Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Error Codes (Server 325/330)



Error Codes

In the following error codes, can be any number or letter.

Error Code/Symptom    FRU/Action
  
E100, E101 1. Run EISA Configuration
(Invalid EISA configuration) 2. Failing EISA adapter
  3. Real-Time Clock or Battery
  4. System Board
  
E10X 1. Run EISA Configuration
(Invalid EISA configuration for Slot X) 2. Failing EISA adapter in slot X
  
101, 102 1. System Board
(System and microprocessor error) 2. Microprocessor Board
  
106 1. System Board
(System and microprocessor error) 2. Microprocessor Board
  
111 1. Failing EISA/ISA Adapter
(I/O channel check error) 2. Memory DIMM
  3. System Board
  
114 1. Failing Adapter
(Adapter read-only memory error) 2. Run Diagnostics
  
129 1. Optional Microprocessor (if installed)
(Internal Cache error) 2. Microprocessor
  3. Microprocessor Board
  
151 1. Run Diagnostics
(Real time clock error) 2. Real-Time Clock or Battery
  3. System Board
  
162 1. Run Configuration/Setup
(Device Configuration Error)     then, run the EISA Configuration Utility
  2. Failing Device
  3. Real-Time Clock or Battery
  4. System Board
  
163 1. Run Configuration/Setup
(Real-Time Clock error) 2. Real-Time Clock or Battery
  3. System Board
  
164 1. Run Configuration/Setup
(Memory configuration changed) 2. DIMM
  3. Microprocessor Board
  
173 1. Run Configuration/Setup
(System CMOS checksum bad) 2. Real-Time Clock or Battery
  3. System Board
  
175 1. System board
(Hardware error) 2. Microprocessor Board
  
176 1. Run Configuration/Setup
(Computer cover or cable cover
was removed without a key
being used)
177, 178 1. Run Configuration/Setup
(Security hardware error) 2. System Board
  
182 1. System board
(System board error)
183 1. System board
(Administration password not entered)
184 1. Run Configuration/Setup
(Power-on password corrupted) 2. System board
  
185 1. Run Configuration/Setup
(Drive startup sequence 2. System board
information corrupted)
186 1. Run Configuration/Setup
(System board or security 2. System Board
hardware error)
187 1. System board
(System board or security
hardware error)
188 1. System board
(System board or security
hardware error)
189 1. Run Configuration/Setup, enter the
(An attempt was made to access     administrator password
the server with invalid
passwords)
201 1. DIMM
(Memory test error) 2. Processor Board
  3. System Board
  
229 1. Optional Microprocessor (if installed)
(Cache error) 2. Microprocessor
  3. Microprocessor Board
  
301 1. Keyboard
(Keyboard or keyboard controller error) 2. System Board
  
604 1. Run Configuration/Setup and Diagnostics
(Diskette drive error) 2. Diskette Drive
  3. Drive Cable
  4. System Board
  
605 1. Diskette Drive
(Diskette Unlock failure) 2. Drive Cable
  3. System Board
  
662 1. Run Configuration/Setup and Diagnostics
(Diskette drive configuration error) 2. Diskette Drive
  3. Drive Cable
  4. System Board
  
962 1. Disconnect external cable on parallel port
(Parallel port error) 2. Run Configuration/Setup
  3. System Board
  
11XX 1. Disconnect external cable on serial port
(System-board serial port 1 or 2 error) 2. Run Configuration/Setup
  3. System board
  
1762 1. Fixed Disk Cables
(Fixed Disk Configuration error) 2. Run Configuration/Setup
  3. Fixed Disk Adapter
  4. Fixed Disk Drive
  5. System Board
  
178X 1. Fixed Disk Cables
(Fixed Disk error) 2. Run Diagnostics
  3. Fixed Disk Adapter
  4. Fixed Disk Drive
  5. System Board
  
1800 1. Run Configuration/Setup
(No more hardware interrupt 2. Run EISA Configuration
available for PCI adapter) 3. Failing Adapter
  4. System Board
  
1801 1. Run Configuration/Setup
(No room for PCI option ROM) 2. Run EISA Configuration
  3. Failing Adapter
  4. System Board
  
1802 1. Run Configuration/Setup
(No more I/O space available 2. Failing Adapter
for PCI adapter) 3. System Board
  
1803 1. Run Configuration/Setup
(No more memory 2. Failing Adapter
(above 1 MB for PCI adapter)) 3. System Board
  
1804 1. Run Configuration/Setup
(No more memory 2. Move failing adapter to slot 1 or 2
(below 1 MB for PCI adapter)) 3. Failing Adapter
  4. System Board
  
1805 1. Remove Failing PCI Card
(PCI option ROM checksum error) 2. System Board
  
1806 1. Run Configuration/Setup
(PCI to PCI Bridge error) 2. Move failing adapter to slot 1 or 2
  3. Failing Adapter
  4. System Board
  
2400 1. Video Adapter (if installed)
(Video controller test failure) 2. System Board
  
2462 1. Video Adapter (if installed)
(Video memory configuration error) 2. System Board
  
8603 2. Pointing Device
(Pointing Device Error) 3. System Board
  
I9990301 1. Run Configuration/Setup for correct startup
(Fixed boot sector error, 2. Verify operating system installed
no operating system installed)
I9990305 1. Install operating system to hard disk drive
(Fixed boot sector error,
no operating system installed)


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.