000 | The test passed. |
---|---|
195 | The Esc key was pressed to abort the test |
197 | This is a warning error and may not indicate |
a hardware failure. |
For all other error codes, replace/follow the FRU/Action indication.
Error Code/Symptom | FRU/Action |
---|---|
001-XXX-000 | 1. System Board |
(Failed core tests) | |
001-XXX-001 | 1. Processor Board |
(Failed core tests) | |
001-250-000 | 1. System Board |
(Failed system board ECC) | |
001-250-001 | 1. Processor Board |
(Failed processor board ECC) | 2. System Board |
005-XXX-000, 005-XXX-001 | 1. System Board |
(Failed Video test) | 2. Processor Board |
011-XXX-000 | 1. System Board |
(Failed COM1 Serial Port test) | |
Note: The external loopback test | |
of Serial Port A will fail | |
if run remotely. | |
011-XXX-001 | 1. System Board |
(Failed COM2 Serial Port test) | |
014-XXX-000, 014-XXX-001 | 1. System Board |
(Failed Parallel Port test) | |
015-XXX-001 | 1. System Board |
(Failed USB test) | |
020-XXX-000 | 1. Processor Board |
(Failed PCI Interface test) | 2. System Board |
020-XXX-001 | 1. Latch on PCI Hot plug Slot #1 |
(Failed Hot Swap PCI Latch | 2. System Board |
test) | |
020-XXX-002 | 1. Latch on PCI Hot plug Slot #2 |
(Failed Hot Swap PCI Latch | 2. System Board |
test) | |
020-XXX-003 | 1. Latch on PCI Hot plug Slot #3 |
(Failed Hot Swap PCI Latch | 2. System Board |
test) | |
020-XXX-004 | 1. Latch on PCI Hot plug Slot #4 |
(Failed Hot Swap PCI Latch | 2. System Board |
test) | |
030-XXX-000, 030-XXX-001 | 1. System Board |
(Failed Internal SCSI | |
interface test) | |
035-XXX-000 | 1. Verify RAID adapter |
(Failed System Board RAID test. | disable jumper block |
Check System Error Log before | is not installed. |
replacing a FRU.) | 2. System Board |
3. SCSI Backplane | |
4. Cable | |
035-XXX-001 | 1. Fixed Disk 1 |
(Failed RAID test for Fixed | |
Disk in bay 1 SCSI ID 0 | |
035-XXX-002 | 1. Fixed Disk 2 |
(Failed RAID test for Fixed | |
Disk in bay 2 SCSI ID 1 | |
035-XXX-003 | 1. Fixed Disk 3 |
(Failed RAID test for Fixed | |
Disk in bay 3, SCSI ID 2) | |
035-XXX-004 | 1. Fixed Disk 4 |
(Failed RAID test for Fixed | |
Disk in bay 4, SCSI ID 3) | |
035-XXX-005 | 1. Fixed Disk 5 |
(Failed RAID test for Fixed | |
Disk in bay 5, SCSI ID 4) | |
035-XXX-006 | 1. Fixed Disk 6 |
(Failed RAID test for Fixed | |
Disk in bay 6, SCSI ID 5) | |
035-XXX-007 | 1. System Board |
(Failed System Board RAID | |
test) | |
035-XXX-100 | 1. Adapter |
(Failed RAID test on PCI | 2. SCSI Backplane |
slot 1. Check System Error | 3. Cable |
Log before replacing a FRU.) | |
035-XXX-1NN | 1. Fixed Disk with SCSI |
(Check System Error Log | ID NN on RAID |
before replacing a FRU. | adapter in PCI slot 1 |
NN = SCSI ID of failing | |
fixed disk.) | |
035-XXX-200 | 1. Adapter |
(Failed RAID test on PCI | 2. SCSI Backplane |
slot 2. Check System Error | 3. Cable |
Log before replacing a FRU.) | |
035-XXX-2NN | 1. Fixed Disk with SCSI |
(Check System Error Log | ID NN on RAID |
before replacing a FRU. | adapter in PCI slot 2 |
NN = SCSI ID of failing | |
fixed disk.) | |
035-XXX-300 | 1. Adapter |
(Failed RAID test on PCI | 2. SCSI Backplane |
slot 3. Check System Error | 3. Cable |
Log before replacing a FRU.) | |
035-XXX-3NN | 1. Fixed Disk with SCSI |
(Check System Error Log | ID NN on RAID |
before replacing a FRU. | adapter in PCI slot 3 |
