NetWare Load-Time Error Messages



NetWare Load-Time Error Messages

Error Message    FRU/Action
  
050: The board cannot be found 1. Verify that the adapter is properly installed
The driver assumes that the adapter 2. 10Base-t or 10Base2 Adapter
has not been installed.
058: The board does not respond 1. Restart the computer or run the system
070: The board has failed     configuration program to check for
The driver cannot communicate     possible system conflicts
with the adapter. 2. 10Base-t or 10Base2 Adapter
  
073: Unable to allocate memory 1. Unload the driver and unnecessary NLMs
The driver was not able to     and try again
allocate sufficient memory to 2. Reload the server and try again
perform its function 3. Install additional memory into the server
  
110: Unable to download the firmware 1. Restart the computer or run the system
The driver is not able to     configuration program to check for possible
communicate with the adapter     system conflicts.
  2. 10Base-T or 10Base2 adapter
  
203: Board diags failed to complete 1. Restart the computer or run the system
The driver is not able to communicate     configuration program to check for
with the adapter.     possible system conflicts
  2. 10Base-T or 10Base2 adapter.
  
301: POST Flash Main 1. 10Base-T or 10Base2 adapter
Sector Checksum Failure
302: POST was not
performed - board
303: POST Test
Sequencer Internal Failure
304: POST Flash Boot
Sector Checksum
305: POST DRAM Size 1. Verif proper seating of the DRAM SIMM
Detection Failure     on the adapter.
The power unit is down 2. 10Base-T or 10Base2 adapter
  
306: POST DRAM Byte 1. Verify proper seating of the DRAM SIMM
(8-bit) Wide Failure     on the adapter
307: POST DRAM Short 2. 10Base-T or 10Base2 adapter
(16-bit) Wide Failure
308: POST DRAM Word
(32-bit) Wide Failure
309: POST DRAM Long
(64-bit) Wide Failure
310: POST DRAM Trip
(96-bit) Wide Failure
311: POST DRAM Quad
(128-bit) Wide Failure
312: POST DRAM Quad
Addressability Failure
The power unit is down
313: SRAM Size Detection 1. 10Base-T or 10Base2 adapter
Failure
314: SRAM Byte (8-bit)
Wide Failure
315: SRAM Short (16-bit)
Wide Failure
316: SRAM Word (32-bit)
Wide Failure
317: SRAM Long (64-bit)
Wide Failure
318: SRAM Trip (96-bit)
Wide Failure
319: SRAM Quad (128-bit)
Wide Failure
320: SRAM Addressability
Failure
321: Timer Failure
322: Port 1 Internal
Loopback Failure
323: Port 2 Internal
Loopback Failure
324: Port 3 Internal
Loopback Failure
325: Port 4 Internal
Loopback Failure
326: Ethernet Port 1 1. Verify correct cabling of the port
Ext. Loopback Failure 2. 10Base-T or 10Base2 adapter
327: Ethernet Port 2
Ext. Loopback Failure
328: Ethernet Port 3
Ext. Loopback Failure
329: Ethernet Port 4
Ext. Loopback Failure
330: Port 1 Device 1. 10Base-T or 10Base2 adapter
Verification Failure
331: Port 2 Device
Verification Failure
332: Port 3 Device
Verification Failure
333: Port 4 Device
Verification Failure