Note:
F=Fast F/W=Fast/Wide HS=Hot-Swap MC=Micro Channel Par=Parity SIMM
x = Upgradeable to 133MHz processor
y = ECC-on-SIMM memory is available as an Option.
z = Upgradeable to 200MHz processor
PC Server 720 - 8642
Each PC Server 720 model can support up to six 100MHz, 133MHz or 166MHz processor cards in any combination.
| Mod | Std. Capacity | Seek Time ms | RPM | Max. Cap. GB | Hot Swap max. Cap. | Std. HD I/F | SCSI-2 Ctrl | Pent Proc MHz | SMP std max | L2 Cache Std max | Mem std. max. (MB unless noted) | Exp. Slots tot/avail | Bays tot avail | Hot Swap Bays tot avail |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0EN | Open Bay | - | - | 49.5G | 40.5G | F/W HS | F/W | 166 | 1/6 | 512/512 | 128/1GB ECC | 7/6 PCI/MC shared | 22/20 | 18/18 |
| 0E1 | Open Bay | - | - | 49.5G | 40.5G | F/W HS | F/W | 166 | 1/6 | 512/512 | 128/1GB ECC | 7/6 PCI/MC shared | 22/20 | 18/18 |
| 2E1 | 2x2.25G | 8.0 | 7200 | 49.5G | 40.5G | F/W HS | F/W RAID | 166 | 2/6 | 512/512 | 128/1GB ECC | 7/6 PCI/MC shared | 22/18 | 18/16 |
| 0DN | Open Bay | - | - | 49.5G | 40.5G | F/W HS | F/W | 133 | 1/6 | 512/512 | 64/1GB ECC | 7/6 PCI/MC shared | 22/20 | 18/18 |
| 0D0 | Open Bay | - | - | 49.5G | 40.5G | F/W HS | F/W | 133 | 1/6 | 512/512 | 64/1GB ECC | 7/6 PCI/MC shared | 22/20 | 18/18 |
| 2DS | 2x2.25G | 8.0 | 7200 | 49.5G | 40.5G | F/W HS | F/W RAID | 166 | 2/6 | 512/512 | 64/1GB ECC | 7/6 PCI/MC shared | 22/18 | 18/16 |
| 0Z0 | Open Bay | - | - | 49.5G | 40.5G | F/W HS | F/W | 100 | 1/6 | 512/512 | 64/1GB ECC | 7/6 PCI/MC shared | 22/20 | 18/18 |
| 1Z0 | Open Bay | - | - | 49.5G | 40.5G | F/W HS | F/W RAID | 100 | 1/6 | 512/512 | 64/1GB ECC | 7/6 PCI/MC shared | 22/20 | 18/18 |
| 2ZS | 2x2.25G | 8.0 | 7200 | 49.5G | 40.5G | F/W HS | F/W RAID | 100 | 2/6 | 512/512 | 64/1GB ECC | 7/6 PCI/MC shared | 22/18 | 18/16 |
| 4ZS | 4x2.25G | 8.0 | 7200 | 49.5G | 40.5G | F/W HS | F/W RAID | 100 | 4/6 | 512/512 | 64/1GB ECC | 7/6 PCI/MC shared | 22/16 | 18/14 |
| M0Z | Open Bay | - | - | - | - | - | - | 100 | - | - | - | PCI/MC | - | - |
PC Server 704 - 8650
| Mod | Std. Capacity | Seek Time ms | RPM | Max. Cap. GB | Hot Swap max. Cap. | Std. HD I/F | SCSI-2 Ctrl | Pent Proc MHz | SMP std max | L2 Cache Std max | Mem std. max. (MB unless noted) | Exp. Slots tot/avail | Bays tot avail | Hot Swap Bays tot avail |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 4BW | 2x2.14G | 9.0 | 7200 | 25.68G | 25.68G | F/W HS | 2xF/W | 166 Pro | 1/4 | 512/512 | 64/1GB ECC | 6/5 PCI,4/4 EISA | 17/13 | 12/10 |
| 7AX | 4x2.14G | 9.0 | 7200 | 25.68G | 25.68G | F/W HS | F/W RAID 2xF/W | 166 Pro | 2/4 | 512/512 | 128/1GB ECC | 6/5 PCI,4/4 EISA | 17/11 | 12/8 |