NN = SCSI ID of failing | |
fixed disk.) | |
035-XXX-400 | 1. Adapter |
(Failed RAID test on PCI | 2. SCSI Backplane |
slot 4. Check System Error | 3. Cable |
Log before replacing a FRU.) | |
035-XXX-4NN | 1. Fixed Disk with SCSI |
(Check System Error Log | ID NN on RAID |
before replacing a FRU. | adapter in PCI slot 4 |
NN = SCSI ID of failing | |
fixed disk.) | |
035-XXX-500 | 1. Adapter |
(Failed RAID test on PCI | 2. SCSI Backplane |
slot 5. Check System Error | 3. Cable |
Log before replacing a FRU.) | |
035-XXX-5NN | 1. Fixed Disk with SCSI |
(Check System Error Log | ID NN on RAID |
before replacing a FRU. | adapter in PCI slot 5 |
NN = SCSI ID of failing | |
fixed disk.) | |
035-253-N00 | 1. ServeRAID Adapter is not |
(RAID initialization error for | configured correctly. |
adapter in PCI slot number N.) | Refer to theIBM ServeRAID HMM |
for more information. | |
075-XXX-000, 075-XXX-001 | 1. Power Supply |
(Failed Power Supply test) | |
089-XXX-001 | 1. VRM 1 or VRM 2 |
(Failed Microprocessor test) | 2. Microprocessor CPU 1 |
089-XXX-002 | 1. VRM 3 or VRM 2 |
(Failed Microprocessor test) | 2. Microprocessor CPU 2 |
089-XXX-003 | 1. VRM 4 or VRM 5 |
(Failed Microprocessor test) | 2. Microprocessor CPU 3 |
089-XXX-004 | 1. VRM 6 or VRM 5 |
(Failed Microprocessor test) | 2. Microprocessor CPU 4 |
165-XXX-000 | 1. System Board |
(Failed System Board test) | 2. Hot-Swap Drive Backplane |
165-XXX-001 | 1. System Board |
(Failed System Board test) | 2. Processor Board |
3. Power Backplane | |
4. Hot-Swap Drive Backplane | |
175-XXX-001 | 1. Fan 1 |
(Failed Fan 1 test) | |
175-XXX-002 | 1. Fan 2 |
(Failed Fan 2 test) | |
175-XXX-003 | 1. Fan 3 |
(Failed Fan 3 test) | |
175-XXX-004 | 1. Check system cooling |
(Processor Board | |
Temperature sensor out of | |
range) | |
180-XXX-000 | |
(Diagnostics LED failure) | 1. Run Diagnostic LED test for the failing LED |
180-XXX-001 | 1. Information LED Panel |
(Failed Information Panel | 2. Power Switch Assembly |
LED test) | |
180-XXX-002 | 1. Diagnostics LED Panel |
(Failed Diagnostics LED | 2. Power Switch Assembly |
Panel test) | |
180-XXX-003 | 1. Run hot-swap PCI latch test in |
(Failed System Board LED | Other Devices under Extended Tests |
test) | 2. System Board |
180-XXX-004 | 1. Processor Board |
(Failed Processor Board | 2. System Board |
LED test) | |
180-XXX-005 | 1. Hot Swap SCSI Backplane |
(Failed Hot Swap SCSI | 2. SCSI Backplane Cable |
Backplane LED test) | 3. System Board |
201-XXX-001 | 1. DIMM Location J15 for 5000-8659, J1 for 5500-866x |
(Failed Memory test, | |
for 5000-8659 see Memory Settings | |
for 5500-866x see Memory Settings) | |
201-XXX-002 | 1. DIMM Location J16 for 5000-8659, J2 for 5500-866x |
(Failed Memory test, | |
for 5000-8659 see Memory Settings | |
for 5500-866x see Memory Settings) | |
201-XXX-003 | 1. DIMM Location J17 for 5000-8659, J3 for 5500-866x |
(Failed Memory test, | |
for 5000-8659 see Memory Settings | |
for 5500-866x see Memory Settings) | |
201-XXX-004 | 1. DIMM Location J22 for 5000-8659, J4 for 5500-866x |
(Failed Memory test, | |
for 5000-8659 see Memory Settings | |
for 5500-866x see Memory Settings) | |
201-XXX-005 | 1. DIMM Location J5 |
(Failed Memory test, | |
See Memory Settings) | |
201-XXX-006 | 1. DIMM Location J6 |
(Failed Memory test, | |
