Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

RAID POST Error Codes (Server 330 - x1Y, Pxx)



RAID POST Error Codes (Server 330 - x1Y, Pxx)

Once the RAID test has completed, the following register information is displayed on the screen before returning to the Diagnostic Control program:

Hdwr: ISPR= aaaa BCS= bb ECS= cc

The number aaaa is the controller POST, it should normally read EF10 which indicates NO ERROR BCS and ECS are configuration registers.

NOTE: For a full list of the BCS ECS configuration error messages, refer to the manual for the RAID adapter.

Error Code    FRU/Action
  
1XXX 1. System Board
ServeRAID POST - Flash Checksum error
2XXX 1. System Board
ServeRAID POST - Code DRAM error
3XXX 1. System Board
ServeRAID POST - NVRAM error
4XXX 1. System Board
ServeRAID POST - Time/Cache
Memory Controller error
5XXX 1. System Board
ServeRAID POST - Cache
Memory Controller error
6XXX 1. System Board
ServeRAID POST - Cache DRAM error
7XXX 1. System Board
ServeRAID POST - Host/Local
PCI Bus Interface error
8XXX 1. System Board
ServeRAID POST - SCSI IOP error
9XXX 1. System Board
ServeRAID POST - SCSI
Termination error
AXXX 1. System Board
ServeRAID POST - SCSI IOP error
BXXX 1. Cable
ServeRAID POST - SCSI 2. System Board
Bus Interface error


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.