PC Server 500 - 8641
| Mod | Std. Capacity | Seek Time ms | RPM | max. Cap. GB | Hot Swap max. Cap. | Std. HD I/F | SCSI-2 Ctrl | Pent Proc MHz | SMP std max | L2 Cache Std max | Mem std. max. (MB unless noted) | Exp. Slots tot/avail | Bays tot avail | Hot Swap Bays tot avail | Remark |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0RT | 1x1.0G | - | - | - | - | - | - | 90 | - | - | 16 | - | - | - | Ethernet -or- Token |
| 3RT | 3x1G | - | - | - | - | - | RAID | 90 | - | - | 16 | - | - | - | Ethernet -or- Token |
| S0C | - | - | - | - | - | - | - | 90 | - | - | 16 ECC | - | - | - | - |
| MYS | 3x2.25G | - | - | - | - | - | - | 90 | - | - | 32 | - | - | - | - |
| MY0 | - | - | - | - | - | - | - | 90 | - | - | 32 | - | - | - | - |
| NYV | 1x2.25G | - | - | - | - | - | - | 90 | - | - | 32 | - | - | - | - |
| NY0 | - | - | - | - | - | - | - | 90 | - | - | 32 | - | - | - | - |
PC Server 520 - 8641
| Mod | Std. Capacity | Seek Time ms | RPM | max. Cap. GB | Hot Swap max. Cap. | Std. HD I/F | SCSI-2 Ctrl | Pent Proc MHz | SMP std max | L2 Cache Std max | Mem std. max. (MB unless noted) | Exp. Slots tot/avail | Bays tot avail | Hot Swap Bays tot avail |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| EZ0 | Open Bay | - | - | - | - | - | - | 100 | - | - | 32 | PCI/EISA | - | - |
| EZV | 1x2.25G | - | - | - | - | - | - | 100 | - | - | 32 | PCI/EISA | - | - |
| EZE | 4x2.25G | - | - | - | - | - | RAID | 100 | - | - | 32 | PCI/EISA | - | - |
| EZS | 2x2.25G | - | - | - | - | - | RAID | 100 | - | - | 32 | PCI/EISA | - | - |
| EE0 | Open Bay | - | - | 49.5G | 40.5G | F/W HS | F/W | 166z | 1/2 | 512/512 | 64/256 ECC | 2/2 PCI,5/4 EISA | 22/20 | 18/18 |
| EE1 | Open Bay | - | - | 49.5G | 40.5G | F/W HS | F/W RAID | 166z | 1/2 | 512/512 | 64/256 ECC | 2/2 PCI,5/4 EISA | 22/20 | 18/18 |
| EEE | 4x2.25G | 8.0 | 7200 | 49.5G | 40.5G | F/W HS | F/W RAID | 166z | 1/2 | 512/512 | 64/256 ECC | 2/2 PCI,5/4 EISA | 22/16 | 18/14 |
| EEL | 6x2.25G | 8.0 | 7200 | 49.5G | 40.5G | F/W HS | F/W RAID | 166z | 1/2 | 512/512 | 64/256 ECC | 2/2 PCI,5/4 EISA Quad Peermaster Ethernet | 22/14 | 18/12 |
| MD2 | Open Bay | - | - | 49.5G | 40.5G | F/W HS | F/W RAID F/W F | 133 | 1/2 | 512/512 | 32/256 ECC | 2/1 PCI,6/6 MC | 22/20 | 18/18 |
| MDG | 4x2.25G | 8.0 | 7200 | 49.5G | 40.5G | F/W HS | F/W RAID F/W F | 133 | 1/2 | 512/512 | 32/256 ECC | 2/1 PCI,6/6 MC | 22/16 | 18/14 |
| ED2 | Open Bay | - | - | 49.5G | 40.5G | F/W HS | F/W RAID | 133 | 1/2 | 512/512 | 32/256 ECC | 2/2 PCI,5/4 EISA | 22/20 | 18/18 |
