Numeric POST Error Codes and Messages
| Error Code/Message | FRU/Action in Sequence |
|---|---|
| 006 | 1. Ensure the equipment (diskette drive, hard disk drive, keyboard, |
| Equipment Configuration Error | external mouse, etc.) is connected properly and is correctly set |
| in the BIOS Utility. | |
| 2. Hard disk connection board | |
| 3. Hard disk drive | |
| 4. Planar board | |
| 010 | 1. Go to 'Memory Check'. |
| Memory Error at | 2. DIMM |
| MMMM:SSSS:OOOOh(R:xxxxh, W:xxxxh) | 3. Planar board |
| 040 | 1. Go to 'Diskette Drive Check'. |
| Diskette Drive Controller Error | 2. Ensure the diskette drive configuration setting in BIOS Utility |
| is correct. | |
| 3. Diskette drive cable | |
| 4. Diskette drive | |
| 5. Planar board | |
| 047 | 1. Ensure the diskette drive is not set to "Disabled' in the |
| Diskette Drive(s) Disabled | "System Security" menu of the BIOS Utility. |
| 2. Diskette drive cable | |
| 3. Diskette drive | |
| 050 | 1. Ensure the hard disk drive is set to "Auto' in the |
| IDE Drive 0 Error | "Basic System Settings" menu of the BIOS Utility. |
| 2. Hard disk connection board | |
| 3. Hard disk drive | |
| 4. Planar board | |
| 054 | 1. Ensure the hard disk drive is not set to "None' in the |
| IDE Drive(s) Disabled | "Basic System Settings" menu of the BIOS Utility. |
| 2. Hard disk drive cable | |
| 3. Hard disk drive | |
| 056 | 1. Ensure the hard disk drive is set to "Auto' in the |
| IDE Drive 0 Auto | "Basic System Settings" menu of the BIOS Utility. |
| Detection Failed | 2. Hard disk connection board |
| 3. Hard disk drive | |
| 4. Planar board | |
| 070 | 1. Reset time in the "Basic System Settings" menu of the BIOS Utility. |
| Real Time Clock Error | 2. Backup battery (RTC battery) |
| 3. Planar board | |
| 071 | 1. Enter BIOS Utility and execute "Load Setup Default Settings". |
| CMOS Battery Bad | 2. Backup battery (RTC battery) |
| 3. Planar board | |
| 072 | 1. Enter BIOS Utility and execute "Load Setup Default Settings", |
| CMOS Checksum Error | then reboot the system. |
| 2. Backup battery (RTC battery) | |
| 3. Planar board |
Numeric System Operation (Runtime) Error Codes and Messages
| Error Code/Message | FRU/Action in Sequence |
|---|---|
| 103 | 1. Enter BIOS Utility and execute "Load Setup Default Settings", |
| Press <Esc> to turn off | then reboot the system. |
| NMI or other key to reboot | 2. Remove the nonfactory-installed adapter card and reboot the system. |