Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

POST Error Codes (Server 330 - x1Y, Pxx)



Error Codes (Server 330 - x1Y, Pxx)

In the following error codes, can be any number or letter.

POST Error Code/Symptom    FRU/Action
  
101 1. System Board
(Timer tick interrupt failure) 2. Microprocessor
  
102 1. System Board
(Timer 2 test failure) 2. Microprocessor
  
106 1. System Board
(Diskette controller failure) 2. Microprocessor
  
112 1. System Board
(I2C interface hardware error) 2. Microprocessor Card
  3. Microprocessor
  
114 1. Failing Adapter
(Option read only memory 2. Run Diagnostics
checksum failure)
115 1. System Board
(Boot block checksum error) 2. Microprocessor Card
  
116 1. System Board
(Application processor failure) 2. Microprocessor Card
  
151 1. Run Diagnostics
(Real time clock error) 2. Real-Time Clock or Battery
  3. System Board
  
161 1. Run Configuration/Setup
(Invalid configuration information     then, run the EISA Configuration Utility
or CMOS RAM checksum failure) 2. Failing Device
  3. Battery/CMOS Chip
  4. System Board
  
162 1. Run Configuration/Setup
(Invalid configuration 2. Failing Device
information or CMOS RAM 3. Battery/CMOS Chip
checksum failure) 4. System Board
  
163 1. Run Configuration/Setup
(Time of Day not set) 2. Battery/CMOS Chip
  3. System Board
  
164 1. Run Configuration/Setup
(Memory size does not match CMOS) 2. DIMM
  3. Microprocessor Card
  
173 1. Run Configuration/Setup
(System EEPROM checksum bad) 2. Battery/CMOS Chip
  3. System Board
  
175 1. System board
(System EEPROM checksum bad) 2. Microprocessor Card
  
176 1. Run Configuration/Setup
(Computer cover or cable cover
was removed without a key
being used)
177 1. System Board
(Bad Administrator Password
checksum)
178 1. System Board
(EEPROM is not functional)
183 1. Run Configuration/Setup
(PAP is required)
184 1. Run Configuration/Setup
(Power-on password corrupted) 2. System board
  
185 1. Run Configuration/Setup
(Drive startup sequence 2. System board
information corrupted)
186 1. Run Configuration/Setup
(System board or security 2. System Board
hardware error)
187 1. Set vital product data
(Vital Product Data S/N 2. System Board
not set)
188 1. System board
(Bad EEPROM cyclic redundancy
check 2)
189 1. Run Configuration/Setup, enter the
(Excessive password attempts)     administrator password
  
201 1. DIMM
(Base or extended memory error) 2. Processor Card
  3. System Board
  
301 1. Keyboard
(Keyboard or keyboard controller error) 2. System Board
  
303 1. Systemboard
(Keyboard controller failure) 2. Keyboard
  
604 1. Run Configuration/Setup and Diagnostics
(Diskette drive 0 or 1 failure) 2. Diskette Drive
  3. Diskette Drive Cable
  4. System Board
  
662 1. Run Configuration/Setup and Diagnostics
(Diskette drive configuration error) 2. Diskette Drive
  3. Diskette Drive Cable
  4. System Board
  
962 1. Disconnect external cable on parallel port
(Parallel port configuration error) 2. Run Configuration/Setup
  3. System Board
  
11XX 1. Disconnect external cable on serial port
(Serial port configuration error) 2. Run Configuration/Setup
  3. System board
  
1800 1. Run Configuration/Setup
(No more hardware interrupt 2. Run EISA Configuration
available) 3. Failing Adapter
  4. System Board
  
1801 1. Run Configuration/Setup
(No more room for option ROM) 2. Run EISA Configuration
  3. Failing Adapter
  4. System Board
  
1802 1. Run Configuration/Setup
(No more I/O space available 2. Failing Adapter
  3. System Board
  
1803 1. Run Configuration/Setup
(No more memory 2. Failing Adapter
above 1 MB available) 3. System Board
  
1804 1. Run Configuration/Setup
(No more memory 2. Move failing adapter to slot 1 or 2
below 1 MB available) 3. Failing Adapter
  4. System Board
  
1805 1. Remove Failing PCI Card
(Checksum error or 0 size 2. System Board
option ROM)
1806 1. Run Configuration/Setup
(PCI to PCI Bridge error) 2. Move failing adapter to slot 1 or 2
  3. Failing Adapter
  4. System Board
  
1962 1. Run Configuration/Setup
(No valid startup devices 2. System Board
were found)
2400 1. Video Adapter (if installed)
(Display adapter failed, 2. System Board
using alternate)
2462 1. Video Adapter (if installed)
(Video configuration error) 2. System Board
  
8601 8602 1. Pointing Device
(Pointing Device failure) 2. System Board
  
8603 1. Pointing Device
(Pointing Device has been 2. System Board
removed)
000120P0 1. Microprocessor Board
(Primary microprocessor
cache failure)
000120P1 1. Microprocessor Board
(Secondary microprocessor 2. System Board
cache failure)
01298001 1. Update BIOS
(No update data for boot
processor)
01298002 1. Update BIOS
(No update data for application
processor)
01298003 1. Update BIOS
(Bad update data for boot 2. System Board
processor)
01298004 1. Update BIOS
(Bad update data for application 2. System Board
processor)
I9990301 1. Run Configuration/Setup for correct startup
(Fixed boot disk error) 2. Fixed disk drive


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.