| EDG | 4x2.25G | 8.0 | 7200 | 49.5G | 40.5G | F/W HS | F/W RAID | 133 | 1/2 | 512/512 | 32/256 ECC | 2/2 PCI,5/4 EISA | 22/16 | 18/14 |
| MZ0 | Open Bay | - | - | 49.5G | 40.5G | F/W HS | F/W F | 100x | 1/2 | 512/512 | 32/256 ECC | 2/2 PCI,6/6 MC | 22/20 | 18/18 |
| MZL | 6x2.25G | - | - | - | - | - | - | 100 | 32 | PCI/MC | ||||
| MZV | 1x2.25G | 8.0 | 7200 | 49.5G | 40.5G | F/W HS | F/W F | 100x | 1/2 | 512/512 | 32/256 ECC | 2/2 PCI,6/6 MC | 22/19 | 18/17 |
| MZS | 2x2.25G | 8.0 | 7200 | 49.5G | 40.5G | F/W HS | F/W RAID F/W F | 100x | 1/2 | 512/512 | 32/256 ECC | 2/1 PCI,6/6 MC | 22/18 | 18/16 |
| MZE | 4x2.25G | 8.0 | 7200 | 49.5G | 40.5G | F/W HS | F/W RAID F/W F | 100x | 1/2 | 512/512 | 32/256 ECC | 2/1 PCI,6/6 MC | 22/16 | 18/14 |
| EZ0 | Open Bay | - | - | 49.5G | 40.5G | F/W HS | F/W F | 100x | 1/2 | 512/512 | 32/256 ECC | 2/2 PCI,5/4 EISA | 22/20 | 18/18 |
| EZV | 1x2.25G | 8.0 | 7200 | 49.5G | 40.5G | F/W HS | F/W F | 100x | 1/2 | 512/512 | 32/256 ECC | 2/2 PCI,5/4 EISA | 22/19 | 18/17 |
| EZS | 2x2.25G | 8.0 | 7200 | 49.5G | 40.5G | F/W HS | F/W RAID | 100x | 1/2 | 512/512 | 32/256 ECC | 2/2 PCI,5/4 EISA | 22/18 | 18/16 |
| EZE | 4x2.25G | 8.0 | 7200 | 49.5G | 40.5G | F/W HS | F/W RAID | 100x | 1/2 | 512/512 | 32/256 ECC | 2/2 PCI,5/4 EISA | 22/16 | 18/14 |
| MZL | 6x2.25G | 8.0 | 7200 | 49.5G | 40.5G | F/W HS | F/W RAID F/W F | 100x | 1/2 | 512/512 | 32/256 ECC | 2/2 PCI,6/5 MC Quad Peermaster Ethernet | 22/14 | 18/12 |
| SEZ | Open Bay | - | - | - | - | - | - | 100 | - | - | - | EISA | - | - |
| SMZ | Open Bay | - | - | - | - | - | - | 100 | - | - | - | MC | - | - |
PC Server 320 - 8640
| Mod | Std. Capacity | Seek Time ms | RPM | Max. Cap. GB | Hot Swap max. Cap. | Std. HD I/F | SCSI-2 Ctrl | Pent Proc MHz | SMP std max | L2 Cache Std max | Mem std. max. (MB unless noted) | Exp. Slots tot/avail | Bays tot avail | Hot Swap Bays tot avail |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CY0 | Open Bay | - | - | - | - | - | - | 90 | - | - | 16 | PCI/EISA | - | - |
| CYR | 2x1.12G | - | - | - | - | - | - | 90 | - | - | 16 | PCI/EISA | - | - |
| CYT | 1x1.12G | - | - | - | - | - | - | 90 | - | - | 16 | PCI/EISA | - | - |
| M0C | Open Bay | - | - | - | - | - | - | 90 | - | - | - | PCI/EISA | - | - |
| 0X0 | Open Bay | - | - | - | - | - | - | 75 | - | - | 16 | PCI/EISA | - | - |
| 0XT | 1x1.08G | - | - | - | - | - | - | 75 | - | - | 16 | PCI/EISA | - | - |
| S1X | Open Bay | - | - | - | - | - | - | 75 | - | - | - | PCI/EISA | - | - |
| MX0 | Open Bay | - | - | - | - | - | - | 75 | - | - | 16 | PCI/MC | - | - |
| MXT | 1x1.08G | - | - | - | - | - | - | 75 | - | - | 16 | PCI/MC | - | - |
