| Symptom / error | FRU / action in sequence |
|---|---|
| 0200 | 1. Reseat the hard disk drive |
| Fixed disk failure | 2. Load Setup Defaults in IBM BIOS Setup Utility |
| 3. Hard disk drive | |
| 4. System board | |
| 0210, 0211 | |
| Stuck key Keyboard error | 1. Run the keyboard test in the interactive tests and auxiliary |
| input device | |
| 0212 | 1. Run the keyboard test in the interactive tests and auxiliary |
| Keyboard controller failure | input device |
| 0213 | 1. Unlock external keyboard |
| Keyboard is locked - | |
| Unlock key switch | |
| 0220 | 1. Load Setup Defaults in IBM BIOS Setup Utility |
| Monitor type does not match | |
| CMOS - run setup | |
| 0230 | 1. System board |
| Shadow RAM failure at | |
| offset nnnn | |
| 0231 | 1. DIMM |
| System RAM failure at | 2. System board |
| offset nnnn | |
| 0250 | 1. Replace the backup battery and run IBM BIOS Setup Utility to |
| System battery is dead - | reset the time and date |
| Replace and run setup | |
| 0251 | 1. Replace the backup battery and run IBM BIOS Setup Utility to |
| System CMOS checksum bad - | reset the time and date |
| Default configuration used | |
| 0260 | 1. Replace the backup battery and run IBM BIOS Setup Utility to |
| System timer error | reset the time and date |
| 2. System board | |
| 0270 | 1. Replace the backup battery and run IBM BIOS Setup Utility to |
| Real time clock error | reset the time and date |
| 2. System board | |
| 0280 | 1. Load Setup Defaults in IBM BIOS Setup Utility |
| Boot incomplete error - | 2. DIMM |
| Default configuration used | 3. System board |
| 0281 | 1. Load Setup Defaults in IBM BIOS Setup Utility |
| Memory size recognized by | 2. DIMM |
| POST is different from that | 3. System board |
| recognized by CMOS | |
| 02B0 | 1. Check that the drive is defined with the proper diskette type |
| Diskette drive error | in IBM BIOS Setup Utility |
| 2. Run the diskette diagnostics test | |
| 02D0 | 1. System board |
| System cache error - | |
| Cache is disabled | |
| 02F0 | 1. System board |
| CPU ID | |
| 02F5 | 1. DIMM |
| DIMM test failure | 2. System board |
| 02F6 | 1. DIMM |
| Software NMI failure | 2. System board |
| 02F7 | 1. DIMM |
| Fail - Safe timer NMI failure | 2. System board |
Please see the LEGAL - Trademark notice.
Feel free - send a
for any BUG on this page found - Thank you.