Server ServeRAID ServeRAID II ServeRAID 3L ServeRAID 3H
--------------------------------------------------------------------------------------
PC Server 300 Not Supported Not Supported Not Supported Not Supported
PC Server 310 Not Supported Not Supported Not Supported Not Supported
PC Server 315 Not Supported Yes Not Supported Not Supported
PC Server 320 Yes Yes Not Supported Not Supported
PC Server 325 Yes Yes 1 Yes 1 Yes 1
PC Server 330 Yes Yes Yes Yes
PC Server 500 Not Supported Not Supported Not Supported Not Supported
PC Server 520 Yes Yes Not Supported Not Supported
PC Server 704 Yes Yes Not Supported Not Supported
PC Server 720 Yes Yes 2 Not Supported Not Supported
--------------------------------------------------------------------------------------
Netfinity 3000 Not Supported Not Supported Yes Yes
Netfinity 3500 Not Supported Yes 3 Yes Yes
Netfinity 5000 Not Supported Yes Yes Yes
Netfinity 5500 Not Supported Yes Yes Yes
Netfinity 5500-M10 Not Supported Yes Yes Yes
Netfinity 7000 Not Supported Yes Yes Yes
Netfinity 7000-M10 Not Supported Yes Yes Yes
--------------------------------------------------------------------------------------
Note:
1. Only the following models of the Server 325 are supported: 8639-EJ0, ES0, ESV, RSO, PT0, PTW, PB0, RB0.
2. OS/2 is not supported.
3. SCO UnixWare 2.1.2 is not supported.
The ServeRAID-3H is a 64-bit PCI adapter offering three Ultra2 SCSI channels with one internal SCSI
connector and two or three external SCSI connectors.
The ServeRAID-3L is its entry level sibling: it is a 32-bit PCI adapter with one Ultra2 SCSI channel.
Both the 3H and 3L adapters support both single ended (SE) and low-voltage differential (LVD) SCSI
disk drives.
The Ultra2 SCSI interface supports RAID-0, RAID-1, RAID-1 Enhanced, and RAID-5 logical
drives and supports SCSI, SCSI-2, Ultra SCSI and Ultra2 SCSI drives.
The ServeRAID-3H is a replacement for the IBM ServeRAID II Ultra SCSI Adapter, (OPT P/N 76H3584), and
the IBM ServeRAID SCSI Adapter (OPT P/N 70G8489).
Features ServeRAID ServeRAID II ServeRAID-3L ServeRAID-3H
-----------------------------------------------------------------------------------------------------
Internal Connectors 3 3 1 1
External Connector (standard/max) 1 / 1 2 / 3 1 / 1 2 / 3
External Connector Type 68 pin VHDCI VHDCI VHDCI
Cache 4 MB 4 MB 4 MB 32 MB
Battery-Backup Cache Option No Yes No Yes
Autosync No Yes Yes Yes
PCI Bus -------------- 33 MHz 32-bit PCI ------------- 33 MHz 64-bit
or 32-bit PCI
LVDS Support No No Yes Yes
I 2 O Enabled No No Yes Yes
Hot-Swap PCI Support No Yes Yes Yes
Fault Tolerant Adapter Pair No Yes Yes Yes
Automatic Hot Swap Rebuild Yes Yes Yes Yes
Data Scrubbing No Yes Yes Yes
Logical Drive Migration Yes Yes Yes Yes
Command Line Utilities Yes Yes Yes Yes
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.