| Symptom/Error | FRU/Action |
|---|---|
| 10X | 1. System Board |
| 101 Interrupt failure | |
| 102 Timer failure | |
| 103 Timer interrupt failure | |
| 104 Protected mode failure | |
| 105 Last 8042 command- | |
| -not accepted | |
| 107 NMI test failure | |
| 108 Timer bus test failure | |
| 109 Low meg-chip select test | |
| 110 | 1. Go to 'Memory Checkout' |
| 2. DIMM Card | |
| 3. The computer is attached to the expansion unit | |
| 4. System Board | |
| 111 | 1. Go to 'Memory Checkout' |
| 2. System Board | |
| 161 | 1. Go to 'Checking the Backup Battery' |
| (Dead battery) | 2. Backup Battery |
| 3. System Board | |
| 163 | 1. Reseat the keyboard connector |
| (Time and Date was not set.) | on the system board |
| 2. Set Time and Date | |
| 3. System Board | |
| 173 | 1. Reseat the keyboard connector |
| (Configuration data were lost.) | on the system board |
| 2. Select OK in the error screen, | |
| then set time and date. | |
| 3. Backup Battery | |
| 4. System Board | |
| 174 | 1. Check Device Configuration. |
| Configuration error (Perform | 2. System Board |
| 'Checking the Installed Devices List' | 3. Diskette Drive Assembly |
| before changing any FRUs.) | 4. Hard Disk Drive Assembly |
| 184 | 1. Reset the POP in Easy-Setup. |
| (POP check sum error.) | |
| 190 | 1. Go to 'Checking the Battery Pack' |
| (A depleted battery pack was | |
| installed when the power was on.) | |
| 191XX | 1. System Board |
| (PM initialzation error) | |
| 195 | 1. Check if the configuration |
| (The configuration read from the | was changed |
| hibernation area does not match | For example, check if the DIMM card |
| the actual configuration.) | is added. |
| 196 | 1. Run the hard disk drive test |
| (Read error occured in the | 2. Hard Disk Drive |
| hibernation area of the HDD.) | |
| 1XX | 1. System Board |
| 2XX | 1. Go to 'Memory Checkout' |
| 201 Memory data error | 2. DIMM Card |
| 202 Memory line error 00-15 | 3. System Board |
| 203 Memory line error 16-23 | |
| 205 Memory test failure on | |
| on-board memory | |
| 221 ROM to RAM remap error | |
| 301, 303, 304, 305, 3XX | 1. Go to 'Keyboard / Auxiliary Input Device Checkout' |
| (Keyboard error) | 2. Keyboard |
| 3. External Numeric Keypad | |
| 4. External Keyboard | |
| 5. Keyboard/Mouse Cable | |
| 6. System Board | |
| 601, 6XX | 1. Go to 'Diskette Drive Test' |
| (Diskette drive or | 2. Diskette Drive Assembly |
| controller error.) | 3. Diskette |
| 4. System Board | |
| 602 | 1. Go to 'Diskette Drive Test' |
| (Diskette read error.) | 2. Diskette |
| 3. Diskette Drive Assembly | |
| 604 | 1. Go to 'Diskette Drive Test' |
| (Non-acceptable ID was read | 2. Diskette Drive Assembly |
| from the diskette drive.) | 3. System Board |
| 11XX | 1. Serial Device (First) |
| 1101 Serial A test failure | 2. Communication Cable |
| 3. System Board | |
| 12XX | 1. System Board (Infrared) |
| 1101 Serial B test failure | |
| 17XX | 1. Hard Disk Drive |
| 1701 Hard sisk controller failure | 2. System Board |
| 1780, 1790 Hard disk 0 error | |
| 1781, 1791 Hard disk 1 error | |
| 24XX | 1. System Board |
| 2401 System board video error | |
| 808X | 1. PCMCIA Slot Assembly |
| 8081 PCMCIA presence test failure | 2. PCMCIA Device |
| (PCMCIA revision also checked) | 3. System Board |
| 8082 PCMCIA register test failure | |
| 860X | 1. External Mouse |
| (Pointing device error when | 2. External Keyboard |
| TrackPoint III is disabled.) | 3. System Board |
| 8601 Systembus error- | |
| 8042 mouse interface | |
| 8602 External mouse error | |
| 8603 System bus error or | |
| mouse error | |
| 861X | 1. Reseat the keyboard cable on |
| (Pointing device error when | the systemboard. |
| TrackPoint III is enabled.) | 2. Keyboard |
| 8611 System bus error-I/F between | 3. External Mouse |
| 8042 and IPDC | 4. System Board |
| 8612 TrackPoint error | |
| 8613 System board or TrackPoint error. | |
| I9990301 | 1. Check that the operating system. |
| I9990302 | is installed in the HDD. |
| I9990305 | If not, install the operating system. |
| I9990301 Hard disk error | 2. Reseat the boot device |
| I9990302 Invalid hard disk boot | 3. Check the startup sequence for the correct |
| record. | boot device. |
| I9990305 No bootable device | 4. Check that the operating system has no |
| failure and is installed correctly | |
| I9990303 | 1. System Board |
| Bank-2 flash ROM checksum error | |
| Other codes not listed above | 1. Go to 'Undetermined Problems' |
Please see the LEGAL - Trademark notice.
Feel free - send a
for any BUG on this page found - Thank you.