Size
- Depth: 445 mm (17.5 in.)
- Height: 492 mm (19.4 in.)
- Width: 200 mm ( 7.9 in.)
Weight
° Maximum configuration (as shipped): 17.3 kg (38 lb)
° Standard configuration (as shipped): 15.0 kg (33 lb)
Environment
° Air temperature:
- Server on: 10° to 35° C (50° to 95° F) at altitude 0-915 m (0-3000 ft)
10° to 32° C (50° to 90° F) at altitude 915-2134 m (3000-7000 ft)
- Server off: 10° to 43° C (50° to 110° F)
° Humidity:
- Server on: 8% to 80%
- Server off: 8% to 80%
Electrical Input
° Sine-wave input (50 to 60 Hz) is required
° Input voltage:
- Low range:
- Minimum: 90 V ac
- Maximum: 137 V ac
- High range:
- Minimum: 180 V ac
- Maximum: 265 V ac
- Input kilovolt-amperes (kVA) approximately:
- Maximum configuration: 0.70 kVA
Heat Output
° Approximate heat output in British Thermal Units (BTU) per hour:
- Minimum configuration: (as shipped) 306 BTU (90 watts)
- Maximum configuration: (theoretical) 1564 BTU (460 watts)
Acoustical Noise-Emission Values
° Average sound-pressure levels:
- At operator position:
- 42 dBA idle
- 46 dBA operating
- At bystander position - 1 meter (3.3 ft):
- 36 dBA idle
- 40 dBA operating
° Declared (upper limit) sound-power levels:
- 5.1 bels idle
- 5.5 bels operating
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.