See Memory Settings) | |
201-XXX-007 | 1. DIMM Location J7 |
(Failed Memory test, | |
See Memory Settings) | |
201-XXX-008 | 1. DIMM Location J8 |
(Failed Memory test, | |
See Memory Settings) | |
201-XXX-999 | 1. See error text for failing DIMMs |
(Multiple DIMM failure, | |
see error text) | |
202-XXX-001 | 1. VRM 2 or VRM 1 |
(Failed System Cache test) | 2. Microprocessor CPU 1 |
202-XXX-002 | 1. VRM 2 or VRM 3 |
(Failed System Cache test) | 2. Microprocessor CPU 2 |
202-XXX-003 | 1. VRM 5 or VRM 4 |
(Failed System Cache test) | 2. Microprocessor CPU 3 |
202-XXX-004 | 1. VRM 5 or VRM 6 |
(Failed System Cache test) | 2. Microprocessor CPU 4 |
206-XXX-000, 206-XXX-001 | 1. Diskette Drive cable |
(Failed Diskette Drive test) | 2. Diskette Drive |
3. System Board | |
215-XXX-000 | 1. CD-ROM Drive Cable |
(Failed IDE CD-ROM test) | 2. CD-ROM Drive |
3. System Board | |
215-XXX-001 | 1. System Board |
(Failed IDE test) | |
217-XXX-000 | 1. Fixed Disk 1 (8659, 8661, 8662) |
(Failed BIOS Fixed Disk | |
test) | |
Note If RAID is | |
configured, the fixed disk | |
number refers to the RAID | |
logical drive. | |
217-XXX-001 | 1. Fixed Disk 2 (8659, 8661, 8662) 1 (8660) |
(Failed BIOS Fixed Disk | |
test) | |
Note If RAID is | |
configured, the fixed disk | |
number refers to the RAID | |
logical drive. | |
217-XXX-002 | 1. Fixed Disk 3 (8659, 8661, 8662) 2 (8660) |
(Failed BIOS Fixed Disk | |
test) | |
Note If RAID is | |
configured, the fixed disk | |
number refers to the RAID | |
logical drive. | |
217-XXX-003 | 1. Fixed Disk 4 (8659, 8661, 8662) 3 (8660) |
(Failed BIOS Fixed Disk | |
test) | |
Note If RAID is | |
configured, the fixed disk | |
number refers to the RAID | |
logical drive. | |
217-XXX-004 | 1. Fixed Disk 5 (8659, 8661, 8662) 4 (8660) |
(Failed BIOS Fixed Disk | |
test) | |
Note If RAID is | |
configured, the fixed disk | |
number refers to the RAID | |
logical drive. | |
217-XXX-005 | 1. Fixed Disk 6 (8659, 8661, 8662) 5 (8660) |
(Failed BIOS Fixed Disk | |
test) | |
Note If RAID is | |
configured, the fixed disk | |
number refers to the RAID | |
logical drive. | |
217-XXX-006 | 1. Fixed Disk 6 (8660) |
(Failed BIOS Fixed Disk | |
test) | |
Note If RAID is | |
configured, the fixed disk | |
number refers to the RAID | |
logical drive. | |
264-XXX-0NN | 1. Tape Cartridge, if user executed the |
(NN = SCSI ID of failing | Read/Write Tape Drive test (xxx = 256) |
Tape Drive) | 2. SCSI or Power Cable connected to tape drive |
with SCSI ID NN. | |
3. Tape Drive with SCSI ID NN. | |
4. System board or SCSI Controller. (Run SCSI | |
Controller Diagnostic to determine if the SCSI | |
bus is functioning properly.) | |
264-XXX-999 | 1. See error messages/text in the |
(Errors on multiple tape | error log for detailed information on each |
drives, see error text for | individual tape drive error. |
more info) | |
301-XXX-000, 301-XXX-001 | 1. Keyboard |
(Failed Keyboard test) | |
405-XXX-000 | 1. Verify that the Ethernet Disable Jumper is |
(Failed Ethernet test on | not installed. |
controller on the system | 2. System Board |
board) | |
405-XXX-00N | 1. Adapter in PCI slot N |
(Failed Ethernet test on | 2. System Board |
adapter in PCI slot N) | |
415-XXX-000 | 1. Cable |
(Failed Modem test) | 2. Modem |
3. System Board |
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.