| S0X | Open Bay | - | - | - | - | - | - | 75 | - | - | - | PCI/MC | - | - |
| MY0 | Open Bay | - | - | - | - | - | - | 90 | - | - | 16 | PCI/MC | - | - |
| MYR | 2x1.12G | - | - | - | - | - | RAID | 90 | - | - | 16 | PCI/MC | - | - |
| MYT | 1x1.12G | - | - | - | - | - | - | 90 | - | - | 16 | PCI/MC | - | - |
| S0Y | Open Bay | - | - | - | - | - | - | 90 | - | - | - | PCI/MC | - | - |
| EE0 | Open Bay | - | - | 27.0G | Opt. | F/W | F/W F | 166z | 1/2 | 256/512 | 32/256 ECC | 2/2 PCI,5/4 EISA | 9/7 | Opt. |
| EEV | 1x2.25G | 8.0 | 7200 | 27.0G | Opt. | F/W | F/W F | 166z | 1/2 | 256/512 | 32/256 ECC | 2/2 PCI,5/4 EISA | 9/6 | Opt. |
| EE1 | Open Bay | - | - | 18.0G | 13.5G | F/W HS | F/W RAID | 166z | 1/2 | 256/512 | 32/256 ECC | 2/2 PCI,5/4 EISA | 10/8 | 6/6 |
| EES | 2x2.25G | 8.0 | 7200 | 18.0G | 13.5G | F/W HS | F/W RAID | 166z | 1/2 | 256/512 | 32/256 ECC | 2/2 PCI,5/4 EISA | 10/6 | 6/4 |
| 2D0 | Open Bay | - | - | 27.0G | Opt. | F/W | F/W F | 133 | 1/2 | 256/512 | 32/256 ECC | 2/2 PCI,5/4 EISA | 9/7 | Opt. |
| 0D0 | Open Bay | - | - | 27.0G | Opt. | F/W | F/W F | 133 | 1/2 | 256/512 | 16/256 Par y | 2/2 PCI,5/4 EISA | 9/7 | Opt. |
| 0DV | 1x2.25G | 8.0 | 7200 | 27.0G | Opt. | F/W | F/W F | 133 | 1/2 | 256/512 | 16/256 Par y | 2/2 PCI,5/4 EISA | 9/6 | Opt. |
| 3D0 | Open Bay | - | - | 18.0G | 13.5G | F/W HS | F/W RAID | 133 | 1/2 | 256/512 | 32/256 ECC | 2/2 PCI,5/4 EISA | 10/8 | 6/6 |
| 1D0 | Open Bay | - | - | 18.0G | 13.5G | F/W HS | F/W RAID | 133 | 1/2 | 256/512 | 16/256 Par y | 2/2 PCI,5/4 EISA | 10/8 | 6/6 |
| 1DS | 2x2.25G | 8.0 | 7200 | 18.0G | 13.5G | F/W HS | F/W RAID | 133 | 1/2 | 256/512 | 16/256 Par y | 2/2 PCI,5/4 EISA | 10/6 | 6/4 |
| MD2 | Open Bay | - | - | 15.7G | 13.5G | F/W HS | F/W F | 133 | 1/2 | 256/512 | 32/256 ECC | 2/2 PCI,6/6 MC | 9/7 | 6/6 |
| MD0 | Open Bay | - | - | 15.7G | 13.5G | F/W HS | F/W F | 133 | 1/2 | 256/512 | 16/256 Par y | 2/2 PCI,6/6 MC | 9/7 | 6/6 |
| MDV | 1x2.25G | 8.0 | 7200 | 15.7G | 13.5G | F/W HS | F/W F | 133 | 1/2 | 256/512 | 16/256 Par y | 2/2 PCI,6/6 MC | 9/6 | 6/5 |
| MDS | 2x2.25G | 8.0 | 7200 | 15.7G | 13.5G | F/W HS | F/W RAID F/W F | 133 | 1/2 | 256/512 | 16/256 Par y | 2/1 PCI,6/6 MC | 9/5 | 6/4 |
| 2Z0 | Open Bay | - | - | 27.0G | Opt. | F/W | F/W F | 100x | 1/2 | 256/512 | 32/256 ECC | 2/2 PCI,5/4 EISA | 9/7 | Opt. |
| 0Z0 | Open Bay | - | - | 27.0G | Opt. | F/W | F/W F | 100x | 1/2 | 256/512 | 16/256 Par y | 2/2 PCI,5/4 EISA | 9/7 | Opt. |
| 0ZV | 1x2.25G | 8.0 | 7200 | 27.0G | Opt. | F/W | F/W F | 100x | 1/2 | 256/512 | 16/256 Par y | 2/2 PCI,5/4 EISA | 9/6 | Opt. |
| 3Z0 | Open Bay | - | - | 18.0G | 13.5G | F/W HS | F/W RAID | 100x | 1/2 | 256/512 | 32/256 ECC | 2/2 PCI,5/4 EISA | 10/8 | 6/6 |
