IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
Removing the Power-on Password when Keylock is Installed
Removing the Power-on Password when Keylock is Installed Server 330 - x1Y, Pxx
Before you begin
- Read Safety Information
- Power-off the server
- Disconnect all external cables and power cords, and then remove the server cover
- Locate the Clear CMOS jumper (J23, pin 7)
- Verify that the keylock is connected to the system board. If no keylock
is installed, go to 'Removing the Power-On Password When Keylock is Not Installed'.
- Add a jumper to pins 2 and 3 (the pins furthest away from the microprocessor board).
- Replace the server cover and reconnect all external cables and power cords.
- Power-on the server, then, close and lock the server door.
- Power-off the server, and remove the cables.
- Remove the jumper from jumper J23-7, if you moved the jumper earlier, replace it in its original position.
- Replace the server cover and reconnect all external cables and power cords.
- Power-on the server and use the Configuration/Setup utility programs to enter a new password and reconfigure the server.
NOTE: The administrator password is not affected by this jumper.
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a