Numeric Error Codes
| Symptom / Error | FRU / Action in Sequence |
|---|---|
| 10X | 1. System Board |
| 101 Interrupt failure. | |
| 102 Timer failure. | |
| 103 Timer interrupt failure. | |
| 104 Protected mode failure. | |
| 105 Last 8042 command not accepted. | |
| 107 NMI test failure. | |
| 108 Timer bus test failure. | |
| 109 Low meg-chip select test. | |
| 110 | 1. Go to 'Memory Checkout' |
| (Planar parity.) | 2. DIMM |
| 3. The computer is attached to the expansion unit. | |
| 4. System Board | |
| 111 | 1. Go to 'Memory Checkout' |
| (I/O parity.) | 2. Expansion Unit or Port Replicator |
| 3. System Board | |
| 158 | 1. Set an HDPs for the both hard disk drive. |
| (HDP was not set even though | in the HDD bay and one in the UltraBay |
| the supervisor password is set.) | |
| 159 | 1. Set a HDPs for both the hard disk drive. |
| (HDP is not set the same | in the HDD bay and one in the UltraBay |
| as the supervisor password.) | |
| 161 | 1. Go to 'Checking the Backup Battery'. |
| (Dead battery.) | 2. Backup Battery |
| 3. System Board | |
| 163 | 1. Reseat the keyboard connector on |
| (Time and Date were not set.) | the video card. |
| (Time and Date were not set.) | 2. Set Time and Date |
| 3. System Board | |
| 173 | 1. Reseat the keyboard connector on |
| (Configuration data was lost.) | the video card. |
| 2. Select OK in the error screen, | |
| then set the time and date | |
| 3. Backup Battery | |
| 4. System Board | |
| 174 | 1. Check Device Configuration. |
| (Configuration error: Perform | 2. System Board |
| 'Checking the Installed Devices List' | 3. Diskette Drive Assembly |
| before changing any FRUs.) | 4. Hard Disk Drive Assembly |
| 175, 177, 178 | 1. System Board |
| 175 EEPROM CRC #1 error. | |
| 177 Supervisor password check sum error. | |
| 178 EEPROM is not functional. | |
| 183 | 1. Have the user examine the password. |
| (Incorrect password entered | |
| at the supervisor | |
| password prompt.) | |
| 184 | 1. Reset the POP (power-on password) in Easy-Setup. |
| (POP check sum error.) | |
| 185 | 1. Reset the startup sequence |
| (The startup sequence is not | in Easy-Setup. |
| valid. Suspect that power was | |
| off when the startup sequence | |
| was being updated.) | |
| 186 | 1. System Board |
| 188 | 1. Set the system identification |
| (EEPROM CRC #2 error.) | using the ThinkPad Hardware Maint. |
| Diskette Vers. 1.30 | |
| 190 | 1. Go to 'Checking the Battery Pack' |
| (Depleted battery pack was | |
| installed when the power was on.) | |
| 191XX | 1. System Board |
| (PM initialization error.) | 2. CPU card |
| 195 | 1. Check if the configuration was changed. |
| (The configuration read | For example, check if the DIMM is added or disk drive |
| from the hibernation area | is from another computer |
| does not match the | |
| actual configuration.) | |
| 196 | 1. Run the hard disk drive test. |
| (Read error occurred in the | 2. Hard Disk Drive |
| hibernation area of the HDD.) | |
| 1XX | 1. System Board |
| 2XX | 1. Go to 'Memory Checkout'. |
| 201 Memory data error. | 2. DIMM or DIMM adapter |
| 202 Memory line error 00-15. | 3. System Board |
| 203 Memory line error 16-23. | |
| 205 Memory test failure on on-board memory. | |
| 221 ROM to RAM remap error. | |
| 301, 303, 304, 305, 3XX | 1. Go to 'Keyboard/Aux. Input Device Checkout' |
| (301: Keyboard error.) | 2. Keyboard |
| 3. Video card | |
| 4. External Numeric Keypad | |
| 5. External Keyboard | |
| 6. Keyboard/Mouse Cable | |
| 7. System Board | |
| 601, 6XX | 1. Go to 'Diskette Drive Checkout'. |
| (601: Diskette drive | 2. Diskette Drive |
| or controller error.) | 3. Diskette |
| 4. System Board | |
| 602 | 1. Go to 'Diskette Drive Checkout'. |
| (Diskette read error.) | 2. Diskette |
| 3. Diskette Drive | |
| 604 | 1. Go to 'Diskette Drive Checkout'. |
| (Unacceptable ID was read | 2. Diskette Drive |
| from the diskette drive.) | 3. System Board |
| 11XX | 1. Serial Device |
| 1101: Serial_A test failure. | 2. Communication Cable |
| 3. System Board | |
| 17XX | 1. Hard Disk Drive |
| 1701 Hard disk controller failure. | 2. System Board |
| 1780, 1790 Hard disk 0 error. | |
| 1781, 1791 Hard disk 1 error. | |
| 24XX | 1. System Board |
| (2401: System board video error.) | |
| 808X | 1. PCMCIA slot Assembly. |
| 8081 PCMCIA presence | 2. PCMCIA device |
| test failure. | 3. System Board |
| (PCMCIA revision number | |
| also checked.) | |
| 8082 PCMCIA register | |
| test failure. | |
| 860X | 1. External Mouse |
| (Pointing device error | 2. External Keyboard |
| when TrackPoint III is | 3. System Board |
| disabled.) | |
| 8601 System bus error-8042 | |
| mouse interface. | |
| 8602 External mouse error. | |
| 8603 System bus error or mouse error. | |
| 861X | 1. Reseat the keyboard connector. |
| (Pointing device error | on the video card. |
| when TrackPoint III is enabled.) | 2. Reseat the keyboard TrackPoint III |
| 8611 System bus error-I/F | cable on the keyboard card. |
| between 8042 and IPDC. | See '1070 Keyboard Unit'. |
| 8612 TrackPoint error. | 3. Keyboard |
| 8613 System board or | 4. External Mouse |
| TrackPoint error. | 5. 4System Board |
| I9990301 | 1. Check that the operating system is |
| I9990302 | installed in the HDD. If not, install |
| I9990305 | the operating system. |
| I9990301 Hard disk error. | 2. Reseat the boot device |
| I9990302 Invalid hard disk | 3. Check the startup sequence for |
| boot record. | the correct boot device. |
| I9990305 No bootable device. | 4. Check that the operating system has |
| no failure and is installed correctly. | |
| I9990303 | 1. System Board |
| (Bank 2 flash ROM check sum error.) | |
| Other codes not listed above | 1. Go to 'Undetermined Problems'. |
Please see the LEGAL - Trademark notice.