Enabled Alerts Dialout Group



Enabled Alerts Dialout Group

Use the selections available in the Enabled Alerts Dialout group to specify which Advanced Systems Management Adapter events will result in all currently configured Dialout Entries being contacted by the Advanced Systems Management Adapter. Any selected items will, if detected by the Advanced Systems Management Adapter, result in an alert describing the event being forwarded, using the method selected in the Type field, to the recipient specified by the Dialout Entry. The Enable Alerts Dialout group is divided into Critical, Non-Critical, and System groups.


The Critical Enabled Alerts Dialout group contains the following items.
Item / Numeric Code    Description (if checked)
  
Temperature 00    The Advanced Systems Management Adapter will dial
     out if any monitored temperatures exceed their
     threshold values and will then automatically initiate a
     system shutdown.
Voltage 01    The Advanced Systems Management Adapter will dial
     out if the voltages of any monitored power sources fall
     outside their specified operational ranges.
Tamper 02    The system management subsystem will add an entry
     in the Event Log if six consecutive remote login attempts fail.
Multiple fan 03    The Advanced Systems Management Adapter will dial
failure    out if two (or more) of the system's cooling fans fail
     and will automatically initiate a system shutdown.
   Note: This function is available only on some IBM
     systems. For a list of systems that support
     this feature, see 'Supported Advanced Functions'.
Power failure 04    The Advanced Systems Management Adapter will dial
     out if the system's power supply fails.
   Note: This function is available only on some IBM
     systems. For a list of systems that support
     this feature, see 'Supported Advanced Functions'.
Hard disk drive 05    The Advanced Systems Management Adapter will dial
     out if one or more of the hard disk drives in the
     system fail.
   Note: This function is available only on some IBM
     systems. For a list of systems that support
     this feature, see 'Supported Advanced Functions'.
Voltage regulator 06    The system management subsystem will dial out and then
module failure    automatically initiate a subsystem shutdown if the voltage
     regulator module (VRM) fails.
   Note: This function is available only on some IBM systems.


The Non-critical Enabled Alerts Dialout group contains the following items.
Item / Numeric Code    Description (if checked)
  
Temperature 12    The Advanced Systems Management Adapter will dial
     out if any monitored temperatures exceed their
     threshold values. However, unlike the Critical
     Temperature event, this Alerts Dialout will not initiate a
     system shutdown automatically.
   Note: This function is available only on some IBM
     systems. For a list of systems that support
     this feature, see 'Supported Advanced Functions'.
Single fan 11    The Advanced Systems Management Adapter will dial
failure    out if one of the system's cooling fans fail.
   Note: This function is available only on some IBM
     systems. For a list of systems that support
     this feature, see 'Supported Advanced Functions'.
Voltage 13    The Advanced Systems Management Adapter will dial
     out if any of the monitored voltages exceed their
     threshold values.


The System Enabled Alerts Dialout group contains the following items.
Item / Numeric Code    Description (if checked)
  
POST timeout 20    The Advanced Systems Management Adapter will dial
     out if the POST timeout value (specified in the
     Service Processor Configuration Settings window) is
     exceeded.
Loader timeout 26    The Advanced Systems Management Adapter will dial
     out if the Loader timeout value (specified in the
     Service Processor Configuration Settings window) is
     exceeded.
O/S timeout 21    The Advanced Systems Management Adapter will dial
     out if the O/S timeout value (specified in the Service
     Processor Configuration Settings window) is exceeded.
Power off 23    The Advanced Systems Management Adapter will dial
     out if the system is powered off.
Power on 24    The Advanced Systems Management Adapter will dial
     out if the system is powered on.
Application 22    The Advanced Systems Management Adapter will dial
     out if it receives a Netfinity alert (Netfinity can forward
     alerts directly to the Advanced Systems Management
     Adapter using the Alert Manager Forward Alert to
     Service Processor action)
PFA 27    The Advanced Systems Management Adapter will dial
     out if it receives a Predictive Failure Analysis (PFA) alert
     from the system.