IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
POST Timeout
POST Timeout
Note: This function requires a specially architected POST routine and is
available only on some IBM systems.
The POST Timeout field shows the number of seconds that the
Advanced Systems Management Adapter will wait for the system's
power-on self test (POST) to complete before generating a POST
Timeout event. If POST takes longer than the configured amount of
time to complete and the POST timeout check box (found in the
Enabled Alerts Dialout group on the Automatic Dialout Settings
window) is checked, the Advanced Systems Management Adapter
will automatically restart the system one time and will attempt to
forward an alert to all enabled Dialout Entries.
Once the system is restarted POST timeout is automatically disabled.
To set the POST timeout value, use the spin buttons beside the
POST Timeout field to set the number of seconds that the Advanced
Systems Management Adapter will wait for POST to complete.
Then, click on Apply to save this value.
For more information on the Automatic Dialout Settings window, see
'Automatic Dialout Settings'.
Note: This function requires a specially architected POST routine
and is available only on some IBM systems.
For a list of systems that support this feature, see 'Supported Advanced Functions'.
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.