| Error Symptom | FRU/Action |
|---|---|
| CD is not working properly. | 1. Clean the CD |
| 2. Clean the optical-head lens. | |
| 3. CD-ROM Drive | |
| CD-ROM drive tray is not | 1. Insert the end of a paper clip into the |
| working. | manual tray-release opening. |
| (The server must be | 2. CD-ROM Drive |
| powered-on.) If the server | |
| is on and the tray does not | |
| eject, | |
| CD-ROM drive is not | 1. Run Configuration/Setup, enabled primary IDE channel. |
| recognized. | 2. Check cables and jumpers. |
| 3. Check for correct device driver. | |
| Power switch does not work | 1. Verify that the power-on control jumper |
| and reset button does work. | on J32's extension cable is on pins 1 and 2. |
| 2. Power Switch Assembly | |
| 3. System Board | |
| Diskette drive in-use light | If there is a diskette in the drive, verify that: |
| stays on, or the system | 1. The diskette drive is enabled in the |
| bypasses the diskette drive, | configuration programs. |
| or the diskette drive does | 2. The diskette is good and not damaged. |
| not work. | (Try another diskette if you have one.) |
| 3. The diskette is inserted correctly in the drive. | |
| 4. The diskette contains the necessary files to | |
| start the server. | |
| 5. The software program is OK. | |
| 6. Run Diskette Drive Diagnostics. | |
| 7. Cable | |
| 8. Diskette Drive | |
| 9. System Board | |
| If the diskette drive in-use light stays on, or | |
| the system continues to bypass the diskette drive, | |
| replace the diskette drive. | |
| Monitor problems (general) | 1. Monitor |
| Some IBM monitors have | 2. Run Video Diagnostics. If |
| their own self-tests. If you | diagnostics pass, the problem |
| suspect a problem with the | may be a video driver |
| monitor, refer to the | 3. Display Adapter/System Board |
| information that comes with | |
| the monitor for adjusting | |
| and testing instructions. |