| 1Z0 | Open Bay | - | - | 18.0G | 13.5G | F/W HS | F/W RAID | 100x | 1/2 | 256/512 | 16/256 Par y | 2/2 PCI,5/4 EISA | 10/8 | 6/6 |
| MZ2 | Open Bay | - | - | 15.7G | 13.5G | F/W HS | F/W F | 100x | 1/2 | 256/512 | 32/256 ECC | 2/2 PCI,6/6 MC | 9/7 | 6/6 |
| MZ0 | Open Bay | - | - | 15.7G | 13.5G | F/W HS | F/W F | 100x | 1/2 | 256/512 | 16/256 Par y | 2/2 PCI,6/6 MC | 9/7 | 6/6 |
| MZV | 1x2.25G | 8.0 | 7200 | 15.7G | 13.5G | F/W HS | F/W F | 100x | 1/2 | 256/512 | 16/256 Par y | 2/2 PCI,6/6 MC | 9/6 | 6/5 |
| MZ1 | Open Bay | - | - | 15.7G | 13.5G | F/W HS | F/W RAID F/W F | 100x | 1/2 | 256/512 | 16/256 Par y | 2/1 PCI,6/6 MC | 9/7 | 6/6 |
PC Server 310 - 8639
| Mod | Std. Capacity | Seek Time ms | RPM | Max. Cap. GB | Hot Swap max. Cap. | Std. HD I/F | SCSI-2 Ctrl | Pent Proc MHz | SMP std max | L2 Cache Std max | Mem std. max. (MB unless noted) | Exp. Slots tot/avail | Bays tot avail | Hot Swap Bays tot avail |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0XT | 1x1.08G | - | - | - | - | - | - | 75 | - | - | 16 | PCI/ISA | - | - |
| MXT | 1x1.08G | - | - | - | - | - | - | 75 | - | - | 16 | PCI/MC | - | - |
| 0Z0 | Open Bay | - | - | 6.7G | - | F | F | 100x | - | 256/256 | 16/192 Par y | 5/3 PCI/ISA | 5/3 | - |
| 0ZT | 1x1.27G | 11 | 5400 | 6.7G | - | F | F | 100x | - | 256/256 | 16/192 Par y | 5/3 PCI/ISA | 5/2 | - |
| 0D0 | Open Bay | - | - | 6.7G | - | F | F | 133 | - | 256/256 | 16/192 Par y | 5/3 PCI/ISA | 5/3 | - |
| 0DT | 1x1.27G | 11 | 5400 | 6.7G | - | F | F | 133 | - | 256/256 | 16/192 Par y | 5/3 PCI/ISA | 5/2 | - |
PC Server 300 - 8640
| Mod | Std. Capacity | Seek Time ms | RPM | Max. Cap. GB | Hot Swap max. Cap. | Std. HD I/F | SCSI-2 Ctrl | Pent Proc MHz | SMP std max | L2 Cache Std max | Mem std. max. (MB unless noted) | Exp. Slots tot/avail | Bays tot avail | Hot Swap Bays tot avail |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1N0 | - | - | - | - | - | F | - | 486 DX2 66 |
- | - | 8 | PCI/EISA | - | - |
| 1NJ | 1x728M | - | - | - | - | F | - | 486 DX2 66 |
- | - | 8 | PCI/ISA | - | - |
| 1NT | 1x1.0G | - | - | - | - | - | F-PCI | 486 DX2 66 |
- | - | 16 | PCI/ISA | - | - |
| CNT | 1x1.0G | - | - | - | - | - | F-PCI | 486 DX2 66 |
- | - | 16 | PCI/ISA | - | - |
| 1P0 | - | - | - | - | - | F | - | 60 | - | - | 16 | PCI/ISA | - | - |
| 1PT | 1x1.0G | - | - | - | - | F | F-PCI | 60 | - | - | 16 | PCI/ISA | - | - |
| CPT | 1x1.0G | - | - | - | - | F | - | 60 | - | - | 16 | PCI/ISA | - | - |
Please see the LEGAL - Trademark notice.
Feel free - send a
for any BUG on this page found - Thank you.