Attention Before running the PQA Diagnostic Program,
make sure that the write enable tab of the Diagnostic Program Diskette is set to enable.




PQA Diagnostic Program Error Codes and Messages
| Error Code | Message | FRU/Action in Sequence |
|---|---|---|
| 16XX | Backup battery error | Backup battery (RTC) |
| 1XXX | CPU or planar board error | ° Reload BIOS default setting. ° CPU card ° Planar board |
| 2XXX | Memory error | ° Reconnect PU card. ° DIMM ° Planar board |
| 3XXX | Keyboard error | ° Reseat keyboard. ° Keyboard ° Planar board |
| 4XXX | Video error | Planar board |
| 5XXX | Parallel port error | Planar board |
| 6XXX | Serial port or planar board error |
Planar board |
| 7XXX | Diskette drive error | ° Diskette drive (FDD ASM) ° Planar board |
| 8XXX | Hard disk error | ° Reload BIOS default setting ° Hard disk drive ° Planar board |
| 9XXX | CD-ROM error | ° Reseat CD-ROM cable. ° CD-ROM drive ° Planar board |
| 10XXX | CPU or planar board error | ° CPU card ° Planar board |
| 11XXX | Pointing device error | ° Reseat keyboard. ° Keyboard ° Planar board |