drivers does not make the adapter functional, restart the computer and try again.

If the above procedures do not correct the problem, replace the 10Base-T or 10Base2 adapter.


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.