| POST Error Code/Symptom | FRU/Action |
|---|---|
| 101 | 1. System Board |
| (Timer tick interrupt failure) | 2. Microprocessor |
| 102 | 1. System Board |
| (Timer 2 test failure) | 2. Microprocessor |
| 106 | 1. System Board |
| (Diskette controller failure) | 2. Microprocessor |
| 112 | 1. System Board |
| (I2C interface hardware error) | 2. Microprocessor Card |
| 3. Microprocessor | |
| 114 | 1. Failing Adapter |
| (Option read only memory | 2. Run Diagnostics |
| checksum failure) | |
| 115 | 1. System Board |
| (Boot block checksum error) | 2. Microprocessor Card |
| 116 | 1. System Board |
| (Application processor failure) | 2. Microprocessor Card |
| 151 | 1. Run Diagnostics |
| (Real time clock error) | 2. Real-Time Clock or Battery |
| 3. System Board | |
| 161 | 1. Run Configuration/Setup |
| (Invalid configuration information | then, run the EISA Configuration Utility |
| or CMOS RAM checksum failure) | 2. Failing Device |
| 3. Battery/CMOS Chip | |
| 4. System Board | |
| 162 | 1. Run Configuration/Setup |
| (Invalid configuration | 2. Failing Device |
| information or CMOS RAM | 3. Battery/CMOS Chip |
| checksum failure) | 4. System Board |
| 163 | 1. Run Configuration/Setup |
| (Time of Day not set) | 2. Battery/CMOS Chip |
| 3. System Board | |
| 164 | 1. Run Configuration/Setup |
| (Memory size does not match CMOS) | 2. DIMM |
| 3. Microprocessor Card | |
| 173 | 1. Run Configuration/Setup |
| (System EEPROM checksum bad) | 2. Battery/CMOS Chip |
| 3. System Board | |
| 175 | 1. System board |
| (System EEPROM checksum bad) | 2. Microprocessor Card |
| 176 | 1. Run Configuration/Setup |
| (Computer cover or cable cover | |
| was removed without a key | |
| being used) | |
| 177 | 1. System Board |
| (Bad Administrator Password | |
| checksum) | |
| 178 | 1. System Board |
| (EEPROM is not functional) | |
| 183 | 1. Run Configuration/Setup |
| (PAP is required) | |
| 184 | 1. Run Configuration/Setup |
| (Power-on password corrupted) | 2. System board |
| 185 | 1. Run Configuration/Setup |
| (Drive startup sequence | 2. System board |
| information corrupted) | |
| 186 | 1. Run Configuration/Setup |
| (System board or security | 2. System Board |
| hardware error) | |
| 187 | 1. Set vital product data |
| (Vital Product Data S/N | 2. System Board |
| not set) | |
| 188 | 1. System board |
| (Bad EEPROM cyclic redundancy | |
| check 2) | |
| 189 | 1. Run Configuration/Setup, enter the |
| (Excessive password attempts) | administrator password |
| 201 | 1. DIMM |
| (Base or extended memory error) | 2. Processor Card |
| 3. System Board | |
| 301 | 1. Keyboard |
| (Keyboard or keyboard controller error) | 2. System Board |
| 303 | 1. Systemboard |
| (Keyboard controller failure) | 2. Keyboard |
| 604 | 1. Run Configuration/Setup and Diagnostics |
| (Diskette drive 0 or 1 failure) | 2. Diskette Drive |
| 3. Diskette Drive Cable | |
| 4. System Board | |
| 662 | 1. Run Configuration/Setup and Diagnostics |
| (Diskette drive configuration error) | 2. Diskette Drive |
| 3. Diskette Drive Cable | |
| 4. System Board | |
| 962 | 1. Disconnect external cable on parallel port |
| (Parallel port configuration error) | 2. Run Configuration/Setup |
| 3. System Board | |
| 11XX | 1. Disconnect external cable on serial port |
| (Serial port configuration error) | 2. Run Configuration/Setup |
| 3. System board | |
| 1800 | 1. Run Configuration/Setup |
| (No more hardware interrupt | 2. Run EISA Configuration |
| available) | 3. Failing Adapter |
| 4. System Board | |
| 1801 | 1. Run Configuration/Setup |
| (No more room for option ROM) | 2. Run EISA Configuration |
| 3. Failing Adapter | |
| 4. System Board | |
| 1802 | 1. Run Configuration/Setup |
| (No more I/O space available | 2. Failing Adapter |
| 3. System Board | |
| 1803 | 1. Run Configuration/Setup |
| (No more memory | 2. Failing Adapter |
| above 1 MB available) | 3. System Board |
| 1804 | 1. Run Configuration/Setup |
| (No more memory | 2. Move failing adapter to slot 1 or 2 |
| below 1 MB available) | 3. Failing Adapter |
| 4. System Board | |
| 1805 | 1. Remove Failing PCI Card |
| (Checksum error or 0 size | 2. System Board |
| option ROM) | |
| 1806 | 1. Run Configuration/Setup |
| (PCI to PCI Bridge error) | 2. Move failing adapter to slot 1 or 2 |
| 3. Failing Adapter | |
| 4. System Board | |
| 1962 | 1. Run Configuration/Setup |
| (No valid startup devices | 2. System Board |
| were found) | |
| 2400 | 1. Video Adapter (if installed) |
| (Display adapter failed, | 2. System Board |
| using alternate) | |
| 2462 | 1. Video Adapter (if installed) |
| (Video configuration error) | 2. System Board |
| 8601 8602 | 1. Pointing Device |
| (Pointing Device failure) | 2. System Board |
| 8603 | 1. Pointing Device |
| (Pointing Device has been | 2. System Board |
| removed) | |
| 000120P0 | 1. Microprocessor Board |
| (Primary microprocessor | |
| cache failure) | |
| 000120P1 | 1. Microprocessor Board |
| (Secondary microprocessor | 2. System Board |
| cache failure) | |
| 01298001 | 1. Update BIOS |
| (No update data for boot | |
| processor) | |
| 01298002 | 1. Update BIOS |
| (No update data for application | |
| processor) | |
| 01298003 | 1. Update BIOS |
| (Bad update data for boot | 2. System Board |
| processor) | |
| 01298004 | 1. Update BIOS |
| (Bad update data for application | 2. System Board |
| processor) | |
| I9990301 | 1. Run Configuration/Setup for correct startup |
| (Fixed boot disk error) | 2. Fixed disk drive |
Please see the LEGAL - Trademark notice.