IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
General Checkout/Diagnostics QAPlus/PRO
General Checkout/Diagnostics QAPlus/PRO
The following Maintenance Analysis Procedure (MAP) and diagnostic
information should be used to isolate problems on servers that are
supported by the QAPlus/PRO Diagnostics test.
This general checkout procedure is for computers that are supported by
the QAPlus/PRO Diagnostics test.
Diagnostic error messages appear when a test program finds a problem
with a hardware option. For the test programs to properly determine if a
test Passed , Failed , or Aborted , the test
programs check the error-return code at test completion. (See
Return Codes.)
General error messages appear if a problem or conflict is found by an
application program, the operating system, or both. For an explanation of
these messages, refer to the information supplied with that software
package.
NOTE:
- If multiple error codes are displayed, diagnose the first error code
displayed.
- If the computer reports a POST error, go to the
'Symptom-to-FRU Index' for Server 325-8639 or
'Symptom-to-FRU Index' for Server 330-8640
- If the computer hangs and no error is displayed, go to
'Undetermined Problems'
- If a device cannot be selected from the Module Test menu, that
device might be defective.
+---+
|001|
+---+
- Power-off the computer and all external devices.
- Check all cables and power cords.
- Set all display controls to the middle position.
- Insert the QAPlus/PRO Diagnostics diskette into drive A.
- Power-on all external devices.
- Power-on the computer.
- Check for the following responses.
1. One beep.
2. Readable instructions or the Main Menu.
DID YOU RECEIVE THE CORRECT RESPONSES?
+---+
Yes No |002| Find the failure symptom in the
+---+ +---+ for Server 325 see 'Symptom-to-FRU Index'
|003| for Server 330 see 'Symptom-to-FRU Index'
+---+
Run the Advanced Diagnostics Test. If necessary, refer to 'Diagnostics'.
If you receive an error, go to the
'Symptom-to-FRU Index' Server 325-8639
'Symptom-to-FRU Index' Server 330-8640
Back to
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.