| Error Code/Symptom | FRU/Action |
|---|---|
| E100, E101 | 1. Run EISA Configuration |
| (Invalid EISA configuration) | 2. Failing EISA adapter |
| 3. Real-Time Clock or Battery | |
| 4. System Board | |
| E10X | 1. Run EISA Configuration |
| (Invalid EISA configuration for Slot X) | 2. Failing EISA adapter in slot X |
| 101, 102 | 1. System Board |
| (System and microprocessor error) | 2. Microprocessor Board |
| 106 | 1. System Board |
| (System and microprocessor error) | 2. Microprocessor Board |
| 111 | 1. Failing EISA/ISA Adapter |
| (I/O channel check error) | 2. Memory DIMM |
| 3. System Board | |
| 114 | 1. Failing Adapter |
| (Adapter read-only memory error) | 2. Run Diagnostics |
| 129 | 1. Optional Microprocessor (if installed) |
| (Internal Cache error) | 2. Microprocessor |
| 3. Microprocessor Board | |
| 151 | 1. Run Diagnostics |
| (Real time clock error) | 2. Real-Time Clock or Battery |
| 3. System Board | |
| 162 | 1. Run Configuration/Setup |
| (Device Configuration Error) | then, run the EISA Configuration Utility |
| 2. Failing Device | |
| 3. Real-Time Clock or Battery | |
| 4. System Board | |
| 163 | 1. Run Configuration/Setup |
| (Real-Time Clock error) | 2. Real-Time Clock or Battery |
| 3. System Board | |
| 164 | 1. Run Configuration/Setup |
| (Memory configuration changed) | 2. DIMM |
| 3. Microprocessor Board | |
| 173 | 1. Run Configuration/Setup |
| (System CMOS checksum bad) | 2. Real-Time Clock or Battery |
| 3. System Board | |
| 175 | 1. System board |
| (Hardware error) | 2. Microprocessor Board |
| 176 | 1. Run Configuration/Setup |
| (Computer cover or cable cover | |
| was removed without a key | |
| being used) | |
| 177, 178 | 1. Run Configuration/Setup |
| (Security hardware error) | 2. System Board |
| 182 | 1. System board |
| (System board error) | |
| 183 | 1. System board |
| (Administration password not entered) | |
| 184 | 1. Run Configuration/Setup |
| (Power-on password corrupted) | 2. System board |
| 185 | 1. Run Configuration/Setup |
| (Drive startup sequence | 2. System board |
| information corrupted) | |
| 186 | 1. Run Configuration/Setup |
| (System board or security | 2. System Board |
| hardware error) | |
| 187 | 1. System board |
| (System board or security | |
| hardware error) | |
| 188 | 1. System board |
| (System board or security | |
| hardware error) | |
| 189 | 1. Run Configuration/Setup, enter the |
| (An attempt was made to access | administrator password |
| the server with invalid | |
| passwords) | |
| 201 | 1. DIMM |
| (Memory test error) | 2. Processor Board |
| 3. System Board | |
| 229 | 1. Optional Microprocessor (if installed) |
| (Cache error) | 2. Microprocessor |
| 3. Microprocessor Board | |
| 301 | 1. Keyboard |
| (Keyboard or keyboard controller error) | 2. System Board |
| 604 | 1. Run Configuration/Setup and Diagnostics |
| (Diskette drive error) | 2. Diskette Drive |
| 3. Drive Cable | |
| 4. System Board | |
| 605 | 1. Diskette Drive |
| (Diskette Unlock failure) | 2. Drive Cable |
| 3. System Board | |
| 662 | 1. Run Configuration/Setup and Diagnostics |
| (Diskette drive configuration error) | 2. Diskette Drive |
| 3. Drive Cable | |
| 4. System Board | |
| 962 | 1. Disconnect external cable on parallel port |
| (Parallel port error) | 2. Run Configuration/Setup |
| 3. System Board | |
| 11XX | 1. Disconnect external cable on serial port |
| (System-board serial port 1 or 2 error) | 2. Run Configuration/Setup |
| 3. System board | |
| 1762 | 1. Fixed Disk Cables |
| (Fixed Disk Configuration error) | 2. Run Configuration/Setup |
| 3. Fixed Disk Adapter | |
| 4. Fixed Disk Drive | |
| 5. System Board | |
| 178X | 1. Fixed Disk Cables |
| (Fixed Disk error) | 2. Run Diagnostics |
| 3. Fixed Disk Adapter | |
| 4. Fixed Disk Drive | |
| 5. System Board | |
| 1800 | 1. Run Configuration/Setup |
| (No more hardware interrupt | 2. Run EISA Configuration |
| available for PCI adapter) | 3. Failing Adapter |
| 4. System Board | |
| 1801 | 1. Run Configuration/Setup |
| (No room for PCI option ROM) | 2. Run EISA Configuration |
| 3. Failing Adapter | |
| 4. System Board | |
| 1802 | 1. Run Configuration/Setup |
| (No more I/O space available | 2. Failing Adapter |
| for PCI adapter) | 3. System Board |
| 1803 | 1. Run Configuration/Setup |
| (No more memory | 2. Failing Adapter |
| (above 1 MB for PCI adapter)) | 3. System Board |
| 1804 | 1. Run Configuration/Setup |
| (No more memory | 2. Move failing adapter to slot 1 or 2 |
| (below 1 MB for PCI adapter)) | 3. Failing Adapter |
| 4. System Board | |
| 1805 | 1. Remove Failing PCI Card |
| (PCI option ROM checksum error) | 2. System Board |
| 1806 | 1. Run Configuration/Setup |
| (PCI to PCI Bridge error) | 2. Move failing adapter to slot 1 or 2 |
| 3. Failing Adapter | |
| 4. System Board | |
| 2400 | 1. Video Adapter (if installed) |
| (Video controller test failure) | 2. System Board |
| 2462 | 1. Video Adapter (if installed) |
| (Video memory configuration error) | 2. System Board |
| 8603 | 2. Pointing Device |
| (Pointing Device Error) | 3. System Board |
| I9990301 | 1. Run Configuration/Setup for correct startup |
| (Fixed boot sector error, | 2. Verify operating system installed |
| no operating system installed) | |
| I9990305 | 1. Install operating system to hard disk drive |
| (Fixed boot sector error, | |
| no operating system installed) |