Size
° With pedestal:
- Depth: 473 mm (18.6 in.)
- Height: 652 mm (25.6 in.)
- Width: 315 mm (12.4 in.)
Weight
° Typical server as shipped: 19.0 kg (42.0 lb)
Total Power Available for Drives
° Nominal Operating Current allowed:
- +5 Vdc line: 5.3 A
- +12 Vdc line: 5.0 A
Heat Output
° Approximate heat output in British Thermal Units (BTU) per hour:
- Minimum configuration: 440 BTU (129 watts)
- Maximum configuration: 1000 BTU (293 watts)
Electrical Input
° Sine-wave input (50 to 60 Hz) is required
° Input voltage:
- Low range:
- Minimum: 90 V ac
- Maximum: 137 V ac
- High range:
- Minimum: 180 V ac
- Maximum: 265 V ac
- Input kilovolt-amperes (kVA) approximately:
- Minimum configuration as shipped: 0.08 kVA
- Maximum configuration: 0.52 kVA
Environment
° Air temperature:
- Server on: 10° to 35° C (50° to 95° F)
Altitude: 0 to 914 m (3000 ft.)
- Server on: 10° to 32° C (50° to 90° F)
Altitude: 914 m (3000 ft.) to 2133 m (7000 ft.)
- Server off: 10° to 43° C (50° to 110° F)
Maximum Altitude: 2133 m (7000 ft.)
° Humidity:
- Server on: 8% to 80%
- Server off: 8% to 80%
° Maximum altitude: 2133 m (7000 ft)