- Attention - Before running the PQA Diagnostic Program,
make sure that the write enable tab of the Diagnostic Program Diskette is set to enable.




PQA Diagnostic Program Error Codes and Messages
| Error Code/Message | FRU/Action in Sequence |
|---|---|
| 16XX | Backup battery |
| RTC (backup battery) error | |
| 1XXX | ° Reload BIOS default setting. |
| CPU or System board error | ° CPU board |
| ° System board | |
| 2XXX | ° Reconnect CPU board. |
| Memory error | ° DIMM |
| ° System board | |
| 3XXX | ° Reconnect keyboard. |
| Keyboard error | ° Keyboard |
| ° System board | |
| 4XXX | System board |
| Video error | |
| 5XXX | System board |
| Parallel port error | |
| 6XXX | System board |
| Serial port or | |
| system board error | |
| 7XXX | ° Diskette drive |
| Diskette drive error | ° System board |
| 8XXX | ° Load BIOS default setting |
| Hard disk error | ° Hard disk connection board |
| ° Hard disk drive | |
| 9XXX | ° Reconnect CD-ROM drive cable. |
| CD-ROM error | ° CD-ROM drive |
| ° System board | |
| 10XXX | ° CPU board |
| CPU or System board error | ° System board |
| 11XXX | ° TrackPoint board FPC cable |
| Pointing device error | ° TrackPoint board |
| ° Keyboard | |
| ° System board |