IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
Power-on Sequence / 3518
Power-on Sequence (Type 3518)
Note: The expansion enclosure can be powered on without connecting it to a server.
However, the expansion enclosure must be connected to a server before the drives installed in the enclosure can be used.
To power-on the expansion enclosure, do the following:
- Locate the keys, then unlock and open the door on the front of the expansion enclosure.
- If the server is powered-on, power it off.
- Lift the transparent Power Enable Switch cover on the front panel and press the Power Enable Switch, the Power OK indicator will illuminate.
- Then, press the Power On/Off switch (located just above the Power Enable Switch). The information panel will display IBM 3518
- Power-on the server. Then power-on self-test (POST) begins.
- Check the monitor connected to the server. The screen displays the IBM logo and a number that represents the amount of available server menory.
The server beeps once to indicate that it is working properly.
Note:
- If you hear more than one beep or no beep, check the monitor and the information panel.
- If an error message appears on the information panel or the expansion enclosure stops running durin testing or normal operation, see
Symptom-to-FRU Index (Type 3518).
- If an error message appears on the monitor screen, the monitor screen is blank, or the server stops during normal operation, refer
to the diagnostic information for the server.