0DDDPLST
--+||||
||||+-------- Type of RAID controller
|||| 0 = RAID Controller
|||| 1 = IBM Fast/Wide Streaming RAID Adapter/A
||||
|||+-------- System slot number for the controller
|||
||+-------- Device LUN (value is always 0)
||
|+-------- Device PUN (value is always 7)
|
+--------- 270 indentifies that the failure is in the
RAID controller.
Information relative to the failure mechanism experienced is encoded within the
Failure ID that's included in the diagnostic's error message.
The Failure Id is of the form:
TTEE
-+---+
| |
| +------- Identifies the error and is taken from E & F
| registers of the shared register set of the MIAMI
| chip.
|
+---------- Test number
TT = 00 Memory Tests (DRAM)
01 DRAM Test
10 Transfer logic test
11 MIAMI chip test
14 Loopback test (through system memory)
20 SCSI I/O processor test
21 SIOP data test
22 SIOP address test
26 SIOP local loopback test
30 SIOP/SCSI-Bus test
31 SCSI Cable test
32 SCSI Parity test
40 MIAMI loopback test
RAID Logical Drive Errors x2710yyL
02710RSL
|||
||+---- RAID Logical Drive Return Code
|| 0002 = One or more of the SCSI disks on which the
|| systemdrive is dependent does not respond.
|| 0004 = Invalid systemdrive or attempt to check
|| non-redundant system drive (RAID 0).
||
|| All other = Logical drive test failed, resynchronization
|| required
||
|+---- System slot number for the device
|
+---- Logical drive number
RAID Device Errors x271xxxx
0271BCSP
||||
|||+---- Device ID or PUN number of the device
|||
||+---- System slot number for the device
||
|+---- Channel number of the device
|
+---- Bay number of the device
BCSP = 0002 Check condition, bad command
0003 Request sense invalid status or bad command
0005 Zero size, bad command
0006 Bad block, read-verify test fail
000A Timeout, bad command
000F Unknown error, access problem, hard disk
not responding.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.