| Symptom/Error | FRU/Action in Sequence |
|---|---|
| 0200 | 1. Reseat hard disk drive. |
| Failure Fixed Disk | 2. Load Setup Defaults in BIOS Setup Utility. |
| 3. Hard disk drive | |
| 4. System board | |
| 0211 | Go to 'Keyboard and Auxiliary Input Device Checkout'. |
| Stuck Key | |
| 0211 | Go to 'Keyboard and Auxiliary Input Device Checkout'. |
| Keyboard error | |
| 0212 | Go to 'Keyboard and Auxiliary Input Device Checkout'. |
| Keyboard Controller | |
| Failed | |
| 0213 | Unlock external keyboard. |
| Keyboard locked - | |
| Unlock key switch | |
| 0220 | Load Setup Defaults in BIOS Setup Utility. |
| Monitor type does not | |
| match CMOS - Run Setup | |
| 0230 | System board |
| Shadow RAM Failed | |
| at offset:nnnn | |
| 0231 | 1. DIMM |
| System RAM Failed | 2. System board |
| at offset:nnnn | |
| 0232 | 1. DIMM |
| Extended RAM Failed | 2. System board |
| at offset:nnnn | |
| 0250 | System board |
| System battery is dead | |
| 0251 | System board |
| System CMOS checksum bad - | |
| Default configuration used | |
| 0260 | 1. Run BIOS Setup Utility to reconfigure the system, |
| System timer error | then reboot the system. |
| 2. System board | |
| 0270 | 1. Run BIOS Setup Utility to reconfigure the system, then reboot the system. |
| Real time clock error | 2. System board |
| 0280 | 1. Load Setup Defaults in the BIOS Setup Utility. |
| Previous boot incomplete - | 2. System board |
| Default configuration used | |
| 0281 | 1. Load Setup Defaults in the BIOS Setup Utility. |
| Memory size found by | 2. DIMM |
| POST differed from CMOS | 3. System board |
| 02D0 | System board |
| - Cache disabled | |
| System cache error | |
| 02F0 | System board |
| CPU ID: | |
| 02F5 | 1. DIMM |
| DMA Test Failed | 2. System board |
| 02F6 | 1. DIMM |
| Software NMI Failed | 2. System board |
| 02F7 | 1. DIMM |
| Fail-Safe Timer | 2. System board |
| NMI Failed |