pnt0-2 PCI search specified, PCI device not found!
Explanation: The driver
cannot locate the Ethernet controller on the PCI bus.
Action: Perform the following steps
pnt0-6 Cannot allocate memory for the adapter during an interrupt.
Please check the Streams parameters.
Explanation: The system is out of Streams memory blocks.
Action: Perform the following steps
pnt0-6 Cannot allocate memory for the adapter during an interrupt!
Please check the Streams parameters.
Explanation: On a SunSoft Solaris system, this message indicates that
the system is out of Streams memory blocks.
Action: Use the CRASH utility to
increase the number of Streams memory blocks for the failing size.
pnt0-7 Cannot allocate memory for the adapter during reset!
Please check the Streams parameters.
Explanation: The system is out of Streams memory blocks.
Action: Use the CRASH utility to
increase the number of Streams memory blocks for the failing size.
pnt0-11 device not found!
Explanation: The driver cannot find an Ethernet controller.
Action: Perform the following steps
pnt0-12 device failed checksum test!
Explanation: The driver cannot find an Ethernet controller.
Action: Perform the following steps
pnt0-13 add_intr_handler failed! Interrupts already enabled.
Explanation: The IRQ specified or found conflicts with other devices
in the system.
Action: Perform the following steps
pnt0-14 Cannot locate hardware.
Explanation: The SunSoft Solaris driver cannot find any Ethernet controller.
Action: Perform the following steps
pnt0-15 No more devices to open.
Explanation: The SunSoft Solaris driver cannot find any more
Ethernet controllers.
Action: Perform the following steps
pnt0-17 Device fault... Reset initiated!
Explanation: The SunSoft Solaris driver has been reset
due to device fault.
Action: Perform the following steps
pnt0-19
IRQ found for PCnet hardware does not match space.c!
Explanation: This is a warning message referring to the IRQ found
in the system.
Action: Ignore this message if you are sure that this is what you
want to do. Otherwise, run netconfig to match the hardware settings.
pnt0-19 IRQ found for PCnet hardware does not match pnt.conf!
Explanation: This is a warning message referring to the IRQ
that the SunSoft Solaris driver found
in the system.
Action: Ignore this message if you are sure that this is what you
want to do. Otherwise, run netconfig to match the hardware settings.
pnt0-20 add_intr_handler failed! Unknown interrupt type.
Explanation: The IRQ specified or found conflicts with other devices
in the system.
Action: Perform the following steps
pnt0-21 add_intr_handler failed! Out of range interrupt number.
Explanation: The IRQ specified or found conflicts with other devices
in the system.
Action: Perform the following steps
pnt0-23 add_intr_handler failed! Vector already occupied.
Explanation: The IRQ specified or found conflicts with other devices
in the system.
Action: Perform the following steps
pnt0-24 add_intr_handler failed! Vector already shared at different IPL.
Explanation: The IRQ specified or found conflicts with other devices
in the system.
Action: Perform the following steps
pnt0-26 The DMA number is not necessary for PCI device.
Explanation: The IBM PCI Ethernet adapter
does not require a DMA setting.
Action: Edit the SPACE.C file to delete the DMA parameter.
pnt0-29 The IRQ number is already in use by another
Explanation: The IBM PCI Ethernet adapter
Explanation: The specified IO address is already in use
pnt0-31 IO address is not necessary for the PCI device.
Explanation: The I/O address specified
is not required.
Action: Remove the assigned IO address
specified for the Ethernet controller.
Please see the LEGAL - Trademark notice.