Removing the Power-on Password when Keylock is Installed



  Removing the Power-on Password when Keylock is Installed Server 330 - x1Y, Pxx
Before you begin

  1.  Locate the Clear CMOS jumper (J23, pin 7)
  2.  Verify that the keylock is connected to the system board. If no keylock  is installed, go to 'Removing the Power-On Password When Keylock is Not Installed'.
  3.  Add a jumper to pins 2 and 3 (the pins furthest away from the microprocessor board).
  4.  Replace the server cover and reconnect all external cables and power cords.
  5.  Power-on the server, then, close and lock the server door.
  6.  Power-off the server, and remove the cables.
  7.  Remove the jumper from jumper J23-7, if you moved the jumper earlier, replace it in its original position.
  8.  Replace the server cover and reconnect all external cables and power cords.
  9.  Power-on the server and use the Configuration/Setup utility programs to enter a new password and reconfigure the server.

    NOTE: The administrator password is not affected by this jumper.